Strahlenexposition und dreidimensionale Darstellungsmöglichkeiten des SIREMOBIL Iso-C(3D) zur Planung chirurgischer Zahnsanierungen
Standard
Strahlenexposition und dreidimensionale Darstellungsmöglichkeiten des SIREMOBIL Iso-C(3D) zur Planung chirurgischer Zahnsanierungen. / Heiland, M; Schulze, D; Flinzberg, S; Thurmann, H; Rother, U; Schmelzle, R.
In: Mund Kiefer Gesichtschir, Vol. 8, No. 1, 01.02.2004, p. 35-40.Research output: SCORING: Contribution to journal › SCORING: Journal article › Research › peer-review
Harvard
APA
Vancouver
Bibtex
}
RIS
TY - JOUR
T1 - Strahlenexposition und dreidimensionale Darstellungsmöglichkeiten des SIREMOBIL Iso-C(3D) zur Planung chirurgischer Zahnsanierungen
AU - Heiland, M
AU - Schulze, D
AU - Flinzberg, S
AU - Thurmann, H
AU - Rother, U
AU - Schmelzle, R
PY - 2004/2/1
Y1 - 2004/2/1
N2 - BACKGROUND: Preoperative dental X-ray diagnostics of multimorbid, non compliant patients requiring dental surgery are often insufficient. The SIREMOBIL Iso-C(3D) has made intraoperative 3D imaging available, even for the facial skeleton. This modality was used intraoperatively in two patients referred for surgical dental treatment. Furthermore, radiation exposure of the SIREMOBIL Iso-C(3D), an orthopantomography and a complete dental status was compared.MATERIAL AND METHODS: An Alderson-Rando phantom was exposed to ten cycles of the SIREMOBIL Iso-C(3D) using the fast mode (50 projections). In comparison 28 panoramic views of an Orthophos and 10 sets of 14 dental images using the Oralix DC with a quadrate mask were applied. Twenty-five anatomically defined TLD positions were analyzed. Furthermore, SIREMOBIL Iso-C(3D) was used in one patient by performing 100 projections and in a second patient by performing 50 projections. After DICOM-import in eFilm, axial, coronal, and sagittal reconstructions were evaluated by five examiners regarding defined criteria.RESULTS: The radiation exposure level of the SIREMOBIL Iso-C(3D) was lower than in the complete dental status and only slightly higher in comparison with the orthopantomography, although the system requires the highest number of single projections. Quantitative evaluation of the visualization and recognition of defined structures proved to be very good and good in most points. However, limitations of the system became obvious regarding apical processes.CONCLUSION: Because of the dosimetry results and the visualization of the relevant structures, in patients for whom preoperative images cannot sufficiently be performed, the intraoperative use of the SIREMOBIL Iso-C(3D) as a base examination is justified.
AB - BACKGROUND: Preoperative dental X-ray diagnostics of multimorbid, non compliant patients requiring dental surgery are often insufficient. The SIREMOBIL Iso-C(3D) has made intraoperative 3D imaging available, even for the facial skeleton. This modality was used intraoperatively in two patients referred for surgical dental treatment. Furthermore, radiation exposure of the SIREMOBIL Iso-C(3D), an orthopantomography and a complete dental status was compared.MATERIAL AND METHODS: An Alderson-Rando phantom was exposed to ten cycles of the SIREMOBIL Iso-C(3D) using the fast mode (50 projections). In comparison 28 panoramic views of an Orthophos and 10 sets of 14 dental images using the Oralix DC with a quadrate mask were applied. Twenty-five anatomically defined TLD positions were analyzed. Furthermore, SIREMOBIL Iso-C(3D) was used in one patient by performing 100 projections and in a second patient by performing 50 projections. After DICOM-import in eFilm, axial, coronal, and sagittal reconstructions were evaluated by five examiners regarding defined criteria.RESULTS: The radiation exposure level of the SIREMOBIL Iso-C(3D) was lower than in the complete dental status and only slightly higher in comparison with the orthopantomography, although the system requires the highest number of single projections. Quantitative evaluation of the visualization and recognition of defined structures proved to be very good and good in most points. However, limitations of the system became obvious regarding apical processes.CONCLUSION: Because of the dosimetry results and the visualization of the relevant structures, in patients for whom preoperative images cannot sufficiently be performed, the intraoperative use of the SIREMOBIL Iso-C(3D) as a base examination is justified.
KW - Adult
KW - Equipment Safety
KW - Female
KW - Humans
KW - Image Processing, Computer-Assisted
KW - Imaging, Three-Dimensional
KW - Intensive Care Units
KW - Male
KW - Middle Aged
KW - Phantoms, Imaging
KW - Radiation Dosage
KW - Radiography, Panoramic
KW - Surgery, Computer-Assisted
KW - Surgery, Oral
KW - Thermoluminescent Dosimetry
KW - Tomography, X-Ray Computed
KW - Tooth Diseases
U2 - 10.1007/s10006-003-0521-9
DO - 10.1007/s10006-003-0521-9
M3 - SCORING: Zeitschriftenaufsatz
C2 - 14991419
VL - 8
SP - 35
EP - 40
IS - 1
ER -