Mechanical aspects of a multidirectional, angular stable osteosynthesis system and comparison with four conventional systems.

Standard

Mechanical aspects of a multidirectional, angular stable osteosynthesis system and comparison with four conventional systems. / Gbara, Ali; Heiland, Max; Schmelzle, Rainer; Blake, Felix.

In: J CRANIO MAXILL SURG, Vol. 36, No. 3, 3, 2008, p. 152-156.

Research output: SCORING: Contribution to journalSCORING: Journal articleResearchpeer-review

Harvard

APA

Vancouver

Bibtex

@article{beab2f74c47a4cbe8b86bcfe35670db7,
title = "Mechanical aspects of a multidirectional, angular stable osteosynthesis system and comparison with four conventional systems.",
abstract = "BACKGROUND: Following open reduction, internal fixation of fractures of the mandible is predominantly achieved using plates and screws. Today, a multitude of osteosynthesis systems are available on the market. One therapy modality, primarily developed for orthopaedic surgery, is using angular stable osteosynthesis plate systems. The dominating principle of these is the bond between screw and plate following insertion. This principle of an {"}internal fixateur{"} results in a more stable fixation of the fragments associated with less compression of the bone surfaces. MATERIAL: A new multidirectional osteosynthesis system (TiFix=Smartlock, Hamburg - Germany) was modified to fit the maxillofacial region and compared with four other well established osteosynthesis systems developed by Mondial, Medicon, Synthes, Leibinger-Stryker, one of these (Unilock by Synthes) being also angular stable. The resistance to deformation in varying directions was investigated following fixation in four different materials. RESULTS: The TiFix system proved more resistant to deformation even when mounted with fewer screws than the non-angular stable systems. CONCLUSION: This system results in greater stability even when fewer screws are used. For the clinician this means smaller access incisions, less soft tissue trauma, better aesthetic results, decreased duration of operation and a reduction of costs.",
author = "Ali Gbara and Max Heiland and Rainer Schmelzle and Felix Blake",
year = "2008",
language = "Deutsch",
volume = "36",
pages = "152--156",
journal = "J CRANIO MAXILL SURG",
issn = "1010-5182",
publisher = "Elsevier",
number = "3",

}

RIS

TY - JOUR

T1 - Mechanical aspects of a multidirectional, angular stable osteosynthesis system and comparison with four conventional systems.

AU - Gbara, Ali

AU - Heiland, Max

AU - Schmelzle, Rainer

AU - Blake, Felix

PY - 2008

Y1 - 2008

N2 - BACKGROUND: Following open reduction, internal fixation of fractures of the mandible is predominantly achieved using plates and screws. Today, a multitude of osteosynthesis systems are available on the market. One therapy modality, primarily developed for orthopaedic surgery, is using angular stable osteosynthesis plate systems. The dominating principle of these is the bond between screw and plate following insertion. This principle of an "internal fixateur" results in a more stable fixation of the fragments associated with less compression of the bone surfaces. MATERIAL: A new multidirectional osteosynthesis system (TiFix=Smartlock, Hamburg - Germany) was modified to fit the maxillofacial region and compared with four other well established osteosynthesis systems developed by Mondial, Medicon, Synthes, Leibinger-Stryker, one of these (Unilock by Synthes) being also angular stable. The resistance to deformation in varying directions was investigated following fixation in four different materials. RESULTS: The TiFix system proved more resistant to deformation even when mounted with fewer screws than the non-angular stable systems. CONCLUSION: This system results in greater stability even when fewer screws are used. For the clinician this means smaller access incisions, less soft tissue trauma, better aesthetic results, decreased duration of operation and a reduction of costs.

AB - BACKGROUND: Following open reduction, internal fixation of fractures of the mandible is predominantly achieved using plates and screws. Today, a multitude of osteosynthesis systems are available on the market. One therapy modality, primarily developed for orthopaedic surgery, is using angular stable osteosynthesis plate systems. The dominating principle of these is the bond between screw and plate following insertion. This principle of an "internal fixateur" results in a more stable fixation of the fragments associated with less compression of the bone surfaces. MATERIAL: A new multidirectional osteosynthesis system (TiFix=Smartlock, Hamburg - Germany) was modified to fit the maxillofacial region and compared with four other well established osteosynthesis systems developed by Mondial, Medicon, Synthes, Leibinger-Stryker, one of these (Unilock by Synthes) being also angular stable. The resistance to deformation in varying directions was investigated following fixation in four different materials. RESULTS: The TiFix system proved more resistant to deformation even when mounted with fewer screws than the non-angular stable systems. CONCLUSION: This system results in greater stability even when fewer screws are used. For the clinician this means smaller access incisions, less soft tissue trauma, better aesthetic results, decreased duration of operation and a reduction of costs.

M3 - SCORING: Zeitschriftenaufsatz

VL - 36

SP - 152

EP - 156

JO - J CRANIO MAXILL SURG

JF - J CRANIO MAXILL SURG

SN - 1010-5182

IS - 3

M1 - 3

ER -