Analyse der Passgenauigkeit der Prothesenköpfe der Ascension® PyroCarbon-Fingermittelgelenksprothese
Standard
Analyse der Passgenauigkeit der Prothesenköpfe der Ascension® PyroCarbon-Fingermittelgelenksprothese. / Ries, C; Zhang, W; Müller, L P; Hohendorff, B.
In: HANDCHIR MIKROCHIR P, Vol. 47, No. 5, 10.2015, p. 322-7.Research output: SCORING: Contribution to journal › SCORING: Journal article › Research › peer-review
Harvard
APA
Vancouver
Bibtex
}
RIS
TY - JOUR
T1 - Analyse der Passgenauigkeit der Prothesenköpfe der Ascension® PyroCarbon-Fingermittelgelenksprothese
AU - Ries, C
AU - Zhang, W
AU - Müller, L P
AU - Hohendorff, B
N1 - © Georg Thieme Verlag KG Stuttgart · New York.
PY - 2015/10
Y1 - 2015/10
N2 - BACKGROUND: The Ascension pyroCarbon proximal interphalangeal (PIP) total joint is available in 4 different sizes, and ideally, the prosthesis head will be flush with the bone. Fit of the Ascension pyrocarbon PIP joint prosthesis has not yet been investigated.MATERIALS AND METHODS: The components of the Ascension pyrocarbon PIP total joint were inserted in 287 phalanges of human cadaver specimens. The distances from the edge of the component head to the edge of the bone were electronically measured radially, ulnarly, dorsally and palmarly on radiographs in posterior-anterior and lateral views.RESULTS: Only one finger had a precise fit of the heads of both, the proximal and corresponding distal component in relation to the bone. Only in 17 (5 proximal, 12 distal) prosthesis components the head did the bone fit on all sides. Overall, the proximal component head tends to be too large, while the distal component head tends to be too small.CONCLUSION: With occasional exceptions, the proximal and distal component heads of the Ascension pyrocarbon PIP total joint do not accomodate the dimensions of finger phalanges.
AB - BACKGROUND: The Ascension pyroCarbon proximal interphalangeal (PIP) total joint is available in 4 different sizes, and ideally, the prosthesis head will be flush with the bone. Fit of the Ascension pyrocarbon PIP joint prosthesis has not yet been investigated.MATERIALS AND METHODS: The components of the Ascension pyrocarbon PIP total joint were inserted in 287 phalanges of human cadaver specimens. The distances from the edge of the component head to the edge of the bone were electronically measured radially, ulnarly, dorsally and palmarly on radiographs in posterior-anterior and lateral views.RESULTS: Only one finger had a precise fit of the heads of both, the proximal and corresponding distal component in relation to the bone. Only in 17 (5 proximal, 12 distal) prosthesis components the head did the bone fit on all sides. Overall, the proximal component head tends to be too large, while the distal component head tends to be too small.CONCLUSION: With occasional exceptions, the proximal and distal component heads of the Ascension pyrocarbon PIP total joint do not accomodate the dimensions of finger phalanges.
KW - Aged
KW - Aged, 80 and over
KW - Arthroplasty, Replacement/methods
KW - Carbon
KW - Female
KW - Finger Joint/diagnostic imaging
KW - Humans
KW - Male
KW - Middle Aged
KW - Prosthesis Design
KW - Prosthesis Failure
KW - Prosthesis Fitting
KW - Radiography
U2 - 10.1055/s-0035-1555867
DO - 10.1055/s-0035-1555867
M3 - SCORING: Zeitschriftenaufsatz
C2 - 26221758
VL - 47
SP - 322
EP - 327
JO - HANDCHIR MIKROCHIR P
JF - HANDCHIR MIKROCHIR P
SN - 0722-1819
IS - 5
ER -