Predicting Risk in Transcatheter Aortic Valve Implantation: Comparative Analysis of EuroSCORE II and Established Risk Stratification Tools

Standard

Harvard

APA

Vancouver

Bibtex

@article{658a0a078a4645d48ce880dfce3b8edb,
title = "Predicting Risk in Transcatheter Aortic Valve Implantation: Comparative Analysis of EuroSCORE II and Established Risk Stratification Tools",
abstract = "Background The logistic European System for Cardiac Operative Risk Evaluation (logEuroSCORE) II was developed to improve prediction of mortality in cardiac surgery. However, no specific tools are available for risk prediction in transcatheter aortic valve implantation (TAVI). The recently introduced EuroSCORE II was compared with established risk scores. Patients and Methods We assessed 457 consecutive patients (80.5 ± 7.1 years, 52.3% female) undergoing TAVI. Preoperative risk evaluation included logEuroSCORE I, EuroSCORE II, Society of Thoracic Surgeons (STS), Ambler, and Parsonnet scores. Validity was assessed by receiver-operating characteristic (ROC) and area under the curve (AUC). Results A 30-day mortality was 9.6% (44/457). Calculated scores were logEuroSCORE I 22.0%, confidence interval (CI) 21.0 to 24.6; EuroSCORE II 7.0%, CI 6.4 to 8.1; STS 7.9%, CI 7.7 to 9.5; Ambler score 6.9%, CI 5.7 to 7.0; and Parsonnet score 23.8%, CI 20.9 to 24.1. ROC analyses demonstrated no predictive value: logEuroSCORE I AUC 0.56, CI 0.47 to 0.65; EuroSCORE II AUC 0.54, CI 0.46 to 0.63; STS AUC 0.57, CI 0.49 to 0.66; Ambler AUC 0.52, CI 0.43 to 0.60; and Parsonnet AUC 0.51, CI 0.43 to 0.60. Accuracy and thresholds were measured on behalf of Youden index. Accuracy ranged between 44.2% (Parsonnet) and 66.3% (logEuroSCORE I). Thresholds were logEuroSCORE I 26%, EuroSCORE II 7%, STS 6%, Ambler 3%, and Parsonnet 19%. Conclusions No risk evaluation system provided acceptable predictive ability. Scores derived from conventional cardiac surgery failed in risk prediction for TAVI. Specific risk tools are required. Until available, estimation of risk has to rely on judgment of an interdisciplinary heart team regarding individual patient factors.",
author = "Miriam Silaschi and Lenard Conradi and Moritz Seiffert and Renate Schnabel and Gerhard Sch{\"o}n and Stefan Blankenberg and Hermann Reichenspurner and Patrick Diemert and Hendrik Treede",
note = "Georg Thieme Verlag KG Stuttgart · New York.",
year = "2015",
month = sep,
doi = "10.1055/s-0034-1389107",
language = "English",
volume = "63",
pages = "472--478",
journal = "THORAC CARDIOV SURG",
issn = "0171-6425",
publisher = "Georg Thieme Verlag KG",
number = "6",

}

RIS

TY - JOUR

T1 - Predicting Risk in Transcatheter Aortic Valve Implantation: Comparative Analysis of EuroSCORE II and Established Risk Stratification Tools

AU - Silaschi, Miriam

AU - Conradi, Lenard

AU - Seiffert, Moritz

AU - Schnabel, Renate

AU - Schön, Gerhard

AU - Blankenberg, Stefan

AU - Reichenspurner, Hermann

AU - Diemert, Patrick

AU - Treede, Hendrik

N1 - Georg Thieme Verlag KG Stuttgart · New York.

