The SOURCE Registry: what is the learning curve in trans-apical aortic valve implantation?

Standard

The SOURCE Registry: what is the learning curve in trans-apical aortic valve implantation? / Wendler, Olaf; Walther, Thomas; Schroefel, Holger; Lange, Rüdiger; Treede, Hendrik; Fusari, Melissa; Rubino, Paolo; Thomas, Martyn.

In: EUR J CARDIO-THORAC, Vol. 39, No. 6, 06.2011, p. 853-859.

Research output: SCORING: Contribution to journalSCORING: Journal articleResearchpeer-review

Harvard

Wendler, O, Walther, T, Schroefel, H, Lange, R, Treede, H, Fusari, M, Rubino, P & Thomas, M 2011, 'The SOURCE Registry: what is the learning curve in trans-apical aortic valve implantation?', EUR J CARDIO-THORAC, vol. 39, no. 6, pp. 853-859. https://doi.org/10.1016/j.ejcts.2010.11.018

APA

Wendler, O., Walther, T., Schroefel, H., Lange, R., Treede, H., Fusari, M., Rubino, P., & Thomas, M. (2011). The SOURCE Registry: what is the learning curve in trans-apical aortic valve implantation? EUR J CARDIO-THORAC, 39(6), 853-859. https://doi.org/10.1016/j.ejcts.2010.11.018

Vancouver

Bibtex

@article{060c3ee9cf1f469895ba4285e12c6ee0,
title = "The SOURCE Registry: what is the learning curve in trans-apical aortic valve implantation?",
abstract = "OBJECTIVE: Trans-apical aortic valve implantation (TA-AVI) has been shown to be a reproducible technique. Early results from the SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) Registry identified major access complications associated with high 30-day mortality. Using the SOURCE Registry, we analyze the learning curve for TA-AVI over the first 2 years after commercialization.METHODS: The SOURCE Registry gathered data for 2 consecutive years at European centers following commercialization of the Edwards SAPIEN bioprosthesis, totaling 2339 patients (1038 in COHORT 1 and 1301 in COHORT 2). Only data from centers that provided all of their consecutively treated patients were included in this study. We compared the 30-day results of TA-AVI from COHORT 1 (C-1: January/2008-January/2009) with the 30-day results of COHORT 2 (C-2: February/2009-January/2010).RESULTS: This analysis is based on a total number of 575 TA-AVIs in C-1 and 819 TA-AVIs in C-2. Mean age (C-1: 80.7 years, C-2: 80.5 years) and logistic European System for Cardiac Operative Risk Evaluation (EuroSCORE) (C-1: 29.1%, C-2 27.3%) were not significantly different. Valve malposition (C-1: 1.6%, C-2: 1.2%), valve migration/embolization (C-1: 0.5%, C-2: 1.0%), and major access complications (C-1: 2.1%, C-2: 1.8%) were in total less frequent, but not statistically significant lower in C-2. However, the reduction of aortic regurgitation >2+ immediately following the procedure (C-1: 4.52%, C-2: 2.1%, p=0.011) and conversion rate to open surgery (C-1: 3.7%, C-2: 1.5%, p=0.0315) reached statistical significance. Postoperative complications included dialysis (C-1: 7.0%, C-2: 5.7%, p=ns), pacemaker implantation (C-2: 7.7%, C-2: 6.7%, p=ns), stroke (C-1: 2.4%, C-2: 2.6%, p=ns), and myocardial infarct (C-1: 0.7%, C-2: 0.4%, p=ns). The total 30-day mortality was 10.8% and not significantly different between the two groups (C-1: 10.8%, C-2: 10.7%, p=ns).CONCLUSIONS: Although the incidence of technical intra procedural complications has trended downward, reflecting the learning curve for TA-AVI, 30-day mortality was unchanged, likely due to patient co-morbidities not captured by preoperative risk variables.",
keywords = "Aged, Aged, 80 and over, Aortic Valve/surgery, Aortic Valve Stenosis/mortality, Bioprosthesis, Clinical Competence, Comorbidity, Education, Medical, Continuing, Europe/epidemiology, Female, Heart Valve Prosthesis, Heart Valve Prosthesis Implantation/adverse effects, Humans, Learning Curve, Male, Minimally Invasive Surgical Procedures/adverse effects, Registries, Treatment Outcome",
author = "Olaf Wendler and Thomas Walther and Holger Schroefel and R{\"u}diger Lange and Hendrik Treede and Melissa Fusari and Paolo Rubino and Martyn Thomas",
note = "Copyright {\textcopyright} 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.",
year = "2011",
month = jun,
doi = "10.1016/j.ejcts.2010.11.018",
language = "English",
volume = "39",
pages = "853--859",
journal = "EUR J CARDIO-THORAC",
issn = "1010-7940",
publisher = "Elsevier",
number = "6",

}

RIS

TY - JOUR

T1 - The SOURCE Registry: what is the learning curve in trans-apical aortic valve implantation?

