Performance measures for lower gastrointestinal endoscopy

Standard

Performance measures for lower gastrointestinal endoscopy : a European Society of Gastrointestinal Endoscopy (ESGE) Quality Improvement Initiative. / Kaminski, Michal F; Thomas-Gibson, Siwan; Bugajski, Marek; Bretthauer, Michael; Rees, Colin J; Dekker, Evelien; Hoff, Geir; Jover, Rodrigo; Suchanek, Stepan; Ferlitsch, Monika; Anderson, John; Roesch, Thomas; Hultcranz, Rolf; Racz, Istvan; Kuipers, Ernst J; Garborg, Kjetil; East, James E; Rupinski, Maciej; Seip, Birgitte; Bennett, Cathy; Senore, Carlo; Minozzi, Silvia; Bisschops, Raf; Domagk, Dirk; Valori, Roland; Spada, Cristiano; Hassan, Cesare; Dinis-Ribeiro, Mario; Rutter, Matthew D.

In: ENDOSCOPY, Vol. 49, No. 4, 04.2017, p. 378-397.

Research output: SCORING: Contribution to journalSCORING: Journal articleResearchpeer-review

Harvard

Kaminski, MF, Thomas-Gibson, S, Bugajski, M, Bretthauer, M, Rees, CJ, Dekker, E, Hoff, G, Jover, R, Suchanek, S, Ferlitsch, M, Anderson, J, Roesch, T, Hultcranz, R, Racz, I, Kuipers, EJ, Garborg, K, East, JE, Rupinski, M, Seip, B, Bennett, C, Senore, C, Minozzi, S, Bisschops, R, Domagk, D, Valori, R, Spada, C, Hassan, C, Dinis-Ribeiro, M & Rutter, MD 2017, 'Performance measures for lower gastrointestinal endoscopy: a European Society of Gastrointestinal Endoscopy (ESGE) Quality Improvement Initiative', ENDOSCOPY, vol. 49, no. 4, pp. 378-397. https://doi.org/10.1055/s-0043-103411

APA

Kaminski, M. F., Thomas-Gibson, S., Bugajski, M., Bretthauer, M., Rees, C. J., Dekker, E., Hoff, G., Jover, R., Suchanek, S., Ferlitsch, M., Anderson, J., Roesch, T., Hultcranz, R., Racz, I., Kuipers, E. J., Garborg, K., East, J. E., Rupinski, M., Seip, B., ... Rutter, M. D. (2017). Performance measures for lower gastrointestinal endoscopy: a European Society of Gastrointestinal Endoscopy (ESGE) Quality Improvement Initiative. ENDOSCOPY, 49(4), 378-397. https://doi.org/10.1055/s-0043-103411

Vancouver

Bibtex

@article{d2985fd68f3b480f9a53ad320e06a2f2,
title = "Performance measures for lower gastrointestinal endoscopy: a European Society of Gastrointestinal Endoscopy (ESGE) Quality Improvement Initiative",
abstract = "The European Society of Gastrointestinal Endoscopy and United European Gastroenterology present a short list of key performance measures for lower gastrointestinal endoscopy. We recommend that endoscopy services across Europe adopt the following seven key performance measures for lower gastrointestinal endoscopy for measurement and evaluation in daily practice at a center and endoscopist level:1Rate of adequate bowel preparation (minimum standard 90 %);2 Cecal intubation rate (minimum standard 90 %);3Adenoma detection rate (minimum standard 25 %);4Appropriate polypectomy technique (minimum standard 80 %);5Complication rate (minimum standard not set);6Patient experience (minimum standard not set);7Appropriate post-polypectomy surveillance recommendations (minimum standard not set). Other identified performance measures have been listed as less relevant based on an assessment of their importance, scientific acceptability, feasibility, usability, and comparison to competing measures.",
keywords = "Adenoma, Appointments and Schedules, Cathartics, Cecum, Colonic Polyps, Colonoscopy, Colorectal Neoplasms, Humans, Intubation, Patient Satisfaction, Patient Selection, Population Surveillance, Postoperative Complications, Time Factors, Journal Article, Practice Guideline",
author = "Kaminski, {Michal F} and Siwan Thomas-Gibson and Marek Bugajski and Michael Bretthauer and Rees, {Colin J} and Evelien Dekker and Geir Hoff and Rodrigo Jover and Stepan Suchanek and Monika Ferlitsch and John Anderson and Thomas Roesch and Rolf Hultcranz and Istvan Racz and Kuipers, {Ernst J} and Kjetil Garborg and East, {James E} and Maciej Rupinski and Birgitte Seip and Cathy Bennett and Carlo Senore and Silvia Minozzi and Raf Bisschops and Dirk Domagk and Roland Valori and Cristiano Spada and Cesare Hassan and Mario Dinis-Ribeiro and Rutter, {Matthew D}",
note = "{\textcopyright} Georg Thieme Verlag KG Stuttgart · New York.",
year = "2017",
month = apr,
doi = "10.1055/s-0043-103411",
language = "English",
volume = "49",
pages = "378--397",
journal = "ENDOSCOPY",
issn = "0013-726X",
publisher = "Georg Thieme Verlag KG",
number = "4",

