Rapid pacing for better placing: comparison of techniques for precise deployment of endografts in the thoracic aorta.

  • Christoph A Nienaber
  • Stephan Kische
  • Tim C Rehders
  • Henrik Schneider
  • Tushar Chatterjee
  • Carsten Michael Bünger
  • Regina Thuneke
  • Hüseyin Ince

Related Research units

Abstract

PURPOSE: To investigate the safety, efficacy, impact on positioning, and neurocognitive outcomes of 3 conceptually different methods of avoiding the "windsock" effect during thoracic stent-graft placement. METHODS: A retrospective review was conducted of 70 patients (48 men; mean age 63 years) who underwent elective or emergency stent-graft placement in the thoracic aorta for various pathologies. Twenty-seven patients (18 men; mean age 64+/-12 years) had stent-graft positioning during rapid right ventricular (RV) pacing at 180 to 200 beats per minute. Another 27 patients (18 men; mean age 62+/-12 years) had stent-graft placement under controlled hypotension (

Bibliographical data

Original languageGerman
Article number4
ISSN1526-6028
Publication statusPublished - 2007
pubmed 17696625