Robotic versus conventional ablation for common-type atrial flutter: a prospective randomized trial to evaluate the effectiveness of remote catheter navigation
Standard
Robotic versus conventional ablation for common-type atrial flutter: a prospective randomized trial to evaluate the effectiveness of remote catheter navigation. / Steven, Daniel; Rostock, Thomas; Servatius, Helge; Hoffmann, Boris; Drewitz, Imke; Müllerleile, Kai; Meinertz, Thomas; Willems, Stephan.
in: HEART RHYTHM, Jahrgang 5, Nr. 11, 11.2008, S. 1556-1560.Publikationen: SCORING: Beitrag in Fachzeitschrift/Zeitung › SCORING: Zeitschriftenaufsatz › Forschung › Begutachtung
Harvard
APA
Vancouver
Bibtex
}
RIS
TY - JOUR
T1 - Robotic versus conventional ablation for common-type atrial flutter: a prospective randomized trial to evaluate the effectiveness of remote catheter navigation
AU - Steven, Daniel
AU - Rostock, Thomas
AU - Servatius, Helge
AU - Hoffmann, Boris
AU - Drewitz, Imke
AU - Müllerleile, Kai
AU - Meinertz, Thomas
AU - Willems, Stephan
PY - 2008/11
Y1 - 2008/11
N2 - BACKGROUND: Conventional catheter ablation for common-type atrial flutter (AFL) is a widely established therapy but has not been compared with the use of a robotic navigation system (RNS) thus far.OBJECTIVES: The purpose of this study was to investigate the feasibility of a new, nonmagnetic RNS with regard to safety, efficacy, and X-ray exposure to investigator and patient compared with the conventional ablation approach in patients with AFL.METHODS: Fifty patients (65.7 +/- 9.3 years, 40 male) undergoing de novo catheter ablation for AFL were randomly assigned to conventional or RNS-guided cavotricuspid isthmus (CTI) ablation.RESULTS: Complete bidirectional isthmus block was achieved for all patients without occurrence of procedure-related complications. The fluoroscopy time and the investigator X-ray exposure (8.2 +/- 4.6 vs. 5.8 +/- 3.6, P = .038; and 8.2 +/- 4.6 vs. 1.9 +/- 1.1 minutes, P<.001) as well as the mean radiofrequency (RF) duration and the energy delivered were significantly higher in the conventional than in the RNS group (321.7 +/- 214.6 vs. 496.4 +/- 213.9 seconds, P = .006; 8279 +/- 5767 vs. 16,308 +/- 6870 J, P<.001, respectively). The overall procedure time in the RNS group was significantly longer than in the conventional group (79.2 +/- 30.6 vs. 58.4 +/- 17.7 minutes; P = .04) but significantly decreased comparing the first 10 with the last 10 patients in the RNS group (105.3 +/- 34.8 vs. 60.6 +/- 6.3 minutes; P = .003). Starting ablation during AFL, bidirectional block instantly after termination was observed in 90% of the RNS and 50% of the conventionally treated patients (P = .03).CONCLUSION: The present study demonstrates the safety and feasibility of RNS for performing CTI ablation in patients with common-type AFL for use in the clinical routine. As a result of the remote navigation, X-ray exposure and RF duration to achieve bidirectional block were significantly decreased and occurred more often immediately after AFL termination. These findings are consistent with increased catheter stability and RF application efficacy using RNS compared with conventional catheter manipulation.
AB - BACKGROUND: Conventional catheter ablation for common-type atrial flutter (AFL) is a widely established therapy but has not been compared with the use of a robotic navigation system (RNS) thus far.OBJECTIVES: The purpose of this study was to investigate the feasibility of a new, nonmagnetic RNS with regard to safety, efficacy, and X-ray exposure to investigator and patient compared with the conventional ablation approach in patients with AFL.METHODS: Fifty patients (65.7 +/- 9.3 years, 40 male) undergoing de novo catheter ablation for AFL were randomly assigned to conventional or RNS-guided cavotricuspid isthmus (CTI) ablation.RESULTS: Complete bidirectional isthmus block was achieved for all patients without occurrence of procedure-related complications. The fluoroscopy time and the investigator X-ray exposure (8.2 +/- 4.6 vs. 5.8 +/- 3.6, P = .038; and 8.2 +/- 4.6 vs. 1.9 +/- 1.1 minutes, P<.001) as well as the mean radiofrequency (RF) duration and the energy delivered were significantly higher in the conventional than in the RNS group (321.7 +/- 214.6 vs. 496.4 +/- 213.9 seconds, P = .006; 8279 +/- 5767 vs. 16,308 +/- 6870 J, P<.001, respectively). The overall procedure time in the RNS group was significantly longer than in the conventional group (79.2 +/- 30.6 vs. 58.4 +/- 17.7 minutes; P = .04) but significantly decreased comparing the first 10 with the last 10 patients in the RNS group (105.3 +/- 34.8 vs. 60.6 +/- 6.3 minutes; P = .003). Starting ablation during AFL, bidirectional block instantly after termination was observed in 90% of the RNS and 50% of the conventionally treated patients (P = .03).CONCLUSION: The present study demonstrates the safety and feasibility of RNS for performing CTI ablation in patients with common-type AFL for use in the clinical routine. As a result of the remote navigation, X-ray exposure and RF duration to achieve bidirectional block were significantly decreased and occurred more often immediately after AFL termination. These findings are consistent with increased catheter stability and RF application efficacy using RNS compared with conventional catheter manipulation.
KW - Aged
KW - Atrial Flutter/surgery
KW - Catheter Ablation/instrumentation
KW - Equipment Design
KW - Female
KW - Heart Conduction System/surgery
KW - Humans
KW - Male
KW - Middle Aged
KW - Prospective Studies
KW - Robotics
KW - Treatment Outcome
U2 - 10.1016/j.hrthm.2008.08.028
DO - 10.1016/j.hrthm.2008.08.028
M3 - SCORING: Journal article
C2 - 18984532
VL - 5
SP - 1556
EP - 1560
JO - HEART RHYTHM
JF - HEART RHYTHM
SN - 1547-5271
IS - 11
ER -