Validation of pulse contour derived stroke volume variation during modifications of cardiac afterload.
Standard
Validation of pulse contour derived stroke volume variation during modifications of cardiac afterload. / Kubitz, Jens; Annecke, T; Forkl, S; Kemming, G I; Kronas, Nils; Goetz, A E; Reuter, Daniel.
in: BRIT J ANAESTH, Jahrgang 98, Nr. 5, 5, 2007, S. 591-597.Publikationen: SCORING: Beitrag in Fachzeitschrift/Zeitung › SCORING: Zeitschriftenaufsatz › Forschung › Begutachtung
Harvard
APA
Vancouver
Bibtex
}
RIS
TY - JOUR
T1 - Validation of pulse contour derived stroke volume variation during modifications of cardiac afterload.
AU - Kubitz, Jens
AU - Annecke, T
AU - Forkl, S
AU - Kemming, G I
AU - Kronas, Nils
AU - Goetz, A E
AU - Reuter, Daniel
PY - 2007
Y1 - 2007
N2 - BACKGROUND: Left ventricular stroke volume variation (SVV) or its surrogates are useful tools to assess fluid responsiveness in mechanically ventilated patients. So far it is unknown, how changes in cardiac afterload affect SVV. Therefore, this study compared left ventricular SVV derived by pulse contour analysis with SVV measured using an ultrasonic flow probe and investigated the influence of cardiac afterload on left ventricular SVV. METHODS: In 13 anaesthetized, mechanically ventilated pigs [31(SD 6) kg], we compared cardiac output (CO), stroke volume (SV), and SVV determined by pulse contour analysis and by an ultrasonic aortic flow signal (Bland-Altman analysis). After obtaining baseline measurements, cardiac afterload was increased using phenylephrine and decreased using adenosine (both continuously administered). Measurements were performed with a constant tidal volume (12 ml kg-1) without PEEP. RESULTS: Neither increasing mean arterial pressure (MAP) [from 59 (7) to 116 (19)] nor decreasing MAP [from 63 (7) to 39 (4)] affected CO, SV, and SVV (both methods). Method comparison revealed a bias for SVV of 0.1% [standard error of the mean (SE) 0.8] at baseline, -1.2% (SE 0.8) during decreased and 4.0% (SE 0.7) during increased afterload, the latter being significantly different from the others (P
AB - BACKGROUND: Left ventricular stroke volume variation (SVV) or its surrogates are useful tools to assess fluid responsiveness in mechanically ventilated patients. So far it is unknown, how changes in cardiac afterload affect SVV. Therefore, this study compared left ventricular SVV derived by pulse contour analysis with SVV measured using an ultrasonic flow probe and investigated the influence of cardiac afterload on left ventricular SVV. METHODS: In 13 anaesthetized, mechanically ventilated pigs [31(SD 6) kg], we compared cardiac output (CO), stroke volume (SV), and SVV determined by pulse contour analysis and by an ultrasonic aortic flow signal (Bland-Altman analysis). After obtaining baseline measurements, cardiac afterload was increased using phenylephrine and decreased using adenosine (both continuously administered). Measurements were performed with a constant tidal volume (12 ml kg-1) without PEEP. RESULTS: Neither increasing mean arterial pressure (MAP) [from 59 (7) to 116 (19)] nor decreasing MAP [from 63 (7) to 39 (4)] affected CO, SV, and SVV (both methods). Method comparison revealed a bias for SVV of 0.1% [standard error of the mean (SE) 0.8] at baseline, -1.2% (SE 0.8) during decreased and 4.0% (SE 0.7) during increased afterload, the latter being significantly different from the others (P