Low-flow CO removal in combination with renal replacement therapy effectively reduces ventilation requirements in hypercapnic patients: a pilot study

Standard

Low-flow CO removal in combination with renal replacement therapy effectively reduces ventilation requirements in hypercapnic patients: a pilot study. / Nentwich, Jens; Wichmann, Dominic; Kluge, Stefan; Lindau, Simone; Mutlak, Haitham; John, Stefan.

In: ANN INTENSIVE CARE, Vol. 9, No. 1, 07.01.2019, p. 3.

Research output: SCORING: Contribution to journalSCORING: Journal articleResearchpeer-review

Harvard

APA

Vancouver

Bibtex

@article{0d5858e522dc45afb8c763af42d2ce1b,
title = "Low-flow CO removal in combination with renal replacement therapy effectively reduces ventilation requirements in hypercapnic patients: a pilot study",
abstract = "BACKGROUND: Lung-protective strategies are the cornerstone of mechanical ventilation in critically ill patients with both ARDS and other disorders. Extracorporeal CO2 removal (ECCO2R) may enhance lung protection by allowing even further reductions in tidal volumes and is effective in low-flow settings commonly used for renal replacement therapy. In this study, we describe for the first time the effects of a labeled and certified system combining ECCO2R and renal replacement therapy on pulmonary stress and strain in hypercapnic patients with renal failure.METHODS: Twenty patients were treated with the combined system which incorporates a membrane lung (0.32 m2) in a conventional renal replacement circuit. After changes in blood gases under ECCO2R were recorded, baseline hypercapnia was reestablished and the impact on ventilation parameters such as tidal volume and driving pressure was recorded.RESULTS: The system delivered ECCO2R at rate of 43.4 ± 14.1 ml/min, PaCO2 decreased from 68.3 ± 11.8 to 61.8 ± 11.5 mmHg (p < 0.05) and pH increased from 7.18 ± 0.09 to 7.22 ± 0.08 (p < 0.05). There was a significant reduction in ventilation requirements with a decrease in tidal volume from 6.2 ± 0.9 to 5.4 ± 1.1 ml/kg PBW (p < 0.05) corresponding to a decrease in plateau pressure from 30.6 ± 4.6 to 27.7 ± 4.1 cmH2O (p < 0.05) and a decrease in driving pressure from 18.3 ± 4.3 to 15.6 ± 3.9 cmH2O (p < 0.05), indicating reduced pulmonary stress and strain. No complications related to the procedure were observed.CONCLUSIONS: The investigated low-flow ECCO2R and renal replacement system can ameliorate respiratory acidosis and decrease ventilation requirements in hypercapnic patients with concomitant renal failure. Trial registration NCT02590575, registered 10/23/2015.",
keywords = "Journal Article",
author = "Jens Nentwich and Dominic Wichmann and Stefan Kluge and Simone Lindau and Haitham Mutlak and Stefan John",
year = "2019",
month = jan,
day = "7",
doi = "10.1186/s13613-019-0480-4",
language = "English",
volume = "9",
pages = "3",
journal = "ANN INTENSIVE CARE",
issn = "2110-5820",
publisher = "Springer-Verlag GmbH and Co. KG",
number = "1",

}

RIS

TY - JOUR

T1 - Low-flow CO removal in combination with renal replacement therapy effectively reduces ventilation requirements in hypercapnic patients: a pilot study

AU - Nentwich, Jens

AU - Wichmann, Dominic

AU - Kluge, Stefan

AU - Lindau, Simone

AU - Mutlak, Haitham

AU - John, Stefan

PY - 2019/1/7

Y1 - 2019/1/7

N2 - BACKGROUND: Lung-protective strategies are the cornerstone of mechanical ventilation in critically ill patients with both ARDS and other disorders. Extracorporeal CO2 removal (ECCO2R) may enhance lung protection by allowing even further reductions in tidal volumes and is effective in low-flow settings commonly used for renal replacement therapy. In this study, we describe for the first time the effects of a labeled and certified system combining ECCO2R and renal replacement therapy on pulmonary stress and strain in hypercapnic patients with renal failure.METHODS: Twenty patients were treated with the combined system which incorporates a membrane lung (0.32 m2) in a conventional renal replacement circuit. After changes in blood gases under ECCO2R were recorded, baseline hypercapnia was reestablished and the impact on ventilation parameters such as tidal volume and driving pressure was recorded.RESULTS: The system delivered ECCO2R at rate of 43.4 ± 14.1 ml/min, PaCO2 decreased from 68.3 ± 11.8 to 61.8 ± 11.5 mmHg (p < 0.05) and pH increased from 7.18 ± 0.09 to 7.22 ± 0.08 (p < 0.05). There was a significant reduction in ventilation requirements with a decrease in tidal volume from 6.2 ± 0.9 to 5.4 ± 1.1 ml/kg PBW (p < 0.05) corresponding to a decrease in plateau pressure from 30.6 ± 4.6 to 27.7 ± 4.1 cmH2O (p < 0.05) and a decrease in driving pressure from 18.3 ± 4.3 to 15.6 ± 3.9 cmH2O (p < 0.05), indicating reduced pulmonary stress and strain. No complications related to the procedure were observed.CONCLUSIONS: The investigated low-flow ECCO2R and renal replacement system can ameliorate respiratory acidosis and decrease ventilation requirements in hypercapnic patients with concomitant renal failure. Trial registration NCT02590575, registered 10/23/2015.

AB - BACKGROUND: Lung-protective strategies are the cornerstone of mechanical ventilation in critically ill patients with both ARDS and other disorders. Extracorporeal CO2 removal (ECCO2R) may enhance lung protection by allowing even further reductions in tidal volumes and is effective in low-flow settings commonly used for renal replacement therapy. In this study, we describe for the first time the effects of a labeled and certified system combining ECCO2R and renal replacement therapy on pulmonary stress and strain in hypercapnic patients with renal failure.METHODS: Twenty patients were treated with the combined system which incorporates a membrane lung (0.32 m2) in a conventional renal replacement circuit. After changes in blood gases under ECCO2R were recorded, baseline hypercapnia was reestablished and the impact on ventilation parameters such as tidal volume and driving pressure was recorded.RESULTS: The system delivered ECCO2R at rate of 43.4 ± 14.1 ml/min, PaCO2 decreased from 68.3 ± 11.8 to 61.8 ± 11.5 mmHg (p < 0.05) and pH increased from 7.18 ± 0.09 to 7.22 ± 0.08 (p < 0.05). There was a significant reduction in ventilation requirements with a decrease in tidal volume from 6.2 ± 0.9 to 5.4 ± 1.1 ml/kg PBW (p < 0.05) corresponding to a decrease in plateau pressure from 30.6 ± 4.6 to 27.7 ± 4.1 cmH2O (p < 0.05) and a decrease in driving pressure from 18.3 ± 4.3 to 15.6 ± 3.9 cmH2O (p < 0.05), indicating reduced pulmonary stress and strain. No complications related to the procedure were observed.CONCLUSIONS: The investigated low-flow ECCO2R and renal replacement system can ameliorate respiratory acidosis and decrease ventilation requirements in hypercapnic patients with concomitant renal failure. Trial registration NCT02590575, registered 10/23/2015.

KW - Journal Article

U2 - 10.1186/s13613-019-0480-4

DO - 10.1186/s13613-019-0480-4

M3 - SCORING: Journal article

C2 - 30617611

VL - 9

SP - 3

JO - ANN INTENSIVE CARE

JF - ANN INTENSIVE CARE

SN - 2110-5820

IS - 1

ER -