Abstract

BACKGROUND: Spinometry is a radiation-free method to three-dimensional spine imaging that provides additional information about the functional gait patterns related to the pelvis and lower extremities. This radiation-free technology uses the surface topography of the trunk to analyze surface asymmetry and identify bony landmarks, thereby aiding the assessment of spinal deformity and supporting long-term treatment regimes. Especially reliable dynamic spinometric data for spine and pelvis are necessary to evaluate the management of non-specific back pain.

RESEARCH AIM: This study aims to generate reliable dynamic spinometric data for spine and pelvis parameters that can serve as reference data for future studies and clinical practice.

METHODS: This study assessed 366 subjects (185 females) under static and 360 subjects (181 females) under dynamic (walking on a treadmill at 3 km/h and 5 km/h) conditions. The DIERS Formetric 4Dmotion® system uses stripes of light to detect the surface topography of the spine and pelvis and identifies specific landmarks to analyze the spine during standing and walking.

RESULTS: Relevant gender effects were calculated for lordotic angle (ηp2 = 0.22) and pelvic inclination (ηp2 = 0.26). Under static conditions, female subjects showed larger values for both parameters (lordotic angle: 41.6 ± 8.60°; pelvic inclination: 25.5 ± 7.49°). Regarding speed effects, three relevant changes were observed (sagittal imbalance: ηp2 = 0.74, kyphotic angle: ηp2 = 0.13, apical deviation: ηp2 = 0.11). The most considerable changes were observed between static condition and 3 km/h, especially for sagittal imbalance and lordotic angle. For these parameters, relevant effect sizes (d > 0.8) were calculated between static and 3 km/h for males and females. Concerning clinical vertebral parameters, only lordotic angle and pelvic inclination were correlated with each other (r = 0.722).

CONCLUSION: This study generated a gender-specific reference database of asymptomatic individuals for static and dynamic spinometry. It demonstrated that the DIERS Formetric 4Dmotion® system could capture natural changes in static and dynamic situations and catalogue functional adaptations of spino-pelvic statics at different speeds. The lordotic angle is an indirect marker of pelvic inclination, allowing spinometry to identify individuals at risk even under dynamic conditions.

Bibliographical data

Original languageEnglish
ISSN2405-8440
DOIs
Publication statusPublished - 15.04.2024

Comment Deanary

© 2024 The Authors.

PubMed 38633646