Response of radiation protection dosemeters in mixed high-energy photon and electron radiation fields.

Standard

Response of radiation protection dosemeters in mixed high-energy photon and electron radiation fields. / Büermann, L; Gargioni, Elisabetta; Kramer, H M.

In: RADIAT PROT DOSIM, Vol. 96, No. 1-3, 1-3, 2001, p. 223-226.

Research output: SCORING: Contribution to journalSCORING: Journal articleResearchpeer-review

Harvard

APA

Vancouver

Bibtex

@article{40f2d1cf6aca4da281972357d5bed521,
title = "Response of radiation protection dosemeters in mixed high-energy photon and electron radiation fields.",
abstract = "The response of radiation protection dosemeters in terms of the phantom-related operational quantities Hp(10) and H'(10.0 degrees) was measured for personal and area monitoring systems in mixed high-energy electron and photon radiation fields with energies up to 7 MeV. Using mixed radiation fields composed of different fractions of charged particle and photon fluence, three conditions were produced at the point of measurement: charged particle equilibrium (CPE) (a), a lack (b) and an excess (c) of charged particles relative to the conditions of CPE. Personal and area dosemeters of different types were investigated under conditions (a)-(c). A large variability of the response of the different dosemeter types was observed. The results are presented and discussed.",
author = "L B{\"u}ermann and Elisabetta Gargioni and Kramer, {H M}",
year = "2001",
language = "Deutsch",
volume = "96",
pages = "223--226",
journal = "RADIAT PROT DOSIM",
issn = "0144-8420",
publisher = "Oxford University Press",
number = "1-3",

}

RIS

TY - JOUR

T1 - Response of radiation protection dosemeters in mixed high-energy photon and electron radiation fields.

AU - Büermann, L

AU - Gargioni, Elisabetta

AU - Kramer, H M

PY - 2001

Y1 - 2001

N2 - The response of radiation protection dosemeters in terms of the phantom-related operational quantities Hp(10) and H'(10.0 degrees) was measured for personal and area monitoring systems in mixed high-energy electron and photon radiation fields with energies up to 7 MeV. Using mixed radiation fields composed of different fractions of charged particle and photon fluence, three conditions were produced at the point of measurement: charged particle equilibrium (CPE) (a), a lack (b) and an excess (c) of charged particles relative to the conditions of CPE. Personal and area dosemeters of different types were investigated under conditions (a)-(c). A large variability of the response of the different dosemeter types was observed. The results are presented and discussed.

AB - The response of radiation protection dosemeters in terms of the phantom-related operational quantities Hp(10) and H'(10.0 degrees) was measured for personal and area monitoring systems in mixed high-energy electron and photon radiation fields with energies up to 7 MeV. Using mixed radiation fields composed of different fractions of charged particle and photon fluence, three conditions were produced at the point of measurement: charged particle equilibrium (CPE) (a), a lack (b) and an excess (c) of charged particles relative to the conditions of CPE. Personal and area dosemeters of different types were investigated under conditions (a)-(c). A large variability of the response of the different dosemeter types was observed. The results are presented and discussed.

M3 - SCORING: Zeitschriftenaufsatz

VL - 96

SP - 223

EP - 226

JO - RADIAT PROT DOSIM

JF - RADIAT PROT DOSIM

SN - 0144-8420

IS - 1-3

M1 - 1-3

ER -