The RENEB operational basis: complement of established biodosimetric assays

Standard

The RENEB operational basis: complement of established biodosimetric assays. / Wojcik, Andrzej; Oestreicher, Ursula; Barrios, Lleonard; Vral, Anne; Terzoudi, Georgia; Ainsbury, Elizabeth; Rothkamm, Kai; Trompier, Francois; Kulka, Ulrike.

In: INT J RADIAT BIOL, Vol. 93, No. 1, 01.2017, p. 15-19.

Research output: SCORING: Contribution to journalSCORING: Journal articleResearchpeer-review

Harvard

Wojcik, A, Oestreicher, U, Barrios, L, Vral, A, Terzoudi, G, Ainsbury, E, Rothkamm, K, Trompier, F & Kulka, U 2017, 'The RENEB operational basis: complement of established biodosimetric assays', INT J RADIAT BIOL, vol. 93, no. 1, pp. 15-19. https://doi.org/10.1080/09553002.2016.1235296

APA

Wojcik, A., Oestreicher, U., Barrios, L., Vral, A., Terzoudi, G., Ainsbury, E., Rothkamm, K., Trompier, F., & Kulka, U. (2017). The RENEB operational basis: complement of established biodosimetric assays. INT J RADIAT BIOL, 93(1), 15-19. https://doi.org/10.1080/09553002.2016.1235296

Vancouver

Wojcik A, Oestreicher U, Barrios L, Vral A, Terzoudi G, Ainsbury E et al. The RENEB operational basis: complement of established biodosimetric assays. INT J RADIAT BIOL. 2017 Jan;93(1):15-19. https://doi.org/10.1080/09553002.2016.1235296

Bibtex

@article{d7c3fa481217470fb58680bad9e37369,
title = "The RENEB operational basis: complement of established biodosimetric assays",
abstract = "PURPOSE: To set up an operational basis of the Realizing the European Network of Biodosimetry (RENEB) network within which the application of seven established biodosimetric tools (the dicentric assay, the FISH assay, the micronucleus assay, the PCC assay, the gamma-H2AX assay, electron paramagnetic resonance and optically stimulated luminescence) will be compared and standardized among the participating laboratories.METHODOLOGY: Two intercomparisons were organized where blood samples and smartphone components were irradiated, coded and sent out to participating laboratories for dosimetric analysis. Moreover, an accident exercise was organized during which each RENEB partner had the chance to practice the procedure of activating the network and to handle large amounts of dosimetric results.RESULTS: All activities were carried out as planned. Overall, the precision of dose estimates improved between intercomparisons 1 and 2, clearly showing the value of running such regular activities.CONCLUSIONS: The RENEB network is fully operational and ready to act in case of a major radiation emergency. Moreover, the high capacity for analyzing radiation-induced damage in cells and personal electronic devices makes the network suitable for large-scale analyses of low doses effects, where high numbers of samples must be scored in order to detect weak effects.",
author = "Andrzej Wojcik and Ursula Oestreicher and Lleonard Barrios and Anne Vral and Georgia Terzoudi and Elizabeth Ainsbury and Kai Rothkamm and Francois Trompier and Ulrike Kulka",
year = "2017",
month = jan,
doi = "10.1080/09553002.2016.1235296",
language = "English",
volume = "93",
pages = "15--19",
journal = "INT J RADIAT BIOL",
issn = "0955-3002",
publisher = "Taylor & Francis",
number = "1",

}

RIS

TY - JOUR

T1 - The RENEB operational basis: complement of established biodosimetric assays

AU - Wojcik, Andrzej

AU - Oestreicher, Ursula

AU - Barrios, Lleonard

AU - Vral, Anne

AU - Terzoudi, Georgia

AU - Ainsbury, Elizabeth

AU - Rothkamm, Kai

AU - Trompier, Francois

AU - Kulka, Ulrike

PY - 2017/1

Y1 - 2017/1

N2 - PURPOSE: To set up an operational basis of the Realizing the European Network of Biodosimetry (RENEB) network within which the application of seven established biodosimetric tools (the dicentric assay, the FISH assay, the micronucleus assay, the PCC assay, the gamma-H2AX assay, electron paramagnetic resonance and optically stimulated luminescence) will be compared and standardized among the participating laboratories.METHODOLOGY: Two intercomparisons were organized where blood samples and smartphone components were irradiated, coded and sent out to participating laboratories for dosimetric analysis. Moreover, an accident exercise was organized during which each RENEB partner had the chance to practice the procedure of activating the network and to handle large amounts of dosimetric results.RESULTS: All activities were carried out as planned. Overall, the precision of dose estimates improved between intercomparisons 1 and 2, clearly showing the value of running such regular activities.CONCLUSIONS: The RENEB network is fully operational and ready to act in case of a major radiation emergency. Moreover, the high capacity for analyzing radiation-induced damage in cells and personal electronic devices makes the network suitable for large-scale analyses of low doses effects, where high numbers of samples must be scored in order to detect weak effects.

AB - PURPOSE: To set up an operational basis of the Realizing the European Network of Biodosimetry (RENEB) network within which the application of seven established biodosimetric tools (the dicentric assay, the FISH assay, the micronucleus assay, the PCC assay, the gamma-H2AX assay, electron paramagnetic resonance and optically stimulated luminescence) will be compared and standardized among the participating laboratories.METHODOLOGY: Two intercomparisons were organized where blood samples and smartphone components were irradiated, coded and sent out to participating laboratories for dosimetric analysis. Moreover, an accident exercise was organized during which each RENEB partner had the chance to practice the procedure of activating the network and to handle large amounts of dosimetric results.RESULTS: All activities were carried out as planned. Overall, the precision of dose estimates improved between intercomparisons 1 and 2, clearly showing the value of running such regular activities.CONCLUSIONS: The RENEB network is fully operational and ready to act in case of a major radiation emergency. Moreover, the high capacity for analyzing radiation-induced damage in cells and personal electronic devices makes the network suitable for large-scale analyses of low doses effects, where high numbers of samples must be scored in order to detect weak effects.

U2 - 10.1080/09553002.2016.1235296

DO - 10.1080/09553002.2016.1235296

M3 - SCORING: Journal article

C2 - 27778526

VL - 93

SP - 15

EP - 19

JO - INT J RADIAT BIOL

JF - INT J RADIAT BIOL

SN - 0955-3002

IS - 1

ER -