Phenotyping heterozygous carriers of juvenile neuronal ceroid lipofuscinosis with CLN3 mutations

Standard

Phenotyping heterozygous carriers of juvenile neuronal ceroid lipofuscinosis with CLN3 mutations. / Bergholz, Richard; Kohlschütter, Alfried; Schulz, Angela; Hubert, Waltraud; Rüther, Klaus.

in: GRAEF ARCH CLIN EXP, Jahrgang 253, Nr. 8, 08.2015, S. 1245-1250.

Publikationen: SCORING: Beitrag in Fachzeitschrift/ZeitungSCORING: ZeitschriftenaufsatzForschungBegutachtung

Harvard

APA

Vancouver

Bibtex

@article{7aaa84fbba254f6cace318295f917fb2,
title = "Phenotyping heterozygous carriers of juvenile neuronal ceroid lipofuscinosis with CLN3 mutations",
abstract = "PURPOSE: The objective of this study was to establish an ophthalmologic phenotype of heterozygous carriers of juvenile neuronal ceroid lipofuscinosis (CLN3 disease, Batten disease).METHODS: The eyes and vision of nine heterozygous carriers of juvenile neuronal ceroid lipofuscinosis with classical CLN3 mutations were examined using the following methods: clinical examination, visual acuity, ophthalmoscopy, optical coherence tomography (macular thickness and peripapillary retinal nerve fibre layer measurement [RNFL]), fundus autofluorescence measurement, infrared imaging, and full-field and multifocal electroretinogram. Optical coherence tomography and electrophysiological data were statistically compared with age- and sex-matched control groups.RESULTS: The basic clinical examination as well as the fundus autofluorescence and infrared images of the macular region were unremarkable. Neither the electrophysiological examinations nor optical coherence tomography yielded fundamental abnormalities. There were only two significant-albeit most likely clinically irrelevant-differences that occurred in comparison to the control group: a decrease in RNFL of the nasal quadrant in the OCT and a prolongation of the N1 implicit time of the second-ring eccentricity in the multifocal electroretinogram.CONCLUSIONS: The eyes and vision of heterozygous carriers of CLN3 disease showed normal features when compared to a control group, which controverts a previously suggested retinal dysfunction in these subjects.",
author = "Richard Bergholz and Alfried Kohlsch{\"u}tter and Angela Schulz and Waltraud Hubert and Klaus R{\"u}ther",
year = "2015",
month = aug,
doi = "10.1007/s00417-014-2814-0",
language = "English",
volume = "253",
pages = "1245--1250",
journal = "GRAEF ARCH CLIN EXP",
issn = "0721-832X",
publisher = "Springer",
number = "8",

}

RIS

TY - JOUR

T1 - Phenotyping heterozygous carriers of juvenile neuronal ceroid lipofuscinosis with CLN3 mutations

AU - Bergholz, Richard

AU - Kohlschütter, Alfried

AU - Schulz, Angela

AU - Hubert, Waltraud

AU - Rüther, Klaus

PY - 2015/8

Y1 - 2015/8

N2 - PURPOSE: The objective of this study was to establish an ophthalmologic phenotype of heterozygous carriers of juvenile neuronal ceroid lipofuscinosis (CLN3 disease, Batten disease).METHODS: The eyes and vision of nine heterozygous carriers of juvenile neuronal ceroid lipofuscinosis with classical CLN3 mutations were examined using the following methods: clinical examination, visual acuity, ophthalmoscopy, optical coherence tomography (macular thickness and peripapillary retinal nerve fibre layer measurement [RNFL]), fundus autofluorescence measurement, infrared imaging, and full-field and multifocal electroretinogram. Optical coherence tomography and electrophysiological data were statistically compared with age- and sex-matched control groups.RESULTS: The basic clinical examination as well as the fundus autofluorescence and infrared images of the macular region were unremarkable. Neither the electrophysiological examinations nor optical coherence tomography yielded fundamental abnormalities. There were only two significant-albeit most likely clinically irrelevant-differences that occurred in comparison to the control group: a decrease in RNFL of the nasal quadrant in the OCT and a prolongation of the N1 implicit time of the second-ring eccentricity in the multifocal electroretinogram.CONCLUSIONS: The eyes and vision of heterozygous carriers of CLN3 disease showed normal features when compared to a control group, which controverts a previously suggested retinal dysfunction in these subjects.

AB - PURPOSE: The objective of this study was to establish an ophthalmologic phenotype of heterozygous carriers of juvenile neuronal ceroid lipofuscinosis (CLN3 disease, Batten disease).METHODS: The eyes and vision of nine heterozygous carriers of juvenile neuronal ceroid lipofuscinosis with classical CLN3 mutations were examined using the following methods: clinical examination, visual acuity, ophthalmoscopy, optical coherence tomography (macular thickness and peripapillary retinal nerve fibre layer measurement [RNFL]), fundus autofluorescence measurement, infrared imaging, and full-field and multifocal electroretinogram. Optical coherence tomography and electrophysiological data were statistically compared with age- and sex-matched control groups.RESULTS: The basic clinical examination as well as the fundus autofluorescence and infrared images of the macular region were unremarkable. Neither the electrophysiological examinations nor optical coherence tomography yielded fundamental abnormalities. There were only two significant-albeit most likely clinically irrelevant-differences that occurred in comparison to the control group: a decrease in RNFL of the nasal quadrant in the OCT and a prolongation of the N1 implicit time of the second-ring eccentricity in the multifocal electroretinogram.CONCLUSIONS: The eyes and vision of heterozygous carriers of CLN3 disease showed normal features when compared to a control group, which controverts a previously suggested retinal dysfunction in these subjects.

U2 - 10.1007/s00417-014-2814-0

DO - 10.1007/s00417-014-2814-0

M3 - SCORING: Journal article

C2 - 25338278

VL - 253

SP - 1245

EP - 1250

JO - GRAEF ARCH CLIN EXP

JF - GRAEF ARCH CLIN EXP

SN - 0721-832X

IS - 8

ER -