Measurement of homoarginine in human and mouse plasma by LC-MS/MS and ELISA: a comparison and a biological application

Standard

Measurement of homoarginine in human and mouse plasma by LC-MS/MS and ELISA: a comparison and a biological application. / Cordts, Kathrin; Atzler, Dorothee; Qaderi, Vazhma; Sydow, Karsten; Böger, Rainer H; Choe, Chi-Un; Schwedhelm, Edzard.

In: AMINO ACIDS, Vol. 47, No. 9, 09.2015, p. 2015-22.

Research output: SCORING: Contribution to journalSCORING: Journal articleResearchpeer-review

Harvard

APA

Vancouver

Bibtex

@article{d0059e3c8f194c96b683625be5dd323f,
title = "Measurement of homoarginine in human and mouse plasma by LC-MS/MS and ELISA: a comparison and a biological application",
abstract = "Homoarginine (hArg) is a non-essential amino acid that was identified as a risk marker for cardiovascular disease. Several analytical methods have been described for the quantification of hArg in biological samples. The aim of this study was to compare a liquid chromatography-tandem mass spectrometric (LC-MS/MS) approach with a commercially available enzyme-linked immunosorbent assay (ELISA). Determination of hArg concentrations in ELISA calibration standards measured by both methods revealed a correlation coefficient r (2) of 0.99, for LC-MS/MS calibrators r (2) was 0.997. However, linear regression analysis between the two assays for hArg concentrations in human plasma samples revealed a correlation coefficient r (2) of 0.78. Plasma concentrations obtained from LC-MS/MS are on average 29 % higher than those by ELISA. We investigated the hArg-isobaric N (ε)-trimethyllysine as potential source for the higher observed values, but evaluation of mass spectra indicated that N (ε)-trimethyllysine did not interfere with hArg quantification in our LC-MS/MS method. Both quantification methods were applied to measure hArg in (1) a case-control study of acute coronary syndrome and (2) L-arginine:glycine amidinotransferase-deficient mice. Our LC-MS/MS and the commercially available ELISA assay are suitable for hArg measurement in human and mouse plasma, but different reference values for each method need to be considered.",
author = "Kathrin Cordts and Dorothee Atzler and Vazhma Qaderi and Karsten Sydow and B{\"o}ger, {Rainer H} and Chi-Un Choe and Edzard Schwedhelm",
year = "2015",
month = sep,
doi = "10.1007/s00726-015-2037-7",
language = "English",
volume = "47",
pages = "2015--22",
journal = "AMINO ACIDS",
issn = "0939-4451",
publisher = "Springer Wien",
number = "9",

}

RIS

TY - JOUR

T1 - Measurement of homoarginine in human and mouse plasma by LC-MS/MS and ELISA: a comparison and a biological application

AU - Cordts, Kathrin

AU - Atzler, Dorothee

AU - Qaderi, Vazhma

AU - Sydow, Karsten

AU - Böger, Rainer H

AU - Choe, Chi-Un

AU - Schwedhelm, Edzard

PY - 2015/9

Y1 - 2015/9

N2 - Homoarginine (hArg) is a non-essential amino acid that was identified as a risk marker for cardiovascular disease. Several analytical methods have been described for the quantification of hArg in biological samples. The aim of this study was to compare a liquid chromatography-tandem mass spectrometric (LC-MS/MS) approach with a commercially available enzyme-linked immunosorbent assay (ELISA). Determination of hArg concentrations in ELISA calibration standards measured by both methods revealed a correlation coefficient r (2) of 0.99, for LC-MS/MS calibrators r (2) was 0.997. However, linear regression analysis between the two assays for hArg concentrations in human plasma samples revealed a correlation coefficient r (2) of 0.78. Plasma concentrations obtained from LC-MS/MS are on average 29 % higher than those by ELISA. We investigated the hArg-isobaric N (ε)-trimethyllysine as potential source for the higher observed values, but evaluation of mass spectra indicated that N (ε)-trimethyllysine did not interfere with hArg quantification in our LC-MS/MS method. Both quantification methods were applied to measure hArg in (1) a case-control study of acute coronary syndrome and (2) L-arginine:glycine amidinotransferase-deficient mice. Our LC-MS/MS and the commercially available ELISA assay are suitable for hArg measurement in human and mouse plasma, but different reference values for each method need to be considered.

AB - Homoarginine (hArg) is a non-essential amino acid that was identified as a risk marker for cardiovascular disease. Several analytical methods have been described for the quantification of hArg in biological samples. The aim of this study was to compare a liquid chromatography-tandem mass spectrometric (LC-MS/MS) approach with a commercially available enzyme-linked immunosorbent assay (ELISA). Determination of hArg concentrations in ELISA calibration standards measured by both methods revealed a correlation coefficient r (2) of 0.99, for LC-MS/MS calibrators r (2) was 0.997. However, linear regression analysis between the two assays for hArg concentrations in human plasma samples revealed a correlation coefficient r (2) of 0.78. Plasma concentrations obtained from LC-MS/MS are on average 29 % higher than those by ELISA. We investigated the hArg-isobaric N (ε)-trimethyllysine as potential source for the higher observed values, but evaluation of mass spectra indicated that N (ε)-trimethyllysine did not interfere with hArg quantification in our LC-MS/MS method. Both quantification methods were applied to measure hArg in (1) a case-control study of acute coronary syndrome and (2) L-arginine:glycine amidinotransferase-deficient mice. Our LC-MS/MS and the commercially available ELISA assay are suitable for hArg measurement in human and mouse plasma, but different reference values for each method need to be considered.

U2 - 10.1007/s00726-015-2037-7

DO - 10.1007/s00726-015-2037-7

M3 - SCORING: Journal article

C2 - 26159673

VL - 47

SP - 2015

EP - 2022

JO - AMINO ACIDS

JF - AMINO ACIDS

SN - 0939-4451

IS - 9

ER -