Is visual evaluation of aneurysm coiling a reliable study end point? Systematic review and meta-analysis

Standard

Is visual evaluation of aneurysm coiling a reliable study end point? Systematic review and meta-analysis. / Ernst, Marielle; Yoo, Albert J; Kriston, Levente; Schönfeld, Michael H; Vettorazzi, Eik; Fiehler, Jens.

In: STROKE, Vol. 46, No. 6, 06.2015, p. 1574-81.

Research output: SCORING: Contribution to journalSCORING: Journal articleResearchpeer-review

Harvard

APA

Vancouver

Bibtex

@article{6da05c26200c4d23a19545ee4552e100,
title = "Is visual evaluation of aneurysm coiling a reliable study end point? Systematic review and meta-analysis",
abstract = "BACKGROUND AND PURPOSE: Angiographic occlusion as a surrogate marker of satisfactory aneurysm treatment is commonly used in clinical trials although some pitfalls have to be considered. To investigate the inter-rater reliability of visual rating of aneurysm occlusion as study end point, we performed a systematic review and meta-analysis.METHODS: Electronic databases (MEDLINE, EMBASE, PubMed, and the Cochrane Library) were searched up to June 2014. Assessment of risk for bias was based on the Quality Appraisal Tool for Studies of Diagnostic Reliability and the Guidelines for Reporting Reliability and Agreement studies. Inter-rater reliability estimates were pooled across studies using meta-analysis, and the influence of several factors (eg, imaging methods, grading scales, and occlusion rate) was tested with meta-regression.RESULTS: From 1193 titles, 644 abstracts and 87 full-text versions were reviewed. Twenty-six articles met the inclusion criteria and provided 77 reliability estimates. Twenty-one different rating scales were used, and statistical analysis varied. Mean inter-rater agreement of the pooled studies was substantial (κ=0.65; 95% confidence interval, 0.60-0.69). Reliability varied significantly as a function of imaging methods, grading scales, occlusion rates, and their interaction. Observer agreement substantially increased with increasing occlusion rate in digital subtraction angiography but not in MR angiography. Reliability was higher in studies using 2- or 3-value grading scales than in studies with 4-value grading scales.CONCLUSIONS: There is significant heterogeneity between studies evaluating the reliability of visual evaluation of aneurysm coiling. On the basis of our analysis, we found that the combination of magnetic resonance angiography, 3-value grading scale, and 2 trained raters seems most promising for usage as surrogate study end points.",
keywords = "Cerebral Angiography, Female, Humans, Intracranial Aneurysm, MEDLINE, Magnetic Resonance Angiography, Male",
author = "Marielle Ernst and Yoo, {Albert J} and Levente Kriston and Sch{\"o}nfeld, {Michael H} and Eik Vettorazzi and Jens Fiehler",
note = "{\textcopyright} 2015 American Heart Association, Inc.",
year = "2015",
month = jun,
doi = "10.1161/STROKEAHA.114.008513",
language = "English",
volume = "46",
pages = "1574--81",
journal = "STROKE",
issn = "0039-2499",
publisher = "Lippincott Williams and Wilkins",
number = "6",

}

RIS

TY - JOUR

T1 - Is visual evaluation of aneurysm coiling a reliable study end point? Systematic review and meta-analysis

AU - Ernst, Marielle

AU - Yoo, Albert J

AU - Kriston, Levente

AU - Schönfeld, Michael H

AU - Vettorazzi, Eik

AU - Fiehler, Jens

N1 - © 2015 American Heart Association, Inc.

PY - 2015/6

Y1 - 2015/6

N2 - BACKGROUND AND PURPOSE: Angiographic occlusion as a surrogate marker of satisfactory aneurysm treatment is commonly used in clinical trials although some pitfalls have to be considered. To investigate the inter-rater reliability of visual rating of aneurysm occlusion as study end point, we performed a systematic review and meta-analysis.METHODS: Electronic databases (MEDLINE, EMBASE, PubMed, and the Cochrane Library) were searched up to June 2014. Assessment of risk for bias was based on the Quality Appraisal Tool for Studies of Diagnostic Reliability and the Guidelines for Reporting Reliability and Agreement studies. Inter-rater reliability estimates were pooled across studies using meta-analysis, and the influence of several factors (eg, imaging methods, grading scales, and occlusion rate) was tested with meta-regression.RESULTS: From 1193 titles, 644 abstracts and 87 full-text versions were reviewed. Twenty-six articles met the inclusion criteria and provided 77 reliability estimates. Twenty-one different rating scales were used, and statistical analysis varied. Mean inter-rater agreement of the pooled studies was substantial (κ=0.65; 95% confidence interval, 0.60-0.69). Reliability varied significantly as a function of imaging methods, grading scales, occlusion rates, and their interaction. Observer agreement substantially increased with increasing occlusion rate in digital subtraction angiography but not in MR angiography. Reliability was higher in studies using 2- or 3-value grading scales than in studies with 4-value grading scales.CONCLUSIONS: There is significant heterogeneity between studies evaluating the reliability of visual evaluation of aneurysm coiling. On the basis of our analysis, we found that the combination of magnetic resonance angiography, 3-value grading scale, and 2 trained raters seems most promising for usage as surrogate study end points.

AB - BACKGROUND AND PURPOSE: Angiographic occlusion as a surrogate marker of satisfactory aneurysm treatment is commonly used in clinical trials although some pitfalls have to be considered. To investigate the inter-rater reliability of visual rating of aneurysm occlusion as study end point, we performed a systematic review and meta-analysis.METHODS: Electronic databases (MEDLINE, EMBASE, PubMed, and the Cochrane Library) were searched up to June 2014. Assessment of risk for bias was based on the Quality Appraisal Tool for Studies of Diagnostic Reliability and the Guidelines for Reporting Reliability and Agreement studies. Inter-rater reliability estimates were pooled across studies using meta-analysis, and the influence of several factors (eg, imaging methods, grading scales, and occlusion rate) was tested with meta-regression.RESULTS: From 1193 titles, 644 abstracts and 87 full-text versions were reviewed. Twenty-six articles met the inclusion criteria and provided 77 reliability estimates. Twenty-one different rating scales were used, and statistical analysis varied. Mean inter-rater agreement of the pooled studies was substantial (κ=0.65; 95% confidence interval, 0.60-0.69). Reliability varied significantly as a function of imaging methods, grading scales, occlusion rates, and their interaction. Observer agreement substantially increased with increasing occlusion rate in digital subtraction angiography but not in MR angiography. Reliability was higher in studies using 2- or 3-value grading scales than in studies with 4-value grading scales.CONCLUSIONS: There is significant heterogeneity between studies evaluating the reliability of visual evaluation of aneurysm coiling. On the basis of our analysis, we found that the combination of magnetic resonance angiography, 3-value grading scale, and 2 trained raters seems most promising for usage as surrogate study end points.

KW - Cerebral Angiography

KW - Female

KW - Humans

KW - Intracranial Aneurysm

KW - MEDLINE

KW - Magnetic Resonance Angiography

KW - Male

U2 - 10.1161/STROKEAHA.114.008513

DO - 10.1161/STROKEAHA.114.008513

M3 - SCORING: Journal article

C2 - 25944331

VL - 46

SP - 1574

EP - 1581

JO - STROKE

JF - STROKE

SN - 0039-2499

IS - 6

ER -