Local full-thickness skin graft of the donor arm-a novel technique for the reduction of donor site morbidity in radial forearm free flap

Standard

Local full-thickness skin graft of the donor arm-a novel technique for the reduction of donor site morbidity in radial forearm free flap. / Riecke, B; Assaf, A T; Heiland, M; Al-Dam, A; Gröbe, A; Blessmann, M; Wikner, J.

In: INT J ORAL MAX SURG, Vol. 44, No. 8, 21.03.2015, p. 937-941.

Research output: SCORING: Contribution to journalSCORING: Journal articleResearchpeer-review

Harvard

APA

Vancouver

Bibtex

@article{223ff036e86642248f742110574a7960,
title = "Local full-thickness skin graft of the donor arm-a novel technique for the reduction of donor site morbidity in radial forearm free flap",
abstract = "A novel technique to reduce donor site morbidity after radial forearm free flap (RFFF) harvest, using a local full-thickness skin graft (FTSG), is described. Thirty consecutive patients undergoing RFFF for head and neck reconstruction were enrolled in a prospective study. Donor site defect closure was performed with spindle-shaped FTSGs excised from the wavelike skin incision made for the vascular pedicle. Both the removal site of the FTSG on the volar forearm and the covered RFFF donor site healed uneventfully in 29 cases, with no impairment of function related to the skin graft. No skin graft failure and no exposure, tenting, or adherence of the flexor tendons occurred. All patients expressed satisfaction with postoperative pain, the functional outcome, and cosmetic appearance. Primary donor site defect closure could be achieved in all cases with the use of a local FTSG. This graft can be gained at the access incision for the vascular pedicle, avoids expansion of the incision for a local flap technique, and does not prolong wound healing, and thus reduces both donor site and graft site morbidity of the RFFF. This technique leads to an inconspicuous aesthetic result with no apparent relevant functional deficits and avoids the need for a second donor site.",
author = "B Riecke and Assaf, {A T} and M Heiland and A Al-Dam and A Gr{\"o}be and M Blessmann and J Wikner",
note = "Copyright {\textcopyright} 2015 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.",
year = "2015",
month = mar,
day = "21",
doi = "10.1016/j.ijom.2015.02.021",
language = "English",
volume = "44",
pages = "937--941",
journal = "INT J ORAL MAX SURG",
issn = "0901-5027",
publisher = "Churchill Livingstone",
number = "8",

}

RIS

TY - JOUR

T1 - Local full-thickness skin graft of the donor arm-a novel technique for the reduction of donor site morbidity in radial forearm free flap

AU - Riecke, B

AU - Assaf, A T

AU - Heiland, M

AU - Al-Dam, A

AU - Gröbe, A

AU - Blessmann, M

AU - Wikner, J

N1 - Copyright © 2015 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

PY - 2015/3/21

Y1 - 2015/3/21

N2 - A novel technique to reduce donor site morbidity after radial forearm free flap (RFFF) harvest, using a local full-thickness skin graft (FTSG), is described. Thirty consecutive patients undergoing RFFF for head and neck reconstruction were enrolled in a prospective study. Donor site defect closure was performed with spindle-shaped FTSGs excised from the wavelike skin incision made for the vascular pedicle. Both the removal site of the FTSG on the volar forearm and the covered RFFF donor site healed uneventfully in 29 cases, with no impairment of function related to the skin graft. No skin graft failure and no exposure, tenting, or adherence of the flexor tendons occurred. All patients expressed satisfaction with postoperative pain, the functional outcome, and cosmetic appearance. Primary donor site defect closure could be achieved in all cases with the use of a local FTSG. This graft can be gained at the access incision for the vascular pedicle, avoids expansion of the incision for a local flap technique, and does not prolong wound healing, and thus reduces both donor site and graft site morbidity of the RFFF. This technique leads to an inconspicuous aesthetic result with no apparent relevant functional deficits and avoids the need for a second donor site.

AB - A novel technique to reduce donor site morbidity after radial forearm free flap (RFFF) harvest, using a local full-thickness skin graft (FTSG), is described. Thirty consecutive patients undergoing RFFF for head and neck reconstruction were enrolled in a prospective study. Donor site defect closure was performed with spindle-shaped FTSGs excised from the wavelike skin incision made for the vascular pedicle. Both the removal site of the FTSG on the volar forearm and the covered RFFF donor site healed uneventfully in 29 cases, with no impairment of function related to the skin graft. No skin graft failure and no exposure, tenting, or adherence of the flexor tendons occurred. All patients expressed satisfaction with postoperative pain, the functional outcome, and cosmetic appearance. Primary donor site defect closure could be achieved in all cases with the use of a local FTSG. This graft can be gained at the access incision for the vascular pedicle, avoids expansion of the incision for a local flap technique, and does not prolong wound healing, and thus reduces both donor site and graft site morbidity of the RFFF. This technique leads to an inconspicuous aesthetic result with no apparent relevant functional deficits and avoids the need for a second donor site.

U2 - 10.1016/j.ijom.2015.02.021

DO - 10.1016/j.ijom.2015.02.021

M3 - SCORING: Journal article

C2 - 25804895

VL - 44

SP - 937

EP - 941

JO - INT J ORAL MAX SURG

JF - INT J ORAL MAX SURG

SN - 0901-5027

IS - 8

ER -