Technical Aspects of Fenestrated Arch TEVAR With Preloaded Fenestration

Standard

Technical Aspects of Fenestrated Arch TEVAR With Preloaded Fenestration. / Prendes, Carlota F; Banafsche, Ramin; Stana, Jan; Binskin, Robert; Konstantinou, Nikolaos; Kölbel, Tilo; Tsilimparis, Nikolaos.

In: J ENDOVASC THER, Vol. 28, No. 4, 08.2021, p. 510-518.

Research output: SCORING: Contribution to journalSCORING: Journal articleResearchpeer-review

Harvard

Prendes, CF, Banafsche, R, Stana, J, Binskin, R, Konstantinou, N, Kölbel, T & Tsilimparis, N 2021, 'Technical Aspects of Fenestrated Arch TEVAR With Preloaded Fenestration', J ENDOVASC THER, vol. 28, no. 4, pp. 510-518. https://doi.org/10.1177/15266028211007469

APA

Prendes, C. F., Banafsche, R., Stana, J., Binskin, R., Konstantinou, N., Kölbel, T., & Tsilimparis, N. (2021). Technical Aspects of Fenestrated Arch TEVAR With Preloaded Fenestration. J ENDOVASC THER, 28(4), 510-518. https://doi.org/10.1177/15266028211007469

Vancouver

Prendes CF, Banafsche R, Stana J, Binskin R, Konstantinou N, Kölbel T et al. Technical Aspects of Fenestrated Arch TEVAR With Preloaded Fenestration. J ENDOVASC THER. 2021 Aug;28(4):510-518. https://doi.org/10.1177/15266028211007469

Bibtex

@article{0dbe940ebde2437ca576d8eebee083bb,
title = "Technical Aspects of Fenestrated Arch TEVAR With Preloaded Fenestration",
abstract = "Fenestrated thoracic endovascular aortic repair (f-TEVAR) has expanded the possibilities of endovascular arch repair, allowing treatment of pathologies involving the aortic arch that require sealing in Ishimaru zones 1 and 2. The growing number of implantations has increased physician experience and helped identify critical procedural points, mainly wire entanglement and device malrotation. Herein we describe a step-by-step approach to a f-TEVAR procedure with the Zenith fenestrated preloaded thoracic endograft, identifying potential pitfalls and suggesting problem-solving solutions.",
keywords = "Aneurysm, Dissecting/surgery, Aorta, Thoracic/diagnostic imaging, Aortic Aneurysm, Thoracic/diagnostic imaging, Blood Vessel Prosthesis, Blood Vessel Prosthesis Implantation/adverse effects, Endovascular Procedures/adverse effects, Humans, Prosthesis Design, Retrospective Studies, Stents, Treatment Outcome",
author = "Prendes, {Carlota F} and Ramin Banafsche and Jan Stana and Robert Binskin and Nikolaos Konstantinou and Tilo K{\"o}lbel and Nikolaos Tsilimparis",
year = "2021",
month = aug,
doi = "10.1177/15266028211007469",
language = "English",
volume = "28",
pages = "510--518",
journal = "J ENDOVASC THER",
issn = "1526-6028",
publisher = "International Society of Endovascular Specialists",
number = "4",

}

RIS

TY - JOUR

T1 - Technical Aspects of Fenestrated Arch TEVAR With Preloaded Fenestration

AU - Prendes, Carlota F

AU - Banafsche, Ramin

AU - Stana, Jan

AU - Binskin, Robert

AU - Konstantinou, Nikolaos

AU - Kölbel, Tilo

AU - Tsilimparis, Nikolaos

PY - 2021/8

Y1 - 2021/8

N2 - Fenestrated thoracic endovascular aortic repair (f-TEVAR) has expanded the possibilities of endovascular arch repair, allowing treatment of pathologies involving the aortic arch that require sealing in Ishimaru zones 1 and 2. The growing number of implantations has increased physician experience and helped identify critical procedural points, mainly wire entanglement and device malrotation. Herein we describe a step-by-step approach to a f-TEVAR procedure with the Zenith fenestrated preloaded thoracic endograft, identifying potential pitfalls and suggesting problem-solving solutions.

AB - Fenestrated thoracic endovascular aortic repair (f-TEVAR) has expanded the possibilities of endovascular arch repair, allowing treatment of pathologies involving the aortic arch that require sealing in Ishimaru zones 1 and 2. The growing number of implantations has increased physician experience and helped identify critical procedural points, mainly wire entanglement and device malrotation. Herein we describe a step-by-step approach to a f-TEVAR procedure with the Zenith fenestrated preloaded thoracic endograft, identifying potential pitfalls and suggesting problem-solving solutions.

KW - Aneurysm, Dissecting/surgery

KW - Aorta, Thoracic/diagnostic imaging

KW - Aortic Aneurysm, Thoracic/diagnostic imaging

KW - Blood Vessel Prosthesis

KW - Blood Vessel Prosthesis Implantation/adverse effects

KW - Endovascular Procedures/adverse effects

KW - Humans

KW - Prosthesis Design

KW - Retrospective Studies

KW - Stents

KW - Treatment Outcome

U2 - 10.1177/15266028211007469

DO - 10.1177/15266028211007469

M3 - SCORING: Journal article

C2 - 33834906

VL - 28

SP - 510

EP - 518

JO - J ENDOVASC THER

JF - J ENDOVASC THER

SN - 1526-6028

IS - 4

ER -