What is new in microcirculation and tissue oxygenation monitoring?

Standard

What is new in microcirculation and tissue oxygenation monitoring? / de Keijzer, Ilonka N; Massari, Dario; Sahinovic, Marko; Flick, Moritz; Vos, Jaap Jan; Scheeren, Thomas W L.

In: J CLIN MONIT COMPUT, Vol. 36, No. 2, 04.2022, p. 291-299.

Research output: SCORING: Contribution to journalSCORING: Review articleResearch

Harvard

de Keijzer, IN, Massari, D, Sahinovic, M, Flick, M, Vos, JJ & Scheeren, TWL 2022, 'What is new in microcirculation and tissue oxygenation monitoring?', J CLIN MONIT COMPUT, vol. 36, no. 2, pp. 291-299. https://doi.org/10.1007/s10877-022-00837-x

APA

de Keijzer, I. N., Massari, D., Sahinovic, M., Flick, M., Vos, J. J., & Scheeren, T. W. L. (2022). What is new in microcirculation and tissue oxygenation monitoring? J CLIN MONIT COMPUT, 36(2), 291-299. https://doi.org/10.1007/s10877-022-00837-x

Vancouver

Bibtex

@article{307878318d194f70b5558b6b225e6b16,
title = "What is new in microcirculation and tissue oxygenation monitoring?",
abstract = "Ensuring and maintaining adequate tissue oxygenation at the microcirculatory level might be considered the holy grail of optimal hemodynamic patient management. However, in clinical practice we usually focus on macro-hemodynamic variables such as blood pressure, heart rate, and sometimes cardiac output. Other macro-hemodynamic variables like pulse pressure or stroke volume variation are additionally used as markers of fluid responsiveness. In recent years, an increasing number of technological devices assessing tissue oxygenation or microcirculatory blood flow have been developed and validated, and some of them have already been incorporated into clinical practice. In this review, we will summarize recent research findings on this topic as published in the last 2 years in the Journal of Clinical Monitoring and Computing (JCMC). While some techniques are already currently used as routine monitoring (e.g. cerebral oxygenation using near-infrared spectroscopy (NIRS)), others still have to find their way into clinical practice. Therefore, further research is needed, particularly regarding outcome measures and cost-effectiveness, since introducing new technology is always expensive and should be balanced by downstream savings. The JCMC is glad to provide a platform for such research.",
author = "{de Keijzer}, {Ilonka N} and Dario Massari and Marko Sahinovic and Moritz Flick and Vos, {Jaap Jan} and Scheeren, {Thomas W L}",
note = "{\textcopyright} 2022. The Author(s).",
year = "2022",
month = apr,
doi = "10.1007/s10877-022-00837-x",
language = "English",
volume = "36",
pages = "291--299",
journal = "J CLIN MONIT COMPUT",
issn = "1387-1307",
publisher = "Springer Netherlands",
number = "2",

}

RIS

TY - JOUR

T1 - What is new in microcirculation and tissue oxygenation monitoring?

AU - de Keijzer, Ilonka N

AU - Massari, Dario

AU - Sahinovic, Marko

AU - Flick, Moritz

AU - Vos, Jaap Jan

AU - Scheeren, Thomas W L

N1 - © 2022. The Author(s).

PY - 2022/4

Y1 - 2022/4

N2 - Ensuring and maintaining adequate tissue oxygenation at the microcirculatory level might be considered the holy grail of optimal hemodynamic patient management. However, in clinical practice we usually focus on macro-hemodynamic variables such as blood pressure, heart rate, and sometimes cardiac output. Other macro-hemodynamic variables like pulse pressure or stroke volume variation are additionally used as markers of fluid responsiveness. In recent years, an increasing number of technological devices assessing tissue oxygenation or microcirculatory blood flow have been developed and validated, and some of them have already been incorporated into clinical practice. In this review, we will summarize recent research findings on this topic as published in the last 2 years in the Journal of Clinical Monitoring and Computing (JCMC). While some techniques are already currently used as routine monitoring (e.g. cerebral oxygenation using near-infrared spectroscopy (NIRS)), others still have to find their way into clinical practice. Therefore, further research is needed, particularly regarding outcome measures and cost-effectiveness, since introducing new technology is always expensive and should be balanced by downstream savings. The JCMC is glad to provide a platform for such research.

AB - Ensuring and maintaining adequate tissue oxygenation at the microcirculatory level might be considered the holy grail of optimal hemodynamic patient management. However, in clinical practice we usually focus on macro-hemodynamic variables such as blood pressure, heart rate, and sometimes cardiac output. Other macro-hemodynamic variables like pulse pressure or stroke volume variation are additionally used as markers of fluid responsiveness. In recent years, an increasing number of technological devices assessing tissue oxygenation or microcirculatory blood flow have been developed and validated, and some of them have already been incorporated into clinical practice. In this review, we will summarize recent research findings on this topic as published in the last 2 years in the Journal of Clinical Monitoring and Computing (JCMC). While some techniques are already currently used as routine monitoring (e.g. cerebral oxygenation using near-infrared spectroscopy (NIRS)), others still have to find their way into clinical practice. Therefore, further research is needed, particularly regarding outcome measures and cost-effectiveness, since introducing new technology is always expensive and should be balanced by downstream savings. The JCMC is glad to provide a platform for such research.

U2 - 10.1007/s10877-022-00837-x

DO - 10.1007/s10877-022-00837-x

M3 - SCORING: Review article

C2 - 35275312

VL - 36

SP - 291

EP - 299

JO - J CLIN MONIT COMPUT

JF - J CLIN MONIT COMPUT

SN - 1387-1307

IS - 2

ER -