Restenosis after stenting of matched occluded and non-occluded coronary arteries. Should there be a difference?

Standard

Restenosis after stenting of matched occluded and non-occluded coronary arteries. Should there be a difference? / Schofer, J; Rau, Thomas; Schlüter, M; Mathey, D G.

In: EUR HEART J, Vol. 20, No. 16, 16, 1999, p. 1175-1181.

Research output: SCORING: Contribution to journalSCORING: Journal articleResearchpeer-review

Harvard

APA

Vancouver

Bibtex

@article{1c83ebb3df2748e6b7d7ef1c03cc962b,
title = "Restenosis after stenting of matched occluded and non-occluded coronary arteries. Should there be a difference?",
abstract = "AIMS: It is not known whether the higher restenosis rates reported after balloon angioplasty of occluded as opposed to non-occluded coronary arteries are still found after placement of coronary stents in lesions matched for factors known to affect late angiographic outcome. METHODS AND RESULTS: In a retrospective analysis of 1276 patients who had undergone coronary stent placement and in whom 6-month angiographic follow-up was available, we identified 144 patients with a total coronary occlusion which matched a non-occluded coronary lesion in another 144 patients. Matching lesion pairs were of the same type (de novo or restenotic), were supplied with the same type of stent, had reference vessel diameters identical within 0.3 mm and stented vessel segment lengths identical within 8 mm, and were located in corresponding target vessels. After stenting, statistically identical minimal lumen diameters had been achieved in both groups (occluded: 2.74+/-0.35 mm, non-occluded: 2. 77+/-0.32 mm, P = 0.45). At follow-up, minimal lumen diameters were not different (occluded: 1.65+/-0.77 mm, non-occluded: 1.76+/-0.76 mm, P = 0.24), reflecting an identical late lumen loss for occlusions (1.09+/-0.76 mm) and non-occluded lesions (1.01+/-0.70 mm, P = 0.38). Because of the significantly larger acute gain, the loss index was significantly lower for occluded vessels (0.40+/-0.27 vs 0. 51+/-0.35, P = 0.003). Corresponding restenosis rates were 33% (occluded) and 28% (non-occluded;P = 0.44). For stented vessel segment lengths >18 mm, restenosis rates were markedly higher (occluded: 42%, non-occluded: 36%) than for stented vessel segment lengths",
author = "J Schofer and Thomas Rau and M Schl{\"u}ter and Mathey, {D G}",
year = "1999",
language = "Deutsch",
volume = "20",
pages = "1175--1181",
journal = "EUR HEART J",
issn = "0195-668X",
publisher = "Oxford University Press",
number = "16",

}

RIS

TY - JOUR

T1 - Restenosis after stenting of matched occluded and non-occluded coronary arteries. Should there be a difference?

AU - Schofer, J

AU - Rau, Thomas

AU - Schlüter, M

AU - Mathey, D G

PY - 1999

Y1 - 1999

N2 - AIMS: It is not known whether the higher restenosis rates reported after balloon angioplasty of occluded as opposed to non-occluded coronary arteries are still found after placement of coronary stents in lesions matched for factors known to affect late angiographic outcome. METHODS AND RESULTS: In a retrospective analysis of 1276 patients who had undergone coronary stent placement and in whom 6-month angiographic follow-up was available, we identified 144 patients with a total coronary occlusion which matched a non-occluded coronary lesion in another 144 patients. Matching lesion pairs were of the same type (de novo or restenotic), were supplied with the same type of stent, had reference vessel diameters identical within 0.3 mm and stented vessel segment lengths identical within 8 mm, and were located in corresponding target vessels. After stenting, statistically identical minimal lumen diameters had been achieved in both groups (occluded: 2.74+/-0.35 mm, non-occluded: 2. 77+/-0.32 mm, P = 0.45). At follow-up, minimal lumen diameters were not different (occluded: 1.65+/-0.77 mm, non-occluded: 1.76+/-0.76 mm, P = 0.24), reflecting an identical late lumen loss for occlusions (1.09+/-0.76 mm) and non-occluded lesions (1.01+/-0.70 mm, P = 0.38). Because of the significantly larger acute gain, the loss index was significantly lower for occluded vessels (0.40+/-0.27 vs 0. 51+/-0.35, P = 0.003). Corresponding restenosis rates were 33% (occluded) and 28% (non-occluded;P = 0.44). For stented vessel segment lengths >18 mm, restenosis rates were markedly higher (occluded: 42%, non-occluded: 36%) than for stented vessel segment lengths

AB - AIMS: It is not known whether the higher restenosis rates reported after balloon angioplasty of occluded as opposed to non-occluded coronary arteries are still found after placement of coronary stents in lesions matched for factors known to affect late angiographic outcome. METHODS AND RESULTS: In a retrospective analysis of 1276 patients who had undergone coronary stent placement and in whom 6-month angiographic follow-up was available, we identified 144 patients with a total coronary occlusion which matched a non-occluded coronary lesion in another 144 patients. Matching lesion pairs were of the same type (de novo or restenotic), were supplied with the same type of stent, had reference vessel diameters identical within 0.3 mm and stented vessel segment lengths identical within 8 mm, and were located in corresponding target vessels. After stenting, statistically identical minimal lumen diameters had been achieved in both groups (occluded: 2.74+/-0.35 mm, non-occluded: 2. 77+/-0.32 mm, P = 0.45). At follow-up, minimal lumen diameters were not different (occluded: 1.65+/-0.77 mm, non-occluded: 1.76+/-0.76 mm, P = 0.24), reflecting an identical late lumen loss for occlusions (1.09+/-0.76 mm) and non-occluded lesions (1.01+/-0.70 mm, P = 0.38). Because of the significantly larger acute gain, the loss index was significantly lower for occluded vessels (0.40+/-0.27 vs 0. 51+/-0.35, P = 0.003). Corresponding restenosis rates were 33% (occluded) and 28% (non-occluded;P = 0.44). For stented vessel segment lengths >18 mm, restenosis rates were markedly higher (occluded: 42%, non-occluded: 36%) than for stented vessel segment lengths

M3 - SCORING: Zeitschriftenaufsatz

VL - 20

SP - 1175

EP - 1181

JO - EUR HEART J

JF - EUR HEART J

SN - 0195-668X

IS - 16

M1 - 16

ER -