Evidence-based comparison of commercial interferon-gamma release assays for detecting active TB: a metaanalysis.

Standard

Evidence-based comparison of commercial interferon-gamma release assays for detecting active TB: a metaanalysis. / Diel, Roland; Loddenkemper, Robert; Nienhaus, Albert.

In: CHEST, Vol. 137, No. 4, 4, 2010, p. 952-968.

Research output: SCORING: Contribution to journalSCORING: Journal articleResearchpeer-review

Harvard

APA

Vancouver

Bibtex

@article{c199bb390d3b4e2092eefbccc39e7dfa,
title = "Evidence-based comparison of commercial interferon-gamma release assays for detecting active TB: a metaanalysis.",
abstract = "Test accuracy of interferon-gamma release assays (IGRAs) for diagnosing TB differs when using older or precommercial tools and inconsistent diagnostic criteria. This metaanalysis critically appraises studies investigating sensitivity and specificity of the commercial T-Spot.TB and the QuantiFERON-TB Gold In-Tube Assay (QFT-IT) among definitely confirmed TB cases. We searched Medline, EMBASE, and Cochrane bibliographies of relevant articles. Sensitivities, specificities, and indeterminate rates were pooled using a fixed effect model. Sensitivity of the tuberculin skin test (TST) was evaluated in the context of IGRA studies. In addition, the rates of indeterminates of both IGRAs were assessed. The pooled sensitivity of TST was 70% (95% CI, 0.67-0.72) compared with 81% (95% CI, 0.78-0.83) for the QFT-IT and 88% (95% CI, 0.85-0.90) for the T-Spot.TB. Sensitivity increased to 84% (95%CI, 0.81-0.87) and 89% (95% CI, 0.86-0.91) for the QFT-IT and T-Spot.TB, respectively, when restricted to performance in developed countries. In contrast, specificity of the QFT-IT was 99% (95% CI, 0.98-1.00) vs 86% for the T-Spot.TB (95% CI, 0.81-0.90). The pooled rate of indeterminate results was low, 2.1% (95% CI, 0.02-0.023) for the QFT-IT and 3.8% (95% CI, 0.035-0.042) for the T-Spot.TB, increasing to 4.4% (95% CI, 0.039-0.05) and 6.1% (95% CI, 0.052-0.071), respectively, among immunosuppressed hosts. The newest commercial IGRAs are superior, in comparison with the TST, for detecting confirmed active TB disease, especially when performed in developed countries.",
author = "Roland Diel and Robert Loddenkemper and Albert Nienhaus",
year = "2010",
language = "Deutsch",
volume = "137",
pages = "952--968",
journal = "CHEST",
issn = "0012-3692",
publisher = "American College of Chest Physicians",
number = "4",

}

RIS

TY - JOUR

T1 - Evidence-based comparison of commercial interferon-gamma release assays for detecting active TB: a metaanalysis.

AU - Diel, Roland

AU - Loddenkemper, Robert

AU - Nienhaus, Albert

PY - 2010

Y1 - 2010

N2 - Test accuracy of interferon-gamma release assays (IGRAs) for diagnosing TB differs when using older or precommercial tools and inconsistent diagnostic criteria. This metaanalysis critically appraises studies investigating sensitivity and specificity of the commercial T-Spot.TB and the QuantiFERON-TB Gold In-Tube Assay (QFT-IT) among definitely confirmed TB cases. We searched Medline, EMBASE, and Cochrane bibliographies of relevant articles. Sensitivities, specificities, and indeterminate rates were pooled using a fixed effect model. Sensitivity of the tuberculin skin test (TST) was evaluated in the context of IGRA studies. In addition, the rates of indeterminates of both IGRAs were assessed. The pooled sensitivity of TST was 70% (95% CI, 0.67-0.72) compared with 81% (95% CI, 0.78-0.83) for the QFT-IT and 88% (95% CI, 0.85-0.90) for the T-Spot.TB. Sensitivity increased to 84% (95%CI, 0.81-0.87) and 89% (95% CI, 0.86-0.91) for the QFT-IT and T-Spot.TB, respectively, when restricted to performance in developed countries. In contrast, specificity of the QFT-IT was 99% (95% CI, 0.98-1.00) vs 86% for the T-Spot.TB (95% CI, 0.81-0.90). The pooled rate of indeterminate results was low, 2.1% (95% CI, 0.02-0.023) for the QFT-IT and 3.8% (95% CI, 0.035-0.042) for the T-Spot.TB, increasing to 4.4% (95% CI, 0.039-0.05) and 6.1% (95% CI, 0.052-0.071), respectively, among immunosuppressed hosts. The newest commercial IGRAs are superior, in comparison with the TST, for detecting confirmed active TB disease, especially when performed in developed countries.

AB - Test accuracy of interferon-gamma release assays (IGRAs) for diagnosing TB differs when using older or precommercial tools and inconsistent diagnostic criteria. This metaanalysis critically appraises studies investigating sensitivity and specificity of the commercial T-Spot.TB and the QuantiFERON-TB Gold In-Tube Assay (QFT-IT) among definitely confirmed TB cases. We searched Medline, EMBASE, and Cochrane bibliographies of relevant articles. Sensitivities, specificities, and indeterminate rates were pooled using a fixed effect model. Sensitivity of the tuberculin skin test (TST) was evaluated in the context of IGRA studies. In addition, the rates of indeterminates of both IGRAs were assessed. The pooled sensitivity of TST was 70% (95% CI, 0.67-0.72) compared with 81% (95% CI, 0.78-0.83) for the QFT-IT and 88% (95% CI, 0.85-0.90) for the T-Spot.TB. Sensitivity increased to 84% (95%CI, 0.81-0.87) and 89% (95% CI, 0.86-0.91) for the QFT-IT and T-Spot.TB, respectively, when restricted to performance in developed countries. In contrast, specificity of the QFT-IT was 99% (95% CI, 0.98-1.00) vs 86% for the T-Spot.TB (95% CI, 0.81-0.90). The pooled rate of indeterminate results was low, 2.1% (95% CI, 0.02-0.023) for the QFT-IT and 3.8% (95% CI, 0.035-0.042) for the T-Spot.TB, increasing to 4.4% (95% CI, 0.039-0.05) and 6.1% (95% CI, 0.052-0.071), respectively, among immunosuppressed hosts. The newest commercial IGRAs are superior, in comparison with the TST, for detecting confirmed active TB disease, especially when performed in developed countries.

M3 - SCORING: Zeitschriftenaufsatz

VL - 137

SP - 952

EP - 968

JO - CHEST

JF - CHEST

SN - 0012-3692

IS - 4

M1 - 4

ER -