Towards compartment size estimation in vivo based on double wave vector diffusion weighting.

Standard

Towards compartment size estimation in vivo based on double wave vector diffusion weighting. / Koch, Martin A.; Finsterbusch, Jürgen.

In: NMR BIOMED, Vol. 24, No. 10, 10, 2011, p. 1422-1432.

Research output: SCORING: Contribution to journalSCORING: Journal articleResearchpeer-review

Harvard

APA

Vancouver

Bibtex

@article{edaa17fb536a431abe47853f4f6f4785,
title = "Towards compartment size estimation in vivo based on double wave vector diffusion weighting.",
abstract = "It has been shown that double wave vector diffusion weighting, which employs two gradient pulse pairs of independent directions, can provide information about tissue structure that is not easily available otherwise, such as cell size or shape in a tissue sample. One approach to measure cell size is based on the signal difference between parallel and antiparallel gradient orientations at small mixing times between the two diffusion weightings. A major difficulty for in vivo application is the small size of the signal difference if clinical MR systems with limited gradient hardware are employed. In this study, the method is applied to human brain tissue in vivo, using whole-body gradients. Data are reported for the corticospinal tracts. The characteristics of the observed signal difference between parallel and antiparallel gradient orientations are consistent with both analytical and numerical predictions. As an estimate of pore size, the resulting mean squared radius of gyration of the pores amounts to approximately 4 µm(2) . An analysis that accounts for the finite values of gradient pulse duration and diffusion time yields a volume contribution-weighted mean pore diameter of 13 ?m if a cylindrical pore shape is assumed. The results demonstrate that the technique can be applied in vivo.",
keywords = "Humans, Electrocardiography, Organ Size, Diffusion Magnetic Resonance Imaging/*methods, Brain/*anatomy & histology, Echo-Planar Imaging, Humans, Electrocardiography, Organ Size, Diffusion Magnetic Resonance Imaging/*methods, Brain/*anatomy & histology, Echo-Planar Imaging",
author = "Koch, {Martin A.} and J{\"u}rgen Finsterbusch",
year = "2011",
language = "English",
volume = "24",
pages = "1422--1432",
journal = "NMR BIOMED",
issn = "0952-3480",
publisher = "John Wiley and Sons Ltd",
number = "10",

}

RIS

TY - JOUR

T1 - Towards compartment size estimation in vivo based on double wave vector diffusion weighting.

AU - Koch, Martin A.

AU - Finsterbusch, Jürgen

PY - 2011

Y1 - 2011

N2 - It has been shown that double wave vector diffusion weighting, which employs two gradient pulse pairs of independent directions, can provide information about tissue structure that is not easily available otherwise, such as cell size or shape in a tissue sample. One approach to measure cell size is based on the signal difference between parallel and antiparallel gradient orientations at small mixing times between the two diffusion weightings. A major difficulty for in vivo application is the small size of the signal difference if clinical MR systems with limited gradient hardware are employed. In this study, the method is applied to human brain tissue in vivo, using whole-body gradients. Data are reported for the corticospinal tracts. The characteristics of the observed signal difference between parallel and antiparallel gradient orientations are consistent with both analytical and numerical predictions. As an estimate of pore size, the resulting mean squared radius of gyration of the pores amounts to approximately 4 µm(2) . An analysis that accounts for the finite values of gradient pulse duration and diffusion time yields a volume contribution-weighted mean pore diameter of 13 ?m if a cylindrical pore shape is assumed. The results demonstrate that the technique can be applied in vivo.

AB - It has been shown that double wave vector diffusion weighting, which employs two gradient pulse pairs of independent directions, can provide information about tissue structure that is not easily available otherwise, such as cell size or shape in a tissue sample. One approach to measure cell size is based on the signal difference between parallel and antiparallel gradient orientations at small mixing times between the two diffusion weightings. A major difficulty for in vivo application is the small size of the signal difference if clinical MR systems with limited gradient hardware are employed. In this study, the method is applied to human brain tissue in vivo, using whole-body gradients. Data are reported for the corticospinal tracts. The characteristics of the observed signal difference between parallel and antiparallel gradient orientations are consistent with both analytical and numerical predictions. As an estimate of pore size, the resulting mean squared radius of gyration of the pores amounts to approximately 4 µm(2) . An analysis that accounts for the finite values of gradient pulse duration and diffusion time yields a volume contribution-weighted mean pore diameter of 13 ?m if a cylindrical pore shape is assumed. The results demonstrate that the technique can be applied in vivo.

KW - Humans

KW - Electrocardiography

KW - Organ Size

KW - Diffusion Magnetic Resonance Imaging/methods

KW - Brain/anatomy & histology

KW - Echo-Planar Imaging

KW - Humans

KW - Electrocardiography

KW - Organ Size

KW - Diffusion Magnetic Resonance Imaging/methods

KW - Brain/anatomy & histology

KW - Echo-Planar Imaging

M3 - SCORING: Journal article

VL - 24

SP - 1422

EP - 1432

JO - NMR BIOMED

JF - NMR BIOMED

SN - 0952-3480

IS - 10

M1 - 10