T2 and T2* measurements of fetal brain oxygenation during hypoxia with MRI at 3T: correlation with fetal arterial blood oxygen saturation.

Standard

T2 and T2* measurements of fetal brain oxygenation during hypoxia with MRI at 3T: correlation with fetal arterial blood oxygen saturation. / Wedegärtner, Ulrike; Kooijman, Hendrik; Andreas, Thomas; Beindorff, Nicola; Hecher, Kurt; Adam, Gerhard.

In: EUR RADIOL, Vol. 20, No. 1, 1, 2010, p. 121-127.

Research output: SCORING: Contribution to journalSCORING: Journal articleResearchpeer-review

Harvard

APA

Vancouver

Bibtex

@article{a9f79fcf08d54fe5bce84c9f31f85d93,
title = "T2 and T2* measurements of fetal brain oxygenation during hypoxia with MRI at 3T: correlation with fetal arterial blood oxygen saturation.",
abstract = "The purpose of this prospective study was to determine the oxygen saturation of blood in the fetal brain based on T2 and T2* measurements in a fetal sheep model. Five sheep fetuses were investigated during normoxia and hypoxia by 3T MRI. Multi-echo gradient-echo and turbo-spin-echo sequences were performed on the fetal brain. MR-determined oxygen saturation (MR-sO(2)) of blood in the fetal brain was calculated based on T2 and T2* values. Fetal arterial blood oxygen saturation (blood-sO(2)) was measured during the two experimental phases. The slope of MR-sO(2) as a function of blood-sO(2) was estimated and tested for compatibility using the one-sample t-test. During normoxia, mean values for carotid blood oxygen saturation were 67%, 83 ms for T2*, 202 ms for T2 and 96% for MR-sO(2). During hypoxia, arterial blood oxygen saturation, T2* and calculated MR-sO(2) decreased to 22%, 64 ms, and 68% respectively. The one-sample t-test revealed the slope to be significantly different from 0 (T = 5.023, df = 4, P = 0.007). It is feasible to perform quantitative T2 and T2* measurements in the fetal brain. MR-sO(2) and fetal arterial blood oxygen saturation correlated significantly. However, based on these data a reliable quantification of fetal brain tissue oxygenation is not possible.",
author = "Ulrike Wedeg{\"a}rtner and Hendrik Kooijman and Thomas Andreas and Nicola Beindorff and Kurt Hecher and Gerhard Adam",
year = "2010",
language = "Deutsch",
volume = "20",
pages = "121--127",
journal = "EUR RADIOL",
issn = "0938-7994",
publisher = "Springer",
number = "1",

}

RIS

TY - JOUR

T1 - T2 and T2* measurements of fetal brain oxygenation during hypoxia with MRI at 3T: correlation with fetal arterial blood oxygen saturation.

AU - Wedegärtner, Ulrike

AU - Kooijman, Hendrik

AU - Andreas, Thomas

AU - Beindorff, Nicola

AU - Hecher, Kurt

AU - Adam, Gerhard

PY - 2010

Y1 - 2010

N2 - The purpose of this prospective study was to determine the oxygen saturation of blood in the fetal brain based on T2 and T2* measurements in a fetal sheep model. Five sheep fetuses were investigated during normoxia and hypoxia by 3T MRI. Multi-echo gradient-echo and turbo-spin-echo sequences were performed on the fetal brain. MR-determined oxygen saturation (MR-sO(2)) of blood in the fetal brain was calculated based on T2 and T2* values. Fetal arterial blood oxygen saturation (blood-sO(2)) was measured during the two experimental phases. The slope of MR-sO(2) as a function of blood-sO(2) was estimated and tested for compatibility using the one-sample t-test. During normoxia, mean values for carotid blood oxygen saturation were 67%, 83 ms for T2*, 202 ms for T2 and 96% for MR-sO(2). During hypoxia, arterial blood oxygen saturation, T2* and calculated MR-sO(2) decreased to 22%, 64 ms, and 68% respectively. The one-sample t-test revealed the slope to be significantly different from 0 (T = 5.023, df = 4, P = 0.007). It is feasible to perform quantitative T2 and T2* measurements in the fetal brain. MR-sO(2) and fetal arterial blood oxygen saturation correlated significantly. However, based on these data a reliable quantification of fetal brain tissue oxygenation is not possible.

AB - The purpose of this prospective study was to determine the oxygen saturation of blood in the fetal brain based on T2 and T2* measurements in a fetal sheep model. Five sheep fetuses were investigated during normoxia and hypoxia by 3T MRI. Multi-echo gradient-echo and turbo-spin-echo sequences were performed on the fetal brain. MR-determined oxygen saturation (MR-sO(2)) of blood in the fetal brain was calculated based on T2 and T2* values. Fetal arterial blood oxygen saturation (blood-sO(2)) was measured during the two experimental phases. The slope of MR-sO(2) as a function of blood-sO(2) was estimated and tested for compatibility using the one-sample t-test. During normoxia, mean values for carotid blood oxygen saturation were 67%, 83 ms for T2*, 202 ms for T2 and 96% for MR-sO(2). During hypoxia, arterial blood oxygen saturation, T2* and calculated MR-sO(2) decreased to 22%, 64 ms, and 68% respectively. The one-sample t-test revealed the slope to be significantly different from 0 (T = 5.023, df = 4, P = 0.007). It is feasible to perform quantitative T2 and T2* measurements in the fetal brain. MR-sO(2) and fetal arterial blood oxygen saturation correlated significantly. However, based on these data a reliable quantification of fetal brain tissue oxygenation is not possible.

M3 - SCORING: Zeitschriftenaufsatz

VL - 20

SP - 121

EP - 127

JO - EUR RADIOL

JF - EUR RADIOL

SN - 0938-7994

IS - 1

M1 - 1

ER -