AU - Wendler, Olaf

AU - Walther, Thomas

AU - Schroefel, Holger

AU - Lange, Rüdiger

AU - Treede, Hendrik

AU - Fusari, Melissa

AU - Rubino, Paolo

AU - Thomas, Martyn

N1 - Copyright © 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

PY - 2011/6

Y1 - 2011/6

N2 - OBJECTIVE: Trans-apical aortic valve implantation (TA-AVI) has been shown to be a reproducible technique. Early results from the SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) Registry identified major access complications associated with high 30-day mortality. Using the SOURCE Registry, we analyze the learning curve for TA-AVI over the first 2 years after commercialization.METHODS: The SOURCE Registry gathered data for 2 consecutive years at European centers following commercialization of the Edwards SAPIEN bioprosthesis, totaling 2339 patients (1038 in COHORT 1 and 1301 in COHORT 2). Only data from centers that provided all of their consecutively treated patients were included in this study. We compared the 30-day results of TA-AVI from COHORT 1 (C-1: January/2008-January/2009) with the 30-day results of COHORT 2 (C-2: February/2009-January/2010).RESULTS: This analysis is based on a total number of 575 TA-AVIs in C-1 and 819 TA-AVIs in C-2. Mean age (C-1: 80.7 years, C-2: 80.5 years) and logistic European System for Cardiac Operative Risk Evaluation (EuroSCORE) (C-1: 29.1%, C-2 27.3%) were not significantly different. Valve malposition (C-1: 1.6%, C-2: 1.2%), valve migration/embolization (C-1: 0.5%, C-2: 1.0%), and major access complications (C-1: 2.1%, C-2: 1.8%) were in total less frequent, but not statistically significant lower in C-2. However, the reduction of aortic regurgitation >2+ immediately following the procedure (C-1: 4.52%, C-2: 2.1%, p=0.011) and conversion rate to open surgery (C-1: 3.7%, C-2: 1.5%, p=0.0315) reached statistical significance. Postoperative complications included dialysis (C-1: 7.0%, C-2: 5.7%, p=ns), pacemaker implantation (C-2: 7.7%, C-2: 6.7%, p=ns), stroke (C-1: 2.4%, C-2: 2.6%, p=ns), and myocardial infarct (C-1: 0.7%, C-2: 0.4%, p=ns). The total 30-day mortality was 10.8% and not significantly different between the two groups (C-1: 10.8%, C-2: 10.7%, p=ns).CONCLUSIONS: Although the incidence of technical intra procedural complications has trended downward, reflecting the learning curve for TA-AVI, 30-day mortality was unchanged, likely due to patient co-morbidities not captured by preoperative risk variables.

AB - OBJECTIVE: Trans-apical aortic valve implantation (TA-AVI) has been shown to be a reproducible technique. Early results from the SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) Registry identified major access complications associated with high 30-day mortality. Using the SOURCE Registry, we analyze the learning curve for TA-AVI over the first 2 years after commercialization.METHODS: The SOURCE Registry gathered data for 2 consecutive years at European centers following commercialization of the Edwards SAPIEN bioprosthesis, totaling 2339 patients (1038 in COHORT 1 and 1301 in COHORT 2). Only data from centers that provided all of their consecutively treated patients were included in this study. We compared the 30-day results of TA-AVI from COHORT 1 (C-1: January/2008-January/2009) with the 30-day results of COHORT 2 (C-2: February/2009-January/2010).RESULTS: This analysis is based on a total number of 575 TA-AVIs in C-1 and 819 TA-AVIs in C-2. Mean age (C-1: 80.7 years, C-2: 80.5 years) and logistic European System for Cardiac Operative Risk Evaluation (EuroSCORE) (C-1: 29.1%, C-2 27.3%) were not significantly different. Valve malposition (C-1: 1.6%, C-2: 1.2%), valve migration/embolization (C-1: 0.5%, C-2: 1.0%), and major access complications (C-1: 2.1%, C-2: 1.8%) were in total less frequent, but not statistically significant lower in C-2. However, the reduction of aortic regurgitation >2+ immediately following the procedure (C-1: 4.52%, C-2: 2.1%, p=0.011) and conversion rate to open surgery (C-1: 3.7%, C-2: 1.5%, p=0.0315) reached statistical significance. Postoperative complications included dialysis (C-1: 7.0%, C-2: 5.7%, p=ns), pacemaker implantation (C-2: 7.7%, C-2: 6.7%, p=ns), stroke (C-1: 2.4%, C-2: 2.6%, p=ns), and myocardial infarct (C-1: 0.7%, C-2: 0.4%, p=ns). The total 30-day mortality was 10.8% and not significantly different between the two groups (C-1: 10.8%, C-2: 10.7%, p=ns).CONCLUSIONS: Although the incidence of technical intra procedural complications has trended downward, reflecting the learning curve for TA-AVI, 30-day mortality was unchanged, likely due to patient co-morbidities not captured by preoperative risk variables.

KW - Aged

KW - Aged, 80 and over

KW - Aortic Valve/surgery

KW - Aortic Valve Stenosis/mortality

KW - Bioprosthesis

KW - Clinical Competence

KW - Comorbidity

KW - Education, Medical, Continuing

KW - Europe/epidemiology

KW - Female

KW - Heart Valve Prosthesis

KW - Heart Valve Prosthesis Implantation/adverse effects

KW - Humans

KW - Learning Curve

KW - Male

KW - Minimally Invasive Surgical Procedures/adverse effects

KW - Registries

KW - Treatment Outcome

U2 - 10.1016/j.ejcts.2010.11.018

DO - 10.1016/j.ejcts.2010.11.018

M3 - SCORING: Journal article

C2 - 21183357

VL - 39

SP - 853

EP - 859

JO - EUR J CARDIO-THORAC

JF - EUR J CARDIO-THORAC

SN - 1010-7940

IS - 6

ER -