PY - 2015/9

Y1 - 2015/9

N2 - Background The logistic European System for Cardiac Operative Risk Evaluation (logEuroSCORE) II was developed to improve prediction of mortality in cardiac surgery. However, no specific tools are available for risk prediction in transcatheter aortic valve implantation (TAVI). The recently introduced EuroSCORE II was compared with established risk scores. Patients and Methods We assessed 457 consecutive patients (80.5 ± 7.1 years, 52.3% female) undergoing TAVI. Preoperative risk evaluation included logEuroSCORE I, EuroSCORE II, Society of Thoracic Surgeons (STS), Ambler, and Parsonnet scores. Validity was assessed by receiver-operating characteristic (ROC) and area under the curve (AUC). Results A 30-day mortality was 9.6% (44/457). Calculated scores were logEuroSCORE I 22.0%, confidence interval (CI) 21.0 to 24.6; EuroSCORE II 7.0%, CI 6.4 to 8.1; STS 7.9%, CI 7.7 to 9.5; Ambler score 6.9%, CI 5.7 to 7.0; and Parsonnet score 23.8%, CI 20.9 to 24.1. ROC analyses demonstrated no predictive value: logEuroSCORE I AUC 0.56, CI 0.47 to 0.65; EuroSCORE II AUC 0.54, CI 0.46 to 0.63; STS AUC 0.57, CI 0.49 to 0.66; Ambler AUC 0.52, CI 0.43 to 0.60; and Parsonnet AUC 0.51, CI 0.43 to 0.60. Accuracy and thresholds were measured on behalf of Youden index. Accuracy ranged between 44.2% (Parsonnet) and 66.3% (logEuroSCORE I). Thresholds were logEuroSCORE I 26%, EuroSCORE II 7%, STS 6%, Ambler 3%, and Parsonnet 19%. Conclusions No risk evaluation system provided acceptable predictive ability. Scores derived from conventional cardiac surgery failed in risk prediction for TAVI. Specific risk tools are required. Until available, estimation of risk has to rely on judgment of an interdisciplinary heart team regarding individual patient factors.

AB - Background The logistic European System for Cardiac Operative Risk Evaluation (logEuroSCORE) II was developed to improve prediction of mortality in cardiac surgery. However, no specific tools are available for risk prediction in transcatheter aortic valve implantation (TAVI). The recently introduced EuroSCORE II was compared with established risk scores. Patients and Methods We assessed 457 consecutive patients (80.5 ± 7.1 years, 52.3% female) undergoing TAVI. Preoperative risk evaluation included logEuroSCORE I, EuroSCORE II, Society of Thoracic Surgeons (STS), Ambler, and Parsonnet scores. Validity was assessed by receiver-operating characteristic (ROC) and area under the curve (AUC). Results A 30-day mortality was 9.6% (44/457). Calculated scores were logEuroSCORE I 22.0%, confidence interval (CI) 21.0 to 24.6; EuroSCORE II 7.0%, CI 6.4 to 8.1; STS 7.9%, CI 7.7 to 9.5; Ambler score 6.9%, CI 5.7 to 7.0; and Parsonnet score 23.8%, CI 20.9 to 24.1. ROC analyses demonstrated no predictive value: logEuroSCORE I AUC 0.56, CI 0.47 to 0.65; EuroSCORE II AUC 0.54, CI 0.46 to 0.63; STS AUC 0.57, CI 0.49 to 0.66; Ambler AUC 0.52, CI 0.43 to 0.60; and Parsonnet AUC 0.51, CI 0.43 to 0.60. Accuracy and thresholds were measured on behalf of Youden index. Accuracy ranged between 44.2% (Parsonnet) and 66.3% (logEuroSCORE I). Thresholds were logEuroSCORE I 26%, EuroSCORE II 7%, STS 6%, Ambler 3%, and Parsonnet 19%. Conclusions No risk evaluation system provided acceptable predictive ability. Scores derived from conventional cardiac surgery failed in risk prediction for TAVI. Specific risk tools are required. Until available, estimation of risk has to rely on judgment of an interdisciplinary heart team regarding individual patient factors.

U2 - 10.1055/s-0034-1389107

DO - 10.1055/s-0034-1389107

M3 - SCORING: Journal article

C2 - 25191764

VL - 63

SP - 472

EP - 478

JO - THORAC CARDIOV SURG

JF - THORAC CARDIOV SURG

SN - 0171-6425

IS - 6

ER -