Analysis of the influence of imaging-related uncertainties on cerebral aneurysm deformation quantification using a no-deformation physical flow phantom

Standard

Analysis of the influence of imaging-related uncertainties on cerebral aneurysm deformation quantification using a no-deformation physical flow phantom. / Schetelig, Daniel; Sedlacik, Jan; Fiehler, Jens; Frölich, Andreas; Knopp, Tobias; Sothmann, Thilo; Waschkewitz, Jonathan; Werner, René.

in: SCI REP-UK, Jahrgang 8, Nr. 1, 11004, 20.07.2018, S. 11004.

Publikationen: SCORING: Beitrag in Fachzeitschrift/ZeitungSCORING: ZeitschriftenaufsatzForschungBegutachtung

Harvard

APA

Vancouver

Bibtex

@article{d0515c1d5f474695a7a6fd9ad15c7dc2,
title = "Analysis of the influence of imaging-related uncertainties on cerebral aneurysm deformation quantification using a no-deformation physical flow phantom",
abstract = "Cardiac-cycle related pulsatile aneurysm motion and deformation is assumed to provide valuable information for assessing cerebral aneurysm rupture risk. Accordingly, numerous studies addressed quantification of cerebral aneurysm wall motion and deformation. Most of them utilized in vivo imaging data, but image-based aneurysm deformation quantification is subject to pronounced uncertainties: unknown ground-truth deformation; image resolution in the order of the expected deformation; direct interplay between contrast agent inflow and image intensity. To analyze the impact of the uncertainties on deformation quantification, a multi-imaging modality ground-truth phantom study is performed. A physical flow phantom was designed that allowed simulating pulsatile flow through a variety of modeled cerebral vascular structures. The phantom was imaged using different modalities [MRI, CT, 3D-RA] and mimicking physiologically realistic flow conditions. Resulting image data was analyzed by an established registration-based approach for automated wall motion quantification. The data reveals severe dependency between contrast media inflow-related image intensity changes and the extent of estimated wall deformation. The study illustrates that imaging-related uncertainties affect the accuracy of cerebral aneurysm deformation quantification, suggesting that in vivo imaging studies have to be accompanied by ground-truth phantom experiments to foster data interpretation and to prove plausibility of the applied image analysis algorithms.",
keywords = "Journal Article",
author = "Daniel Schetelig and Jan Sedlacik and Jens Fiehler and Andreas Fr{\"o}lich and Tobias Knopp and Thilo Sothmann and Jonathan Waschkewitz and Ren{\'e} Werner",
year = "2018",
month = jul,
day = "20",
doi = "10.1038/s41598-018-29282-0",
language = "English",
volume = "8",
pages = "11004",
journal = "SCI REP-UK",
issn = "2045-2322",
publisher = "NATURE PUBLISHING GROUP",
number = "1",

}

RIS

TY - JOUR

T1 - Analysis of the influence of imaging-related uncertainties on cerebral aneurysm deformation quantification using a no-deformation physical flow phantom

AU - Schetelig, Daniel

AU - Sedlacik, Jan

AU - Fiehler, Jens

AU - Frölich, Andreas

AU - Knopp, Tobias

AU - Sothmann, Thilo

AU - Waschkewitz, Jonathan

AU - Werner, René

PY - 2018/7/20

Y1 - 2018/7/20

N2 - Cardiac-cycle related pulsatile aneurysm motion and deformation is assumed to provide valuable information for assessing cerebral aneurysm rupture risk. Accordingly, numerous studies addressed quantification of cerebral aneurysm wall motion and deformation. Most of them utilized in vivo imaging data, but image-based aneurysm deformation quantification is subject to pronounced uncertainties: unknown ground-truth deformation; image resolution in the order of the expected deformation; direct interplay between contrast agent inflow and image intensity. To analyze the impact of the uncertainties on deformation quantification, a multi-imaging modality ground-truth phantom study is performed. A physical flow phantom was designed that allowed simulating pulsatile flow through a variety of modeled cerebral vascular structures. The phantom was imaged using different modalities [MRI, CT, 3D-RA] and mimicking physiologically realistic flow conditions. Resulting image data was analyzed by an established registration-based approach for automated wall motion quantification. The data reveals severe dependency between contrast media inflow-related image intensity changes and the extent of estimated wall deformation. The study illustrates that imaging-related uncertainties affect the accuracy of cerebral aneurysm deformation quantification, suggesting that in vivo imaging studies have to be accompanied by ground-truth phantom experiments to foster data interpretation and to prove plausibility of the applied image analysis algorithms.

AB - Cardiac-cycle related pulsatile aneurysm motion and deformation is assumed to provide valuable information for assessing cerebral aneurysm rupture risk. Accordingly, numerous studies addressed quantification of cerebral aneurysm wall motion and deformation. Most of them utilized in vivo imaging data, but image-based aneurysm deformation quantification is subject to pronounced uncertainties: unknown ground-truth deformation; image resolution in the order of the expected deformation; direct interplay between contrast agent inflow and image intensity. To analyze the impact of the uncertainties on deformation quantification, a multi-imaging modality ground-truth phantom study is performed. A physical flow phantom was designed that allowed simulating pulsatile flow through a variety of modeled cerebral vascular structures. The phantom was imaged using different modalities [MRI, CT, 3D-RA] and mimicking physiologically realistic flow conditions. Resulting image data was analyzed by an established registration-based approach for automated wall motion quantification. The data reveals severe dependency between contrast media inflow-related image intensity changes and the extent of estimated wall deformation. The study illustrates that imaging-related uncertainties affect the accuracy of cerebral aneurysm deformation quantification, suggesting that in vivo imaging studies have to be accompanied by ground-truth phantom experiments to foster data interpretation and to prove plausibility of the applied image analysis algorithms.

KW - Journal Article

U2 - 10.1038/s41598-018-29282-0

DO - 10.1038/s41598-018-29282-0

M3 - SCORING: Journal article

C2 - 30030483

VL - 8

SP - 11004

JO - SCI REP-UK

JF - SCI REP-UK

SN - 2045-2322

IS - 1

M1 - 11004

ER -