Haemodynamic benefits of rapid deployment aortic valve replacement via a minimally invasive approach: 1-year results of a prospective multicentre randomized controlled trial

Standard

Haemodynamic benefits of rapid deployment aortic valve replacement via a minimally invasive approach: 1-year results of a prospective multicentre randomized controlled trial. / Borger, Michael A; Dohmen, Pascal M; Knosalla, Christoph; Hammerschmidt, Robert; Merk, Denis R; Richter, Markus; Doenst, Torsten; Conradi, Lenard; Treede, Hendrik; Moustafine, Vadim; Holzhey, David M; Duhay, Francis; Strauch, Justus.

In: EUR J CARDIO-THORAC, Vol. 50, No. 4, 10.2016, p. 713-720.

Research output: SCORING: Contribution to journalSCORING: Journal articleResearchpeer-review

Harvard

Borger, MA, Dohmen, PM, Knosalla, C, Hammerschmidt, R, Merk, DR, Richter, M, Doenst, T, Conradi, L, Treede, H, Moustafine, V, Holzhey, DM, Duhay, F & Strauch, J 2016, 'Haemodynamic benefits of rapid deployment aortic valve replacement via a minimally invasive approach: 1-year results of a prospective multicentre randomized controlled trial', EUR J CARDIO-THORAC, vol. 50, no. 4, pp. 713-720. https://doi.org/10.1093/ejcts/ezw042

APA

Borger, M. A., Dohmen, P. M., Knosalla, C., Hammerschmidt, R., Merk, D. R., Richter, M., Doenst, T., Conradi, L., Treede, H., Moustafine, V., Holzhey, D. M., Duhay, F., & Strauch, J. (2016). Haemodynamic benefits of rapid deployment aortic valve replacement via a minimally invasive approach: 1-year results of a prospective multicentre randomized controlled trial. EUR J CARDIO-THORAC, 50(4), 713-720. https://doi.org/10.1093/ejcts/ezw042

Vancouver

Bibtex

@article{dd180a65ef9d41bd9946e7275cdfd572,
title = "Haemodynamic benefits of rapid deployment aortic valve replacement via a minimally invasive approach: 1-year results of a prospective multicentre randomized controlled trial",
abstract = "OBJECTIVES: Aortic valve replacement (AVR) via minimally invasive surgery (MIS) may provide clinical benefits in patients with aortic valve disease. A new class of bioprosthetic valves that enable rapid deployment AVR (RDAVR) may facilitate MIS. We here report the 1-year results of a randomized, multicentre trial comparing the outcomes for MIS-RDAVR with those for conventional AVR via full sternotomy (FS) with a commercially available stented aortic bioprosthesis.METHODS: A total of 100 patients with aortic stenosis were enrolled in a prospective, multicentre, randomized comparison trial (CADENCE-MIS). Key exclusion criteria included AVR requiring concomitant procedures, ejection fraction of <25% and recent myocardial infarction or stroke. Patients were randomized to undergo MIS-RDAVR via upper hemisternotomy (EDWARDS INTUITY) or AVR via FS with a commercially available stented valve. Procedural, early and late clinical outcomes were assessed for both groups. Haemodynamic performance was evaluated by an echocardiography CoreLaboratory.RESULTS: Technical success was achieved in 94% of MIS-RDAVR patients. MIS-RDAVR was associated with significantly reduced cross-clamp times compared with FS (41.3 ± 20.3 vs 54.0 ± 20.3 min, P < 0.001). Clinical and functional outcomes were similar at 30 days and 1 year postoperatively for both groups. While both groups received a similarly sized implanted valve (22.9 ± 2.1 mm MIS-RDAVR vs 23.0 ± 2.1 mm FS-AVR; P = 0.91), MIS-RDAVR patients had significantly lower peak gradients 1 year postoperatively (16.9 ± 5.3 vs 21.9 ± 8.6 mmHg; P = 0.033) and a trend towards lower mean gradients (9.1 ± 2.9 vs 11.5 ± 4.3 mmHg; P = 0.082). In addition, MIS-RDAVR patients had a significantly larger effective orifice area 1 year postoperatively (1.9 ± 0.5 vs 1.7 ± 0.4 cm2; P = 0.047). Paravalvular leaks, however, were significantly more common in the MIS-RDAVR group (P = 0.027).CONCLUSIONS: MIS-RDAVR is associated with a significantly reduced cross-clamp time and better valvular haemodynamic function than FS-AVR. However, paravalvular leak rates are higher with MIS-RDAVR.",
keywords = "Aged, Aortic Valve Stenosis/surgery, Bioprosthesis, Female, Heart Valve Prosthesis, Heart Valve Prosthesis Implantation/instrumentation, Hemodynamics, Humans, Male, Minimally Invasive Surgical Procedures/methods, Prospective Studies",
author = "Borger, {Michael A} and Dohmen, {Pascal M} and Christoph Knosalla and Robert Hammerschmidt and Merk, {Denis R} and Markus Richter and Torsten Doenst and Lenard Conradi and Hendrik Treede and Vadim Moustafine and Holzhey, {David M} and Francis Duhay and Justus Strauch",
note = "{\textcopyright} The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.",
year = "2016",
month = oct,
doi = "10.1093/ejcts/ezw042",
language = "English",
volume = "50",
pages = "713--720",
journal = "EUR J CARDIO-THORAC",
issn = "1010-7940",
publisher = "Elsevier",
number = "4",

}

RIS

TY - JOUR

T1 - Haemodynamic benefits of rapid deployment aortic valve replacement via a minimally invasive approach: 1-year results of a prospective multicentre randomized controlled trial

