Rapid detection of methicillin resistance in coagulase-negative Staphylococci with the VITEK 2 system.
Standard
Rapid detection of methicillin resistance in coagulase-negative Staphylococci with the VITEK 2 system. / Horstkotte, Matthias A; Knobloch, Johannes K-M; Rohde, Holger; Dobinsky, Sabine; Mack, Dietrich.
In: J CLIN MICROBIOL, Vol. 40, No. 9, 9, 2002, p. 3291-3295.Research output: SCORING: Contribution to journal › SCORING: Journal article › Research › peer-review
Harvard
APA
Vancouver
Bibtex
}
RIS
TY - JOUR
T1 - Rapid detection of methicillin resistance in coagulase-negative Staphylococci with the VITEK 2 system.
AU - Horstkotte, Matthias A
AU - Knobloch, Johannes K-M
AU - Rohde, Holger
AU - Dobinsky, Sabine
AU - Mack, Dietrich
PY - 2002
Y1 - 2002
N2 - The aim of the present study was to evaluate the accuracy of the new VITEK 2 system (bioMérieux, Marcy l' Etoile, France) for the detection of methicillin resistance in coagulase-negative staphylococci (CoNS) by using AST-P515 and AST-P523 test cards. Analyses of the VITEK 2 oxacillin MIC determination evaluated according to the actual breakpoint (>/=0.5 micro g/ml) of the National Committee for Clinical Laboratory Standards resulted in a high sensitivity of 99.2% but a moderate specificity of 80%. The newly included oxacillin resistance (OR) test of the VITEK 2 system displayed a high sensitivity and a high specificity of 97.5 and 98.7%, respectively. Concordance between the results of the mecA PCR and the VITEK 2 oxacillin MIC was observed for almost all Staphylococcus epidermidis strains, but the reduced specificity was attributable to higher oxacillin MICs for mecA-negative non-S. epidermidis strains, especially S. saprophyticus, S. lugdunensis, and S. cohnii. Evaluation of alternative oxacillin MIC breakpoints of 1, 2, or 4 micro g/ml resulted in improved degrees of specificity of 84, 90.7, and 97.3%, respectively. Only minor changes occurred in the corresponding sensitivity values, which were 98.4, 97.5, and 97.5%, respectively. Methicillin resistance in CoNS was detected after 7 and 8 h in 91.1 and 93.5% of the mecA-positive strains, respectively, by the VITEK 2 OR test and in 86.3 and 89.5% of the mecA-positive strains, respectively, by VITEK 2 oxacillin MIC determination. After 7 and 8 h the VITEK 2 OR test classified 59.2 and 78.9% of the mecA-negative strains, respectively, as susceptible to oxacillin, whereas comparable values were obtained 2 h later by VITEK 2 oxacillin MIC determination. The results of our study encourage the use of the VITEK 2 system, which proved to be a highly reliable and rapid phenotypic method for the detection of methicillin resistance in CoNS.
AB - The aim of the present study was to evaluate the accuracy of the new VITEK 2 system (bioMérieux, Marcy l' Etoile, France) for the detection of methicillin resistance in coagulase-negative staphylococci (CoNS) by using AST-P515 and AST-P523 test cards. Analyses of the VITEK 2 oxacillin MIC determination evaluated according to the actual breakpoint (>/=0.5 micro g/ml) of the National Committee for Clinical Laboratory Standards resulted in a high sensitivity of 99.2% but a moderate specificity of 80%. The newly included oxacillin resistance (OR) test of the VITEK 2 system displayed a high sensitivity and a high specificity of 97.5 and 98.7%, respectively. Concordance between the results of the mecA PCR and the VITEK 2 oxacillin MIC was observed for almost all Staphylococcus epidermidis strains, but the reduced specificity was attributable to higher oxacillin MICs for mecA-negative non-S. epidermidis strains, especially S. saprophyticus, S. lugdunensis, and S. cohnii. Evaluation of alternative oxacillin MIC breakpoints of 1, 2, or 4 micro g/ml resulted in improved degrees of specificity of 84, 90.7, and 97.3%, respectively. Only minor changes occurred in the corresponding sensitivity values, which were 98.4, 97.5, and 97.5%, respectively. Methicillin resistance in CoNS was detected after 7 and 8 h in 91.1 and 93.5% of the mecA-positive strains, respectively, by the VITEK 2 OR test and in 86.3 and 89.5% of the mecA-positive strains, respectively, by VITEK 2 oxacillin MIC determination. After 7 and 8 h the VITEK 2 OR test classified 59.2 and 78.9% of the mecA-negative strains, respectively, as susceptible to oxacillin, whereas comparable values were obtained 2 h later by VITEK 2 oxacillin MIC determination. The results of our study encourage the use of the VITEK 2 system, which proved to be a highly reliable and rapid phenotypic method for the detection of methicillin resistance in CoNS.
U2 - 10.1128/JCM.40.9.3291-3295.2002
DO - 10.1128/JCM.40.9.3291-3295.2002
M3 - SCORING: Zeitschriftenaufsatz
VL - 40
SP - 3291
EP - 3295
JO - J CLIN MICROBIOL
JF - J CLIN MICROBIOL
SN - 0095-1137
IS - 9
M1 - 9
ER -