Thrombin generation test in children and adolescents with chronic liver disease

Standard

Thrombin generation test in children and adolescents with chronic liver disease. / Magnusson, Maria; Berndtsson, Maria; Fischler, Björn; Petrini, Pia; Schulman, Sam; Renne, Thomas; Granath, Anna; Sten-Linder, Margareta; Németh, Antal.

In: THROMB RES, Vol. 135, No. 2, 01.02.2015, p. 382-7.

Research output: SCORING: Contribution to journalSCORING: Journal articleResearchpeer-review

Harvard

Magnusson, M, Berndtsson, M, Fischler, B, Petrini, P, Schulman, S, Renne, T, Granath, A, Sten-Linder, M & Németh, A 2015, 'Thrombin generation test in children and adolescents with chronic liver disease', THROMB RES, vol. 135, no. 2, pp. 382-7. https://doi.org/10.1016/j.thromres.2014.11.040

APA

Magnusson, M., Berndtsson, M., Fischler, B., Petrini, P., Schulman, S., Renne, T., Granath, A., Sten-Linder, M., & Németh, A. (2015). Thrombin generation test in children and adolescents with chronic liver disease. THROMB RES, 135(2), 382-7. https://doi.org/10.1016/j.thromres.2014.11.040

Vancouver

Magnusson M, Berndtsson M, Fischler B, Petrini P, Schulman S, Renne T et al. Thrombin generation test in children and adolescents with chronic liver disease. THROMB RES. 2015 Feb 1;135(2):382-7. https://doi.org/10.1016/j.thromres.2014.11.040

Bibtex

@article{6930586ff0094918afc03e83c41ae0c0,
title = "Thrombin generation test in children and adolescents with chronic liver disease",
abstract = "INTRODUCTION: The aim of this study was to evaluate if real-time thrombin generation assay provides additional information to assess the hemostatic balance in children with liver disease as compared to routine coagulation tests.PATIENTS AND METHODS: Sixty-three children with chronic liver disease were enrolled at our tertiary referral center for pediatric hepatology, eight whose routine coagulation tests gave abnormal results (Group A) and 55 whose test results were normal (Group B). Abnormal routine coagulation test was defined as at least one of the following: international normalized ratio≥1.4, activated partial thromboplastin time>44 sec., fibrinogen<1.5 g/L. Platelet-poor plasma was analyzed with the fluorogenic Calibrated Automated Thrombogram to test for thrombin generation, including endogenous thrombin potential. Further, routine coagulation tests and plasma levels of pro- and anticoagulant factors were measured. Twenty age-matched children without liver disease served as controls.RESULTS: The endogenous thrombin potential in the 55 patients with normal routine coagulation tests was not significantly different from that in controls. Group A had significantly lower levels not only of procoagulant factors (II, V, VII, X) but simultaneously also of the anticoagulant factors antithrombin, protein S free, and protein C. These patients had a reduced endogenous thrombin potential compared to Group B, in agreement with their routine coagulation test results.CONCLUSION: Thrombin generation analysis seems to give information on the hemostatic balance consistent with routine coagulation test results in children with liver disease. Further development and clinical evaluation of the method are warranted.",
author = "Maria Magnusson and Maria Berndtsson and Bj{\"o}rn Fischler and Pia Petrini and Sam Schulman and Thomas Renne and Anna Granath and Margareta Sten-Linder and Antal N{\'e}meth",
note = "Copyright {\textcopyright} 2014 Elsevier Ltd. All rights reserved.",
year = "2015",
month = feb,
day = "1",
doi = "10.1016/j.thromres.2014.11.040",
language = "English",
volume = "135",
pages = "382--7",
journal = "THROMB RES",
issn = "0049-3848",
publisher = "Elsevier Limited",
number = "2",

}

RIS

TY - JOUR

T1 - Thrombin generation test in children and adolescents with chronic liver disease

AU - Magnusson, Maria

AU - Berndtsson, Maria

AU - Fischler, Björn

AU - Petrini, Pia

AU - Schulman, Sam

AU - Renne, Thomas

AU - Granath, Anna

AU - Sten-Linder, Margareta

AU - Németh, Antal

N1 - Copyright © 2014 Elsevier Ltd. All rights reserved.

PY - 2015/2/1

Y1 - 2015/2/1

N2 - INTRODUCTION: The aim of this study was to evaluate if real-time thrombin generation assay provides additional information to assess the hemostatic balance in children with liver disease as compared to routine coagulation tests.PATIENTS AND METHODS: Sixty-three children with chronic liver disease were enrolled at our tertiary referral center for pediatric hepatology, eight whose routine coagulation tests gave abnormal results (Group A) and 55 whose test results were normal (Group B). Abnormal routine coagulation test was defined as at least one of the following: international normalized ratio≥1.4, activated partial thromboplastin time>44 sec., fibrinogen<1.5 g/L. Platelet-poor plasma was analyzed with the fluorogenic Calibrated Automated Thrombogram to test for thrombin generation, including endogenous thrombin potential. Further, routine coagulation tests and plasma levels of pro- and anticoagulant factors were measured. Twenty age-matched children without liver disease served as controls.RESULTS: The endogenous thrombin potential in the 55 patients with normal routine coagulation tests was not significantly different from that in controls. Group A had significantly lower levels not only of procoagulant factors (II, V, VII, X) but simultaneously also of the anticoagulant factors antithrombin, protein S free, and protein C. These patients had a reduced endogenous thrombin potential compared to Group B, in agreement with their routine coagulation test results.CONCLUSION: Thrombin generation analysis seems to give information on the hemostatic balance consistent with routine coagulation test results in children with liver disease. Further development and clinical evaluation of the method are warranted.

AB - INTRODUCTION: The aim of this study was to evaluate if real-time thrombin generation assay provides additional information to assess the hemostatic balance in children with liver disease as compared to routine coagulation tests.PATIENTS AND METHODS: Sixty-three children with chronic liver disease were enrolled at our tertiary referral center for pediatric hepatology, eight whose routine coagulation tests gave abnormal results (Group A) and 55 whose test results were normal (Group B). Abnormal routine coagulation test was defined as at least one of the following: international normalized ratio≥1.4, activated partial thromboplastin time>44 sec., fibrinogen<1.5 g/L. Platelet-poor plasma was analyzed with the fluorogenic Calibrated Automated Thrombogram to test for thrombin generation, including endogenous thrombin potential. Further, routine coagulation tests and plasma levels of pro- and anticoagulant factors were measured. Twenty age-matched children without liver disease served as controls.RESULTS: The endogenous thrombin potential in the 55 patients with normal routine coagulation tests was not significantly different from that in controls. Group A had significantly lower levels not only of procoagulant factors (II, V, VII, X) but simultaneously also of the anticoagulant factors antithrombin, protein S free, and protein C. These patients had a reduced endogenous thrombin potential compared to Group B, in agreement with their routine coagulation test results.CONCLUSION: Thrombin generation analysis seems to give information on the hemostatic balance consistent with routine coagulation test results in children with liver disease. Further development and clinical evaluation of the method are warranted.

U2 - 10.1016/j.thromres.2014.11.040

DO - 10.1016/j.thromres.2014.11.040

M3 - SCORING: Journal article

C2 - 25541032

VL - 135

SP - 382

EP - 387

JO - THROMB RES

JF - THROMB RES

SN - 0049-3848

IS - 2

ER -