Optimization and validation of a fully-integrated pulse sequence for modified look-locker inversion-recovery (MOLLI) T1 mapping of the heart.

Standard

Optimization and validation of a fully-integrated pulse sequence for modified look-locker inversion-recovery (MOLLI) T1 mapping of the heart. / Messroghli, Daniel R; Greiser, Andreas; Fröhlich, Mirko; Dietz, Rainer; Schulz-Menger, Jeanette.

In: J MAGN RESON IMAGING, Vol. 26, No. 4, 4, 2007, p. 1081-1086.

Research output: SCORING: Contribution to journalSCORING: Journal articleResearchpeer-review

Harvard

APA

Vancouver

Bibtex

@article{a3f15579c85947f881d9718476ca3cab,
title = "Optimization and validation of a fully-integrated pulse sequence for modified look-locker inversion-recovery (MOLLI) T1 mapping of the heart.",
abstract = "PURPOSE: To optimize and validate a fully-integrated version of modified Look-Locker inversion-recovery (MOLLI) for clinical single-breathhold cardiac T1 mapping. MATERIALS AND METHODS: A MOLLI variant allowing direct access to all pulse sequence parameters was implemented on a 1.5T MR system. Varying four critical sequence parameters, MOLLI was performed in eight gadolinium-doped agarose gel phantoms at different simulated heart rates. T1 values were derived for each variant and compared to nominal T1 values. Based on the results, MOLLI was performed in midcavity short-axis views of 20 healthy volunteers pre- and post-Gd-DTPA. RESULTS: In phantoms, a readout flip angle of 35 degrees , minimum TI of 100 msec, TI increment of 80 msec, and use of three pausing heart cycles allowed for most accurate and least heart rate-dependent T1 measurements. Using this pulse sequence scheme in humans, T1 relaxation times in normal myocardium were comparable to data from previous studies, and showed narrow ranges both pre- and postcontrast without heart rate dependency. CONCLUSION: We present an optimized implementation of MOLLI for fast T1 mapping with high spatial resolution, which can be integrated into routine imaging protocols. T1 accuracy is superior to the original set of pulse sequence parameters and heart rate dependency is avoided.",
author = "Messroghli, {Daniel R} and Andreas Greiser and Mirko Fr{\"o}hlich and Rainer Dietz and Jeanette Schulz-Menger",
year = "2007",
language = "Deutsch",
volume = "26",
pages = "1081--1086",
journal = "J MAGN RESON IMAGING",
issn = "1053-1807",
publisher = "John Wiley and Sons Inc.",
number = "4",

}

RIS

TY - JOUR

T1 - Optimization and validation of a fully-integrated pulse sequence for modified look-locker inversion-recovery (MOLLI) T1 mapping of the heart.

AU - Messroghli, Daniel R

AU - Greiser, Andreas

AU - Fröhlich, Mirko

AU - Dietz, Rainer

AU - Schulz-Menger, Jeanette

PY - 2007

Y1 - 2007

N2 - PURPOSE: To optimize and validate a fully-integrated version of modified Look-Locker inversion-recovery (MOLLI) for clinical single-breathhold cardiac T1 mapping. MATERIALS AND METHODS: A MOLLI variant allowing direct access to all pulse sequence parameters was implemented on a 1.5T MR system. Varying four critical sequence parameters, MOLLI was performed in eight gadolinium-doped agarose gel phantoms at different simulated heart rates. T1 values were derived for each variant and compared to nominal T1 values. Based on the results, MOLLI was performed in midcavity short-axis views of 20 healthy volunteers pre- and post-Gd-DTPA. RESULTS: In phantoms, a readout flip angle of 35 degrees , minimum TI of 100 msec, TI increment of 80 msec, and use of three pausing heart cycles allowed for most accurate and least heart rate-dependent T1 measurements. Using this pulse sequence scheme in humans, T1 relaxation times in normal myocardium were comparable to data from previous studies, and showed narrow ranges both pre- and postcontrast without heart rate dependency. CONCLUSION: We present an optimized implementation of MOLLI for fast T1 mapping with high spatial resolution, which can be integrated into routine imaging protocols. T1 accuracy is superior to the original set of pulse sequence parameters and heart rate dependency is avoided.

AB - PURPOSE: To optimize and validate a fully-integrated version of modified Look-Locker inversion-recovery (MOLLI) for clinical single-breathhold cardiac T1 mapping. MATERIALS AND METHODS: A MOLLI variant allowing direct access to all pulse sequence parameters was implemented on a 1.5T MR system. Varying four critical sequence parameters, MOLLI was performed in eight gadolinium-doped agarose gel phantoms at different simulated heart rates. T1 values were derived for each variant and compared to nominal T1 values. Based on the results, MOLLI was performed in midcavity short-axis views of 20 healthy volunteers pre- and post-Gd-DTPA. RESULTS: In phantoms, a readout flip angle of 35 degrees , minimum TI of 100 msec, TI increment of 80 msec, and use of three pausing heart cycles allowed for most accurate and least heart rate-dependent T1 measurements. Using this pulse sequence scheme in humans, T1 relaxation times in normal myocardium were comparable to data from previous studies, and showed narrow ranges both pre- and postcontrast without heart rate dependency. CONCLUSION: We present an optimized implementation of MOLLI for fast T1 mapping with high spatial resolution, which can be integrated into routine imaging protocols. T1 accuracy is superior to the original set of pulse sequence parameters and heart rate dependency is avoided.

M3 - SCORING: Zeitschriftenaufsatz

VL - 26

SP - 1081

EP - 1086

JO - J MAGN RESON IMAGING

JF - J MAGN RESON IMAGING

SN - 1053-1807

IS - 4

M1 - 4

ER -