Radiation exposure by digital radiographic imaging in very low birth weight infants
Related Research units
Abstract
OBJECTIVE: The aim of this study was to determine the cumulative effective doses (CED) from digital radiographic imaging in very low birth weight infants treated in a tertiary care neonatal intensive care unit (NICU).
STUDY DESIGN: The CED for each infant was retrospectively calculated using a voxel-based model. The results were compared with previous studies applying conventional radiography.
RESULTS: Two hundred and six preterm infants were included into this study. Neonates received a median of four radiographs (range: 1-68) and a CED of 50 µSv (4-883 µSv). Overall mean CED was lower than in previously published data applying conventional radiography. Factors contributing to a lower radiation dose per infant in our study were a lower number of radiographs and smaller field sizes per radiographic image.
CONCLUSIONS: The number of conducted radiographs per patient and the employed field size had a higher impact on the CED than the applied radiographic technology.
Bibliographical data
Original language | English |
---|---|
ISSN | 0743-8346 |
DOIs | |
Publication status | Published - 01.2019 |
PubMed | 30459389 |
---|