Preparing Laboratories for Interconnected Health Care

Standard

Preparing Laboratories for Interconnected Health Care. / Bietenbeck, Andreas; Streichert, Thomas.

In: DIAGNOSTICS, Vol. 11, No. 8, 17.08.2021, p. 1487.

Research output: SCORING: Contribution to journalSCORING: Review articleResearch

Harvard

APA

Vancouver

Bibtex

@article{55643b3b0dca4a879a1a711bd58b08f6,
title = "Preparing Laboratories for Interconnected Health Care",
abstract = "In an increasingly interconnected health care system, laboratory medicine can facilitate diagnosis and treatment of patients effectively. This article describes necessary changes and points to potential challenges on a technical, content, and organizational level. As a technical precondition, electronic laboratory reports have to become machine-readable and interpretable. Terminologies such as Logical Observation Identifiers Names and Codes (LOINC), Nomenclature for Properties and Units (NPU), Unified Code for Units of Measure (UCUM), and SNOMED-CT can lead to the necessary semantic interoperability. Even if only single {"}atomized{"} results of the whole report are extracted, the necessary information for correct interpretation must be available. Therefore, interpretive comments, e.g., concerns about an increased measurement uncertainty must be electronically attached to every affected measurement result. Standardization of laboratory analyses with traceable standards and reference materials will enable knowledge transfer and safe interpretation of laboratory analyses from multiple laboratories. In an interconnected health care system, laboratories should strive to transform themselves into a data hub that not only receives samples but also extensive information about the patient. On that basis, they can return measurement results enriched with high-quality interpretive comments tailored to the individual patient and unlock the full potential of laboratory medicine.",
author = "Andreas Bietenbeck and Thomas Streichert",
year = "2021",
month = aug,
day = "17",
doi = "10.3390/diagnostics11081487",
language = "English",
volume = "11",
pages = "1487",
journal = "DIAGNOSTICS",
issn = "2075-4418",
publisher = "MDPI AG",
number = "8",

}

RIS

TY - JOUR

T1 - Preparing Laboratories for Interconnected Health Care

AU - Bietenbeck, Andreas

AU - Streichert, Thomas

PY - 2021/8/17

Y1 - 2021/8/17

N2 - In an increasingly interconnected health care system, laboratory medicine can facilitate diagnosis and treatment of patients effectively. This article describes necessary changes and points to potential challenges on a technical, content, and organizational level. As a technical precondition, electronic laboratory reports have to become machine-readable and interpretable. Terminologies such as Logical Observation Identifiers Names and Codes (LOINC), Nomenclature for Properties and Units (NPU), Unified Code for Units of Measure (UCUM), and SNOMED-CT can lead to the necessary semantic interoperability. Even if only single "atomized" results of the whole report are extracted, the necessary information for correct interpretation must be available. Therefore, interpretive comments, e.g., concerns about an increased measurement uncertainty must be electronically attached to every affected measurement result. Standardization of laboratory analyses with traceable standards and reference materials will enable knowledge transfer and safe interpretation of laboratory analyses from multiple laboratories. In an interconnected health care system, laboratories should strive to transform themselves into a data hub that not only receives samples but also extensive information about the patient. On that basis, they can return measurement results enriched with high-quality interpretive comments tailored to the individual patient and unlock the full potential of laboratory medicine.

AB - In an increasingly interconnected health care system, laboratory medicine can facilitate diagnosis and treatment of patients effectively. This article describes necessary changes and points to potential challenges on a technical, content, and organizational level. As a technical precondition, electronic laboratory reports have to become machine-readable and interpretable. Terminologies such as Logical Observation Identifiers Names and Codes (LOINC), Nomenclature for Properties and Units (NPU), Unified Code for Units of Measure (UCUM), and SNOMED-CT can lead to the necessary semantic interoperability. Even if only single "atomized" results of the whole report are extracted, the necessary information for correct interpretation must be available. Therefore, interpretive comments, e.g., concerns about an increased measurement uncertainty must be electronically attached to every affected measurement result. Standardization of laboratory analyses with traceable standards and reference materials will enable knowledge transfer and safe interpretation of laboratory analyses from multiple laboratories. In an interconnected health care system, laboratories should strive to transform themselves into a data hub that not only receives samples but also extensive information about the patient. On that basis, they can return measurement results enriched with high-quality interpretive comments tailored to the individual patient and unlock the full potential of laboratory medicine.

U2 - 10.3390/diagnostics11081487

DO - 10.3390/diagnostics11081487

M3 - SCORING: Review article

C2 - 34441421

VL - 11

SP - 1487

JO - DIAGNOSTICS

JF - DIAGNOSTICS

SN - 2075-4418

IS - 8

ER -