Reliable and Easy-To-Use Liquid Chromatography-Tandem Mass Spectrometry Assay for Quantification of Olorofim (F901318), a Novel Antifungal Drug, in Human Plasma and Serum

Standard

Reliable and Easy-To-Use Liquid Chromatography-Tandem Mass Spectrometry Assay for Quantification of Olorofim (F901318), a Novel Antifungal Drug, in Human Plasma and Serum. / Müller, Carsten; Fietz, Cornelia; Koehler, Philipp; Sibley, Graham; Nforbugwe, Achu Che Awah; Streichert, Thomas; Wiesen, Martin H J.

In: ANTIMICROB AGENTS CH, Vol. 62, No. 11, 11.2018.

Research output: SCORING: Contribution to journalSCORING: Journal articleResearchpeer-review

Harvard

APA

Vancouver

Bibtex

@article{331064d66b7746f09ee2a17f71c8b017,
title = "Reliable and Easy-To-Use Liquid Chromatography-Tandem Mass Spectrometry Assay for Quantification of Olorofim (F901318), a Novel Antifungal Drug, in Human Plasma and Serum",
abstract = "A fast and easy-to-use liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination and quantification of a novel antifungal drug, olorofim (F901318), a member of the novel class of orotomides, in human plasma and serum was developed and validated. Sample preparation was based on protein precipitation with acetonitrile and subsequent centrifugation. An isotope-labeled analogue of F901318 was employed as an internal standard. Chromatographic separation was achieved using a 50-mm by 2.1-mm, 1.9-μm, polar Hypersil Gold C18 column and isocratic mobile phase consisting of 0.1% formic acid-acetonitrile (60%-40%, vol/vol) at a flow rate of 330 μl/min. The analyte was detected using a triple-stage quadrupole mass spectrometer operated in selected reaction monitoring (SRM) mode with positive heated electrospray ionization (HESI+) within a single runtime of 2.00 min. The present LC-MS/MS method was validated according to the international guidelines of the International Conference on Harmonisation (ICH) and the U.S. Food and Drug Administration (FDA). Linearity of F901318 concentration ranges was verified by the Mandel test. The calibration curve was tested linear across the range and fitted using least-squares regression with a weighting factor of the reciprocal concentration. The limit of detection was 0.0011 mg/liter, and the lower limit of quantitation was 0.0033 mg/liter. Intraday and interday precisions ranged from 1.17% to 3.23% for F901318, and intraday and interday accuracies (percent bias) ranged from 0.75% to 5.01%. In conclusion, a method was established for the rapid quantitation of F901318 concentrations in serum and plasma samples in patient trials, and it optimizes therapeutic drug monitoring in applying an easy-to-use single method.",
keywords = "Journal Article",
author = "Carsten M{\"u}ller and Cornelia Fietz and Philipp Koehler and Graham Sibley and Nforbugwe, {Achu Che Awah} and Thomas Streichert and Wiesen, {Martin H J}",
note = "Copyright {\textcopyright} 2018 American Society for Microbiology.",
year = "2018",
month = nov,
doi = "10.1128/AAC.01356-18",
language = "English",
volume = "62",
journal = "ANTIMICROB AGENTS CH",
issn = "0066-4804",
publisher = "American Society for Microbiology",
number = "11",

}

RIS

TY - JOUR

T1 - Reliable and Easy-To-Use Liquid Chromatography-Tandem Mass Spectrometry Assay for Quantification of Olorofim (F901318), a Novel Antifungal Drug, in Human Plasma and Serum

AU - Müller, Carsten

AU - Fietz, Cornelia

AU - Koehler, Philipp

AU - Sibley, Graham

AU - Nforbugwe, Achu Che Awah

AU - Streichert, Thomas

AU - Wiesen, Martin H J

N1 - Copyright © 2018 American Society for Microbiology.

PY - 2018/11

Y1 - 2018/11

N2 - A fast and easy-to-use liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination and quantification of a novel antifungal drug, olorofim (F901318), a member of the novel class of orotomides, in human plasma and serum was developed and validated. Sample preparation was based on protein precipitation with acetonitrile and subsequent centrifugation. An isotope-labeled analogue of F901318 was employed as an internal standard. Chromatographic separation was achieved using a 50-mm by 2.1-mm, 1.9-μm, polar Hypersil Gold C18 column and isocratic mobile phase consisting of 0.1% formic acid-acetonitrile (60%-40%, vol/vol) at a flow rate of 330 μl/min. The analyte was detected using a triple-stage quadrupole mass spectrometer operated in selected reaction monitoring (SRM) mode with positive heated electrospray ionization (HESI+) within a single runtime of 2.00 min. The present LC-MS/MS method was validated according to the international guidelines of the International Conference on Harmonisation (ICH) and the U.S. Food and Drug Administration (FDA). Linearity of F901318 concentration ranges was verified by the Mandel test. The calibration curve was tested linear across the range and fitted using least-squares regression with a weighting factor of the reciprocal concentration. The limit of detection was 0.0011 mg/liter, and the lower limit of quantitation was 0.0033 mg/liter. Intraday and interday precisions ranged from 1.17% to 3.23% for F901318, and intraday and interday accuracies (percent bias) ranged from 0.75% to 5.01%. In conclusion, a method was established for the rapid quantitation of F901318 concentrations in serum and plasma samples in patient trials, and it optimizes therapeutic drug monitoring in applying an easy-to-use single method.

AB - A fast and easy-to-use liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination and quantification of a novel antifungal drug, olorofim (F901318), a member of the novel class of orotomides, in human plasma and serum was developed and validated. Sample preparation was based on protein precipitation with acetonitrile and subsequent centrifugation. An isotope-labeled analogue of F901318 was employed as an internal standard. Chromatographic separation was achieved using a 50-mm by 2.1-mm, 1.9-μm, polar Hypersil Gold C18 column and isocratic mobile phase consisting of 0.1% formic acid-acetonitrile (60%-40%, vol/vol) at a flow rate of 330 μl/min. The analyte was detected using a triple-stage quadrupole mass spectrometer operated in selected reaction monitoring (SRM) mode with positive heated electrospray ionization (HESI+) within a single runtime of 2.00 min. The present LC-MS/MS method was validated according to the international guidelines of the International Conference on Harmonisation (ICH) and the U.S. Food and Drug Administration (FDA). Linearity of F901318 concentration ranges was verified by the Mandel test. The calibration curve was tested linear across the range and fitted using least-squares regression with a weighting factor of the reciprocal concentration. The limit of detection was 0.0011 mg/liter, and the lower limit of quantitation was 0.0033 mg/liter. Intraday and interday precisions ranged from 1.17% to 3.23% for F901318, and intraday and interday accuracies (percent bias) ranged from 0.75% to 5.01%. In conclusion, a method was established for the rapid quantitation of F901318 concentrations in serum and plasma samples in patient trials, and it optimizes therapeutic drug monitoring in applying an easy-to-use single method.

KW - Journal Article

U2 - 10.1128/AAC.01356-18

DO - 10.1128/AAC.01356-18

M3 - SCORING: Journal article

C2 - 30150474

VL - 62

JO - ANTIMICROB AGENTS CH

JF - ANTIMICROB AGENTS CH

SN - 0066-4804

IS - 11

ER -