Influence of femoral anteversion on proximal femoral loading: measurement and simulation in four patients.

Standard

Influence of femoral anteversion on proximal femoral loading: measurement and simulation in four patients. / Heller, M O; Bergmann, G; Deuretzbacher, Georg; Claes, L; Haas, N P; Duda, G N.

In: CLIN BIOMECH, Vol. 16, No. 8, 8, 2001, p. 644-649.

Research output: SCORING: Contribution to journalSCORING: Journal articleResearchpeer-review

Harvard

Heller, MO, Bergmann, G, Deuretzbacher, G, Claes, L, Haas, NP & Duda, GN 2001, 'Influence of femoral anteversion on proximal femoral loading: measurement and simulation in four patients.', CLIN BIOMECH, vol. 16, no. 8, 8, pp. 644-649. <http://www.ncbi.nlm.nih.gov/pubmed/11535345?dopt=Citation>

APA

Heller, M. O., Bergmann, G., Deuretzbacher, G., Claes, L., Haas, N. P., & Duda, G. N. (2001). Influence of femoral anteversion on proximal femoral loading: measurement and simulation in four patients. CLIN BIOMECH, 16(8), 644-649. [8]. http://www.ncbi.nlm.nih.gov/pubmed/11535345?dopt=Citation

Vancouver

Heller MO, Bergmann G, Deuretzbacher G, Claes L, Haas NP, Duda GN. Influence of femoral anteversion on proximal femoral loading: measurement and simulation in four patients. CLIN BIOMECH. 2001;16(8):644-649. 8.

Bibtex

@article{7324e5d41e5c4c229ec0b29b6d995d61,
title = "Influence of femoral anteversion on proximal femoral loading: measurement and simulation in four patients.",
abstract = "OBJECTIVE: The aim of this study was to determine the loading of the proximal femur during daily activities and to quantify the influence of femoral anteversion. DESIGN: This study combined experimental and analytical approaches to determine the in vivo loading at the hip joint. A numerical musculo-skeletal model was validated against measured in vivo hip contact forces and then used to analyse the influence of anteversion on the loading conditions in the femur. BACKGROUND: Musculo-skeletal loading of long bones is essential for joint replacement and fracture healing. Although joint contact forces have previously been measured in selected patients, the interaction between femoral anteversion and the associated musculo-skeletal loading environment remains unknown. METHODS: The gait of four patients with force measuring hip prostheses was analysed during walking and stair-climbing. Musculo-skeletal loading was determined using individual numerical models by minimising the sum of the muscle forces. RESULTS: Experimentally and numerically determined hip contact forces agreed both qualitatively and quantitatively. Muscle activity resulted in compression of the femur and small shear forces in the meta- and epi-physeal regions. Increasing the anteversion to an angle of 30 degrees increased hip contact forces and bending moments up to 28%. CONCLUSIONS: This study has shown that femoral anteversion has a strong influence on the musculo-skeletal loading environment in the proximal femur. RELEVANCE: Detailed musculo-skeletal modelling may allow pre-surgical, patient specific optimisation of loading on implant, bone and soft tissues.",
author = "Heller, {M O} and G Bergmann and Georg Deuretzbacher and L Claes and Haas, {N P} and Duda, {G N}",
year = "2001",
language = "Deutsch",
volume = "16",
pages = "644--649",
journal = "CLIN BIOMECH",
issn = "0268-0033",
publisher = "Elsevier Limited",
number = "8",

}

RIS

TY - JOUR

T1 - Influence of femoral anteversion on proximal femoral loading: measurement and simulation in four patients.

AU - Heller, M O

AU - Bergmann, G

AU - Deuretzbacher, Georg

AU - Claes, L

AU - Haas, N P

AU - Duda, G N

PY - 2001

Y1 - 2001

N2 - OBJECTIVE: The aim of this study was to determine the loading of the proximal femur during daily activities and to quantify the influence of femoral anteversion. DESIGN: This study combined experimental and analytical approaches to determine the in vivo loading at the hip joint. A numerical musculo-skeletal model was validated against measured in vivo hip contact forces and then used to analyse the influence of anteversion on the loading conditions in the femur. BACKGROUND: Musculo-skeletal loading of long bones is essential for joint replacement and fracture healing. Although joint contact forces have previously been measured in selected patients, the interaction between femoral anteversion and the associated musculo-skeletal loading environment remains unknown. METHODS: The gait of four patients with force measuring hip prostheses was analysed during walking and stair-climbing. Musculo-skeletal loading was determined using individual numerical models by minimising the sum of the muscle forces. RESULTS: Experimentally and numerically determined hip contact forces agreed both qualitatively and quantitatively. Muscle activity resulted in compression of the femur and small shear forces in the meta- and epi-physeal regions. Increasing the anteversion to an angle of 30 degrees increased hip contact forces and bending moments up to 28%. CONCLUSIONS: This study has shown that femoral anteversion has a strong influence on the musculo-skeletal loading environment in the proximal femur. RELEVANCE: Detailed musculo-skeletal modelling may allow pre-surgical, patient specific optimisation of loading on implant, bone and soft tissues.

AB - OBJECTIVE: The aim of this study was to determine the loading of the proximal femur during daily activities and to quantify the influence of femoral anteversion. DESIGN: This study combined experimental and analytical approaches to determine the in vivo loading at the hip joint. A numerical musculo-skeletal model was validated against measured in vivo hip contact forces and then used to analyse the influence of anteversion on the loading conditions in the femur. BACKGROUND: Musculo-skeletal loading of long bones is essential for joint replacement and fracture healing. Although joint contact forces have previously been measured in selected patients, the interaction between femoral anteversion and the associated musculo-skeletal loading environment remains unknown. METHODS: The gait of four patients with force measuring hip prostheses was analysed during walking and stair-climbing. Musculo-skeletal loading was determined using individual numerical models by minimising the sum of the muscle forces. RESULTS: Experimentally and numerically determined hip contact forces agreed both qualitatively and quantitatively. Muscle activity resulted in compression of the femur and small shear forces in the meta- and epi-physeal regions. Increasing the anteversion to an angle of 30 degrees increased hip contact forces and bending moments up to 28%. CONCLUSIONS: This study has shown that femoral anteversion has a strong influence on the musculo-skeletal loading environment in the proximal femur. RELEVANCE: Detailed musculo-skeletal modelling may allow pre-surgical, patient specific optimisation of loading on implant, bone and soft tissues.

M3 - SCORING: Zeitschriftenaufsatz

VL - 16

SP - 644

EP - 649

JO - CLIN BIOMECH

JF - CLIN BIOMECH

SN - 0268-0033

IS - 8

M1 - 8

ER -