The effect of endotracheal tube cuff pressure control on postextubation throat pain in orthognathic surgeries: a randomized double-blind controlled clinical trial

Standard

The effect of endotracheal tube cuff pressure control on postextubation throat pain in orthognathic surgeries: a randomized double-blind controlled clinical trial. / Ansari, Ladan; Bohluli, Behnam; Mahaseni, Hamidreza; Valaei, Naser; Sadr-Eshkevari, Pooyan; Rashad, Ashkan.

In: BRIT J ORAL MAX SURG, Vol. 52, No. 2, 01.02.2014, p. 140-3.

Research output: SCORING: Contribution to journalSCORING: Journal articleResearchpeer-review

Harvard

APA

Vancouver

Bibtex

@article{ad571ac578de49ecb4b63c5d74f8298f,
title = "The effect of endotracheal tube cuff pressure control on postextubation throat pain in orthognathic surgeries: a randomized double-blind controlled clinical trial",
abstract = "Pain in the throat after extubation is one of the most common complaints after maxillofacial operations under general anaesthesia. We have evaluated the amount of pain after extubation when we controlled the pressure in the endotracheal cuff during operation by analysing the records of 43 patients who had maxillofacial operations under general anaesthesia. In the study group (n=20) the cuff pressure of the endotracheal tube was adjusted using a pressure gauge at the beginning of intubation and every hour during operation. In the control group (n=23), an experienced anaesthetist adjusted the pressure only at the beginning of the operation by palpating the pilot balloon. Throat pain was evaluated 1, 6, and 24h postoperatively on a visual analogue scale (VAS), and the pain scores in the control and study groups postoperatively was 5.3 (1.1) compared with 3.9 (1.5) (p=0.002); 4.5 (1.3) compared with 3.1 (1.5) (p=0.002); and 1.9 (1.1) compared with 1.6 (1.2) (p=0.4), respectively. The differences between the two groups at 1h and 6h postoperatively were significant, but that at 24h was not. Control of the cuff pressure of the endotracheal tube with a gauge at the beginning of the operation, and adjustment of the pressure during operation, can reduce postoperative complications such as throat pain.",
author = "Ladan Ansari and Behnam Bohluli and Hamidreza Mahaseni and Naser Valaei and Pooyan Sadr-Eshkevari and Ashkan Rashad",
note = "Copyright {\textcopyright} 2013 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.",
year = "2014",
month = feb,
day = "1",
doi = "10.1016/j.bjoms.2013.10.005",
language = "English",
volume = "52",
pages = "140--3",
journal = "BRIT J ORAL MAX SURG",
issn = "0266-4356",
publisher = "Churchill Livingstone",
number = "2",

}

RIS

TY - JOUR

T1 - The effect of endotracheal tube cuff pressure control on postextubation throat pain in orthognathic surgeries: a randomized double-blind controlled clinical trial

AU - Ansari, Ladan

AU - Bohluli, Behnam

AU - Mahaseni, Hamidreza

AU - Valaei, Naser

AU - Sadr-Eshkevari, Pooyan

AU - Rashad, Ashkan

N1 - Copyright © 2013 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

PY - 2014/2/1

Y1 - 2014/2/1

N2 - Pain in the throat after extubation is one of the most common complaints after maxillofacial operations under general anaesthesia. We have evaluated the amount of pain after extubation when we controlled the pressure in the endotracheal cuff during operation by analysing the records of 43 patients who had maxillofacial operations under general anaesthesia. In the study group (n=20) the cuff pressure of the endotracheal tube was adjusted using a pressure gauge at the beginning of intubation and every hour during operation. In the control group (n=23), an experienced anaesthetist adjusted the pressure only at the beginning of the operation by palpating the pilot balloon. Throat pain was evaluated 1, 6, and 24h postoperatively on a visual analogue scale (VAS), and the pain scores in the control and study groups postoperatively was 5.3 (1.1) compared with 3.9 (1.5) (p=0.002); 4.5 (1.3) compared with 3.1 (1.5) (p=0.002); and 1.9 (1.1) compared with 1.6 (1.2) (p=0.4), respectively. The differences between the two groups at 1h and 6h postoperatively were significant, but that at 24h was not. Control of the cuff pressure of the endotracheal tube with a gauge at the beginning of the operation, and adjustment of the pressure during operation, can reduce postoperative complications such as throat pain.

AB - Pain in the throat after extubation is one of the most common complaints after maxillofacial operations under general anaesthesia. We have evaluated the amount of pain after extubation when we controlled the pressure in the endotracheal cuff during operation by analysing the records of 43 patients who had maxillofacial operations under general anaesthesia. In the study group (n=20) the cuff pressure of the endotracheal tube was adjusted using a pressure gauge at the beginning of intubation and every hour during operation. In the control group (n=23), an experienced anaesthetist adjusted the pressure only at the beginning of the operation by palpating the pilot balloon. Throat pain was evaluated 1, 6, and 24h postoperatively on a visual analogue scale (VAS), and the pain scores in the control and study groups postoperatively was 5.3 (1.1) compared with 3.9 (1.5) (p=0.002); 4.5 (1.3) compared with 3.1 (1.5) (p=0.002); and 1.9 (1.1) compared with 1.6 (1.2) (p=0.4), respectively. The differences between the two groups at 1h and 6h postoperatively were significant, but that at 24h was not. Control of the cuff pressure of the endotracheal tube with a gauge at the beginning of the operation, and adjustment of the pressure during operation, can reduce postoperative complications such as throat pain.

U2 - 10.1016/j.bjoms.2013.10.005

DO - 10.1016/j.bjoms.2013.10.005

M3 - SCORING: Journal article

C2 - 24268872

VL - 52

SP - 140

EP - 143

JO - BRIT J ORAL MAX SURG

JF - BRIT J ORAL MAX SURG

SN - 0266-4356

IS - 2

ER -