Impact of probe-induced abdominal compression on two-dimensional shear wave elastography measurement of split liver transplants in children
Standard
Impact of probe-induced abdominal compression on two-dimensional shear wave elastography measurement of split liver transplants in children. / Groth, Michael; Fischer, Lutz; Herden, Uta; Brinkert, Florian; Beime, Jan; Deindl, Philipp; Adam, Gerhard; Herrmann, Jochen.
In: ROFO-FORTSCHR RONTG, Vol. 195, No. 10, 10.2023, p. 905-912.Research output: SCORING: Contribution to journal › SCORING: Journal article › Research › peer-review
Harvard
APA
Vancouver
Bibtex
}
RIS
TY - JOUR
T1 - Impact of probe-induced abdominal compression on two-dimensional shear wave elastography measurement of split liver transplants in children
AU - Groth, Michael
AU - Fischer, Lutz
AU - Herden, Uta
AU - Brinkert, Florian
AU - Beime, Jan
AU - Deindl, Philipp
AU - Adam, Gerhard
AU - Herrmann, Jochen
N1 - Thieme. All rights reserved.
PY - 2023/10
Y1 - 2023/10
N2 - PURPOSE: To evaluate the effect of probe-induced abdominal compression of split liver transplants (SLT) in children on 2D-shear wave elastography (SWE) values.MATERIALS AND METHODS: Data from 11 children (4.7 ± 4.8 years) who had undergone SLT and SWE were evaluated retrospectively. Elastograms were obtained with probes placed in an epigastric, midline position on the abdominal wall, with no and slight compression, using convex and linear transducers. For each identically positioned probe and condition, 12 serial elastograms were obtained and the SLT diameter was measured. Liver stiffness and degree of SLT compression were compared.RESULTS: Slight probe pressure resulted in SLT compression, with a shorter distance between the cutis and the posterior margin of the liver transplant than in the measurement with no pressure (curved array, 5.0 ± 1.1 vs. 5.9 ± 1.3 cm, mean compression 15 %± 8 %; linear array, 4.7 ± 0.9 vs. 5.3 ± 1.0 cm, mean compression 12 %± 8 %; both p < 0.0001). The median liver stiffness was significantly greater with slight pressure than with no pressure (curved transducer, 13.38 ± 3.0 vs. 7.02 ± 1.7 kPa, p < 0.0001; linear transducer, 18.53 ± 7.1 vs. 9.03 ± 1.5 kPa, p = 0.0003).CONCLUSION: Slight abdominal compression can significantly increase SWE values in children with left-lateral SLT. To obtain meaningful results and reduce operator dependency in free-hand examinations, probe pressure must be controlled carefully.KEY POINTS: · Probe-induced compression can increase elastography values in split liver transplants in children. · In free-hand examination, probe pressure must be controlled carefully. · Pressure loading can be determined indirectly by the anteroposterior transplant diameter.CITATION FORMAT: · Groth M, Fischer L, Herden U et al. Impact of probe-induced abdominal compression on two-dimensional shear wave elastography measurement of split liver transplants in children. Fortschr Röntgenstr 2023; 195: 905 - 912.
AB - PURPOSE: To evaluate the effect of probe-induced abdominal compression of split liver transplants (SLT) in children on 2D-shear wave elastography (SWE) values.MATERIALS AND METHODS: Data from 11 children (4.7 ± 4.8 years) who had undergone SLT and SWE were evaluated retrospectively. Elastograms were obtained with probes placed in an epigastric, midline position on the abdominal wall, with no and slight compression, using convex and linear transducers. For each identically positioned probe and condition, 12 serial elastograms were obtained and the SLT diameter was measured. Liver stiffness and degree of SLT compression were compared.RESULTS: Slight probe pressure resulted in SLT compression, with a shorter distance between the cutis and the posterior margin of the liver transplant than in the measurement with no pressure (curved array, 5.0 ± 1.1 vs. 5.9 ± 1.3 cm, mean compression 15 %± 8 %; linear array, 4.7 ± 0.9 vs. 5.3 ± 1.0 cm, mean compression 12 %± 8 %; both p < 0.0001). The median liver stiffness was significantly greater with slight pressure than with no pressure (curved transducer, 13.38 ± 3.0 vs. 7.02 ± 1.7 kPa, p < 0.0001; linear transducer, 18.53 ± 7.1 vs. 9.03 ± 1.5 kPa, p = 0.0003).CONCLUSION: Slight abdominal compression can significantly increase SWE values in children with left-lateral SLT. To obtain meaningful results and reduce operator dependency in free-hand examinations, probe pressure must be controlled carefully.KEY POINTS: · Probe-induced compression can increase elastography values in split liver transplants in children. · In free-hand examination, probe pressure must be controlled carefully. · Pressure loading can be determined indirectly by the anteroposterior transplant diameter.CITATION FORMAT: · Groth M, Fischer L, Herden U et al. Impact of probe-induced abdominal compression on two-dimensional shear wave elastography measurement of split liver transplants in children. Fortschr Röntgenstr 2023; 195: 905 - 912.
U2 - 10.1055/a-2049-9369
DO - 10.1055/a-2049-9369
M3 - SCORING: Journal article
C2 - 37137318
VL - 195
SP - 905
EP - 912
JO - ROFO-FORTSCHR RONTG
JF - ROFO-FORTSCHR RONTG
SN - 1438-9029
IS - 10
ER -