Repeated mobility testing for later artificial visual function evaluation.

Standard

Repeated mobility testing for later artificial visual function evaluation. / Velikay-Parel, M; Ivastinovic, D; Koch, M; Hornig, R; Dagnelie, G; Richard, Gisbert; Langmann, A.

In: J NEURAL ENG, Vol. 4, No. 1, 1, 2007, p. 102-107.

Research output: SCORING: Contribution to journalSCORING: Journal articleResearchpeer-review

Harvard

Velikay-Parel, M, Ivastinovic, D, Koch, M, Hornig, R, Dagnelie, G, Richard, G & Langmann, A 2007, 'Repeated mobility testing for later artificial visual function evaluation.', J NEURAL ENG, vol. 4, no. 1, 1, pp. 102-107. <http://www.ncbi.nlm.nih.gov/pubmed/17325408?dopt=Citation>

APA

Velikay-Parel, M., Ivastinovic, D., Koch, M., Hornig, R., Dagnelie, G., Richard, G., & Langmann, A. (2007). Repeated mobility testing for later artificial visual function evaluation. J NEURAL ENG, 4(1), 102-107. [1]. http://www.ncbi.nlm.nih.gov/pubmed/17325408?dopt=Citation

Vancouver

Velikay-Parel M, Ivastinovic D, Koch M, Hornig R, Dagnelie G, Richard G et al. Repeated mobility testing for later artificial visual function evaluation. J NEURAL ENG. 2007;4(1):102-107. 1.

Bibtex

@article{4d88861f10d249deb7d5967c52291a7f,
title = "Repeated mobility testing for later artificial visual function evaluation.",
abstract = "The study investigates the utility of a newly designed mobility test for repeated testing of visual function in patients with severe visual impairment and future application in evaluating functional progress in patients with artificial vision. Ten subjects divided into three groups based on visual acuity (VA) ranging from light perception to 20/200 and reduced visual field (VF) were included in the study. The mobility test consisted of using a set of four different but structurally similar and relatively short mazes having a constant number of obstacles of various sizes. The subjects, divided into three groups by acuity, passed through each course several times. In general, the patients with better VA had a larger extent of VF. Average speed and number of contacts were recorded as measures of performance. The average passing times of the groups through the courses were significantly different (p = 0.03), which was influenced by VA and VF. There was no significant difference in average number of contacts between the groups (p = 0.15). The mobility test proved to be appropriate for gaining statistically relevant results in repeated individual testing of patients with severe vision impairment. Results show promise for use this mobility test as a tool for assessing visual function of patients undergoing implantation of a visual prosthesis for artificial vision.",
author = "M Velikay-Parel and D Ivastinovic and M Koch and R Hornig and G Dagnelie and Gisbert Richard and A Langmann",
year = "2007",
language = "Deutsch",
volume = "4",
pages = "102--107",
journal = "J NEURAL ENG",
issn = "1741-2560",
publisher = "IOP Publishing Ltd.",
number = "1",

}

RIS

TY - JOUR

T1 - Repeated mobility testing for later artificial visual function evaluation.

AU - Velikay-Parel, M

AU - Ivastinovic, D

AU - Koch, M

AU - Hornig, R

AU - Dagnelie, G

AU - Richard, Gisbert

AU - Langmann, A

PY - 2007

Y1 - 2007

N2 - The study investigates the utility of a newly designed mobility test for repeated testing of visual function in patients with severe visual impairment and future application in evaluating functional progress in patients with artificial vision. Ten subjects divided into three groups based on visual acuity (VA) ranging from light perception to 20/200 and reduced visual field (VF) were included in the study. The mobility test consisted of using a set of four different but structurally similar and relatively short mazes having a constant number of obstacles of various sizes. The subjects, divided into three groups by acuity, passed through each course several times. In general, the patients with better VA had a larger extent of VF. Average speed and number of contacts were recorded as measures of performance. The average passing times of the groups through the courses were significantly different (p = 0.03), which was influenced by VA and VF. There was no significant difference in average number of contacts between the groups (p = 0.15). The mobility test proved to be appropriate for gaining statistically relevant results in repeated individual testing of patients with severe vision impairment. Results show promise for use this mobility test as a tool for assessing visual function of patients undergoing implantation of a visual prosthesis for artificial vision.

AB - The study investigates the utility of a newly designed mobility test for repeated testing of visual function in patients with severe visual impairment and future application in evaluating functional progress in patients with artificial vision. Ten subjects divided into three groups based on visual acuity (VA) ranging from light perception to 20/200 and reduced visual field (VF) were included in the study. The mobility test consisted of using a set of four different but structurally similar and relatively short mazes having a constant number of obstacles of various sizes. The subjects, divided into three groups by acuity, passed through each course several times. In general, the patients with better VA had a larger extent of VF. Average speed and number of contacts were recorded as measures of performance. The average passing times of the groups through the courses were significantly different (p = 0.03), which was influenced by VA and VF. There was no significant difference in average number of contacts between the groups (p = 0.15). The mobility test proved to be appropriate for gaining statistically relevant results in repeated individual testing of patients with severe vision impairment. Results show promise for use this mobility test as a tool for assessing visual function of patients undergoing implantation of a visual prosthesis for artificial vision.

M3 - SCORING: Zeitschriftenaufsatz

VL - 4

SP - 102

EP - 107

JO - J NEURAL ENG

JF - J NEURAL ENG

SN - 1741-2560

IS - 1

M1 - 1

ER -