AU - Borger, Michael A

AU - Dohmen, Pascal M

AU - Knosalla, Christoph

AU - Hammerschmidt, Robert

AU - Merk, Denis R

AU - Richter, Markus

AU - Doenst, Torsten

AU - Conradi, Lenard

AU - Treede, Hendrik

AU - Moustafine, Vadim

AU - Holzhey, David M

AU - Duhay, Francis

AU - Strauch, Justus

N1 - © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

PY - 2016/10

Y1 - 2016/10

N2 - OBJECTIVES: Aortic valve replacement (AVR) via minimally invasive surgery (MIS) may provide clinical benefits in patients with aortic valve disease. A new class of bioprosthetic valves that enable rapid deployment AVR (RDAVR) may facilitate MIS. We here report the 1-year results of a randomized, multicentre trial comparing the outcomes for MIS-RDAVR with those for conventional AVR via full sternotomy (FS) with a commercially available stented aortic bioprosthesis.METHODS: A total of 100 patients with aortic stenosis were enrolled in a prospective, multicentre, randomized comparison trial (CADENCE-MIS). Key exclusion criteria included AVR requiring concomitant procedures, ejection fraction of <25% and recent myocardial infarction or stroke. Patients were randomized to undergo MIS-RDAVR via upper hemisternotomy (EDWARDS INTUITY) or AVR via FS with a commercially available stented valve. Procedural, early and late clinical outcomes were assessed for both groups. Haemodynamic performance was evaluated by an echocardiography CoreLaboratory.RESULTS: Technical success was achieved in 94% of MIS-RDAVR patients. MIS-RDAVR was associated with significantly reduced cross-clamp times compared with FS (41.3 ± 20.3 vs 54.0 ± 20.3 min, P < 0.001). Clinical and functional outcomes were similar at 30 days and 1 year postoperatively for both groups. While both groups received a similarly sized implanted valve (22.9 ± 2.1 mm MIS-RDAVR vs 23.0 ± 2.1 mm FS-AVR; P = 0.91), MIS-RDAVR patients had significantly lower peak gradients 1 year postoperatively (16.9 ± 5.3 vs 21.9 ± 8.6 mmHg; P = 0.033) and a trend towards lower mean gradients (9.1 ± 2.9 vs 11.5 ± 4.3 mmHg; P = 0.082). In addition, MIS-RDAVR patients had a significantly larger effective orifice area 1 year postoperatively (1.9 ± 0.5 vs 1.7 ± 0.4 cm2; P = 0.047). Paravalvular leaks, however, were significantly more common in the MIS-RDAVR group (P = 0.027).CONCLUSIONS: MIS-RDAVR is associated with a significantly reduced cross-clamp time and better valvular haemodynamic function than FS-AVR. However, paravalvular leak rates are higher with MIS-RDAVR.

AB - OBJECTIVES: Aortic valve replacement (AVR) via minimally invasive surgery (MIS) may provide clinical benefits in patients with aortic valve disease. A new class of bioprosthetic valves that enable rapid deployment AVR (RDAVR) may facilitate MIS. We here report the 1-year results of a randomized, multicentre trial comparing the outcomes for MIS-RDAVR with those for conventional AVR via full sternotomy (FS) with a commercially available stented aortic bioprosthesis.METHODS: A total of 100 patients with aortic stenosis were enrolled in a prospective, multicentre, randomized comparison trial (CADENCE-MIS). Key exclusion criteria included AVR requiring concomitant procedures, ejection fraction of <25% and recent myocardial infarction or stroke. Patients were randomized to undergo MIS-RDAVR via upper hemisternotomy (EDWARDS INTUITY) or AVR via FS with a commercially available stented valve. Procedural, early and late clinical outcomes were assessed for both groups. Haemodynamic performance was evaluated by an echocardiography CoreLaboratory.RESULTS: Technical success was achieved in 94% of MIS-RDAVR patients. MIS-RDAVR was associated with significantly reduced cross-clamp times compared with FS (41.3 ± 20.3 vs 54.0 ± 20.3 min, P < 0.001). Clinical and functional outcomes were similar at 30 days and 1 year postoperatively for both groups. While both groups received a similarly sized implanted valve (22.9 ± 2.1 mm MIS-RDAVR vs 23.0 ± 2.1 mm FS-AVR; P = 0.91), MIS-RDAVR patients had significantly lower peak gradients 1 year postoperatively (16.9 ± 5.3 vs 21.9 ± 8.6 mmHg; P = 0.033) and a trend towards lower mean gradients (9.1 ± 2.9 vs 11.5 ± 4.3 mmHg; P = 0.082). In addition, MIS-RDAVR patients had a significantly larger effective orifice area 1 year postoperatively (1.9 ± 0.5 vs 1.7 ± 0.4 cm2; P = 0.047). Paravalvular leaks, however, were significantly more common in the MIS-RDAVR group (P = 0.027).CONCLUSIONS: MIS-RDAVR is associated with a significantly reduced cross-clamp time and better valvular haemodynamic function than FS-AVR. However, paravalvular leak rates are higher with MIS-RDAVR.

KW - Aged

KW - Aortic Valve Stenosis/surgery

KW - Bioprosthesis

KW - Female

KW - Heart Valve Prosthesis

KW - Heart Valve Prosthesis Implantation/instrumentation

KW - Hemodynamics

KW - Humans

KW - Male

KW - Minimally Invasive Surgical Procedures/methods

KW - Prospective Studies

U2 - 10.1093/ejcts/ezw042

DO - 10.1093/ejcts/ezw042

M3 - SCORING: Journal article

C2 - 26935407

VL - 50

SP - 713

EP - 720

JO - EUR J CARDIO-THORAC

JF - EUR J CARDIO-THORAC

SN - 1010-7940

IS - 4

ER -