The Use of Intraoperative Cell Salvage in Two-Stage Revision of Septic Hip Arthroplasties: A Double-Center Retrospective Study

Standard

The Use of Intraoperative Cell Salvage in Two-Stage Revision of Septic Hip Arthroplasties: A Double-Center Retrospective Study. / Krüger, Lara; Strahl, André; Koepke, Leon-Gordian; Fink, Bernd; Beil, Frank Timo; Hubert, Jan.

In: ANTIBIOTICS-BASEL, Vol. 12, No. 6, 30.05.2023, p. 982.

Research output: SCORING: Contribution to journalSCORING: Journal articleResearchpeer-review

Harvard

APA

Vancouver

Bibtex

@article{48968aa5a18b459ca7d4ac44c675819c,
title = "The Use of Intraoperative Cell Salvage in Two-Stage Revision of Septic Hip Arthroplasties: A Double-Center Retrospective Study",
abstract = "(1) Background: intraoperative cell salvage (ICS) devices can provide a valuable contribution to patient blood management. An infection of the surgical site presents a formal contraindication to the use of ICS. To date, there is no recommendation for the use of ICS in the context of reimplantation in two-stage septic exchange arthroplasty. (2) Methods: at two hospitals of maximum endoprosthetic care, a retrospective evaluation of patients who had received ICS blood during reimplantation of hip arthroplasties was performed. Patients' and surgical characteristics, intraoperative cultures, and the occurrence of septic complications in the short- and long-term follow-up were recorded. (3) Results: 144 patients were included. Detection of positive cultures during reimplantation occurred in 13 cases. A total of 127 patients showed no complication, 8 patients showed a non-specific septic complication, 6 patients a local persistence of infection, and 3 patients a possible bloodstream-associated infection. No significant correlation was found between the occurrence of complications and the detection of positive intraoperative cultures. (4) Conclusions: no clustering of septic complications due to the use of ICS during reimplantation was found. In the risk-benefit analysis, we considered the use of ICS during reimplantation to be indicated in terms of patient blood management, while the safety of the procedure during septic first-stage resection arthroplasty or septic one-stage exchange arthroplasty was not investigated. Given the paucity of comparative literature, further studies are needed on ideal patient blood management in the setting of septic revision arthroplasty.",
author = "Lara Kr{\"u}ger and Andr{\'e} Strahl and Leon-Gordian Koepke and Bernd Fink and Beil, {Frank Timo} and Jan Hubert",
year = "2023",
month = may,
day = "30",
doi = "10.3390/antibiotics12060982",
language = "English",
volume = "12",
pages = "982",
journal = "ANTIBIOTICS-BASEL",
issn = "2079-6382",
publisher = "MDPI Multidisciplinary Digital Publishing Institute",
number = "6",

}

RIS

TY - JOUR

T1 - The Use of Intraoperative Cell Salvage in Two-Stage Revision of Septic Hip Arthroplasties: A Double-Center Retrospective Study

AU - Krüger, Lara

AU - Strahl, André

AU - Koepke, Leon-Gordian

AU - Fink, Bernd

AU - Beil, Frank Timo

AU - Hubert, Jan

PY - 2023/5/30

Y1 - 2023/5/30

N2 - (1) Background: intraoperative cell salvage (ICS) devices can provide a valuable contribution to patient blood management. An infection of the surgical site presents a formal contraindication to the use of ICS. To date, there is no recommendation for the use of ICS in the context of reimplantation in two-stage septic exchange arthroplasty. (2) Methods: at two hospitals of maximum endoprosthetic care, a retrospective evaluation of patients who had received ICS blood during reimplantation of hip arthroplasties was performed. Patients' and surgical characteristics, intraoperative cultures, and the occurrence of septic complications in the short- and long-term follow-up were recorded. (3) Results: 144 patients were included. Detection of positive cultures during reimplantation occurred in 13 cases. A total of 127 patients showed no complication, 8 patients showed a non-specific septic complication, 6 patients a local persistence of infection, and 3 patients a possible bloodstream-associated infection. No significant correlation was found between the occurrence of complications and the detection of positive intraoperative cultures. (4) Conclusions: no clustering of septic complications due to the use of ICS during reimplantation was found. In the risk-benefit analysis, we considered the use of ICS during reimplantation to be indicated in terms of patient blood management, while the safety of the procedure during septic first-stage resection arthroplasty or septic one-stage exchange arthroplasty was not investigated. Given the paucity of comparative literature, further studies are needed on ideal patient blood management in the setting of septic revision arthroplasty.

AB - (1) Background: intraoperative cell salvage (ICS) devices can provide a valuable contribution to patient blood management. An infection of the surgical site presents a formal contraindication to the use of ICS. To date, there is no recommendation for the use of ICS in the context of reimplantation in two-stage septic exchange arthroplasty. (2) Methods: at two hospitals of maximum endoprosthetic care, a retrospective evaluation of patients who had received ICS blood during reimplantation of hip arthroplasties was performed. Patients' and surgical characteristics, intraoperative cultures, and the occurrence of septic complications in the short- and long-term follow-up were recorded. (3) Results: 144 patients were included. Detection of positive cultures during reimplantation occurred in 13 cases. A total of 127 patients showed no complication, 8 patients showed a non-specific septic complication, 6 patients a local persistence of infection, and 3 patients a possible bloodstream-associated infection. No significant correlation was found between the occurrence of complications and the detection of positive intraoperative cultures. (4) Conclusions: no clustering of septic complications due to the use of ICS during reimplantation was found. In the risk-benefit analysis, we considered the use of ICS during reimplantation to be indicated in terms of patient blood management, while the safety of the procedure during septic first-stage resection arthroplasty or septic one-stage exchange arthroplasty was not investigated. Given the paucity of comparative literature, further studies are needed on ideal patient blood management in the setting of septic revision arthroplasty.

U2 - 10.3390/antibiotics12060982

DO - 10.3390/antibiotics12060982

M3 - SCORING: Journal article

C2 - 37370301

VL - 12

SP - 982

JO - ANTIBIOTICS-BASEL

JF - ANTIBIOTICS-BASEL

SN - 2079-6382

IS - 6

ER -