[Preoperative assessment of intraocular lens corrected vision]

Standard

[Preoperative assessment of intraocular lens corrected vision]. / Kusel, Reinhard; Rassow, B.

In: KLIN MONATSBL AUGENH, Vol. 215, No. 2, 2, 1999, p. 127-131.

Research output: SCORING: Contribution to journalSCORING: Journal articleResearchpeer-review

Harvard

APA

Vancouver

Bibtex

@article{b193b933b92c41a8836aead2212f3494,
title = "[Preoperative assessment of intraocular lens corrected vision]",
abstract = "BACKGROUND: At present, preoperative estimation of the influence of intra-ocular lenses (IOL) on visual performance, that is not only based on visual acuity but on the whole contrast sensitivity function (CSF), is only possible with high efforts. METHODS: We describe a method to evaluate the CSF of a patient after IOL implantation. The method is based on the knowledge of a normal subject's CSF, and the modulation transfer function of the IOL that can be measured or computed. RESULTS AND DISCUSSION: Comparison of computed and measured CSF with monofocal and multifocal IOL shows that the method allows prediction of visual performance after implantation of the IOL.",
author = "Reinhard Kusel and B Rassow",
year = "1999",
language = "Deutsch",
volume = "215",
pages = "127--131",
journal = "KLIN MONATSBL AUGENH",
issn = "0023-2165",
publisher = "Ferdinand Enke Verlag",
number = "2",

}

RIS

TY - JOUR

T1 - [Preoperative assessment of intraocular lens corrected vision]

AU - Kusel, Reinhard

AU - Rassow, B

PY - 1999

Y1 - 1999

N2 - BACKGROUND: At present, preoperative estimation of the influence of intra-ocular lenses (IOL) on visual performance, that is not only based on visual acuity but on the whole contrast sensitivity function (CSF), is only possible with high efforts. METHODS: We describe a method to evaluate the CSF of a patient after IOL implantation. The method is based on the knowledge of a normal subject's CSF, and the modulation transfer function of the IOL that can be measured or computed. RESULTS AND DISCUSSION: Comparison of computed and measured CSF with monofocal and multifocal IOL shows that the method allows prediction of visual performance after implantation of the IOL.

AB - BACKGROUND: At present, preoperative estimation of the influence of intra-ocular lenses (IOL) on visual performance, that is not only based on visual acuity but on the whole contrast sensitivity function (CSF), is only possible with high efforts. METHODS: We describe a method to evaluate the CSF of a patient after IOL implantation. The method is based on the knowledge of a normal subject's CSF, and the modulation transfer function of the IOL that can be measured or computed. RESULTS AND DISCUSSION: Comparison of computed and measured CSF with monofocal and multifocal IOL shows that the method allows prediction of visual performance after implantation of the IOL.

M3 - SCORING: Zeitschriftenaufsatz

VL - 215

SP - 127

EP - 131

JO - KLIN MONATSBL AUGENH

JF - KLIN MONATSBL AUGENH

SN - 0023-2165

IS - 2

M1 - 2

ER -