}

RIS

TY - JOUR

T1 - Performance measures for lower gastrointestinal endoscopy

T2 - a European Society of Gastrointestinal Endoscopy (ESGE) Quality Improvement Initiative

AU - Kaminski, Michal F

AU - Thomas-Gibson, Siwan

AU - Bugajski, Marek

AU - Bretthauer, Michael

AU - Rees, Colin J

AU - Dekker, Evelien

AU - Hoff, Geir

AU - Jover, Rodrigo

AU - Suchanek, Stepan

AU - Ferlitsch, Monika

AU - Anderson, John

AU - Roesch, Thomas

AU - Hultcranz, Rolf

AU - Racz, Istvan

AU - Kuipers, Ernst J

AU - Garborg, Kjetil

AU - East, James E

AU - Rupinski, Maciej

AU - Seip, Birgitte

AU - Bennett, Cathy

AU - Senore, Carlo

AU - Minozzi, Silvia

AU - Bisschops, Raf

AU - Domagk, Dirk

AU - Valori, Roland

AU - Spada, Cristiano

AU - Hassan, Cesare

AU - Dinis-Ribeiro, Mario

AU - Rutter, Matthew D

N1 - © Georg Thieme Verlag KG Stuttgart · New York.

PY - 2017/4

Y1 - 2017/4

N2 - The European Society of Gastrointestinal Endoscopy and United European Gastroenterology present a short list of key performance measures for lower gastrointestinal endoscopy. We recommend that endoscopy services across Europe adopt the following seven key performance measures for lower gastrointestinal endoscopy for measurement and evaluation in daily practice at a center and endoscopist level:1Rate of adequate bowel preparation (minimum standard 90 %);2 Cecal intubation rate (minimum standard 90 %);3Adenoma detection rate (minimum standard 25 %);4Appropriate polypectomy technique (minimum standard 80 %);5Complication rate (minimum standard not set);6Patient experience (minimum standard not set);7Appropriate post-polypectomy surveillance recommendations (minimum standard not set). Other identified performance measures have been listed as less relevant based on an assessment of their importance, scientific acceptability, feasibility, usability, and comparison to competing measures.

AB - The European Society of Gastrointestinal Endoscopy and United European Gastroenterology present a short list of key performance measures for lower gastrointestinal endoscopy. We recommend that endoscopy services across Europe adopt the following seven key performance measures for lower gastrointestinal endoscopy for measurement and evaluation in daily practice at a center and endoscopist level:1Rate of adequate bowel preparation (minimum standard 90 %);2 Cecal intubation rate (minimum standard 90 %);3Adenoma detection rate (minimum standard 25 %);4Appropriate polypectomy technique (minimum standard 80 %);5Complication rate (minimum standard not set);6Patient experience (minimum standard not set);7Appropriate post-polypectomy surveillance recommendations (minimum standard not set). Other identified performance measures have been listed as less relevant based on an assessment of their importance, scientific acceptability, feasibility, usability, and comparison to competing measures.

KW - Adenoma

KW - Appointments and Schedules

KW - Cathartics

KW - Cecum

KW - Colonic Polyps

KW - Colonoscopy

KW - Colorectal Neoplasms

KW - Humans

KW - Intubation

KW - Patient Satisfaction

KW - Patient Selection

KW - Population Surveillance

KW - Postoperative Complications

KW - Time Factors

KW - Journal Article

KW - Practice Guideline

U2 - 10.1055/s-0043-103411

DO - 10.1055/s-0043-103411

M3 - SCORING: Journal article

C2 - 28268235

VL - 49

SP - 378

EP - 397

JO - ENDOSCOPY

JF - ENDOSCOPY

SN - 0013-726X

IS - 4

ER -