Effects of two instrument-generation changes on adenoma detection rate during screening colonoscopy: results from a prospective randomized comparative study

Standard

Effects of two instrument-generation changes on adenoma detection rate during screening colonoscopy: results from a prospective randomized comparative study. / Zimmermann-Fraedrich, Katharina; Groth, Stefan; Sehner, Susanne; Schubert, Stefan; Aschenbeck, Jens; Mayr, Michael; Aminalai, Alireza; Schröder, Andreas; Bruhn, Jens-Peter; Bläker, Michael; Rösch, Thomas; Schachschal, Guido.

In: ENDOSCOPY, Vol. 50, No. 9, 09.2018, p. 878-885.

Research output: SCORING: Contribution to journalSCORING: Journal articleResearchpeer-review

Harvard

APA

Vancouver

Bibtex

@article{4add34f227214dd2a49e803f485a6a8b,
title = "Effects of two instrument-generation changes on adenoma detection rate during screening colonoscopy: results from a prospective randomized comparative study",
abstract = "BACKGROUND:  Previous studies have shown that multiple colonoscope features have to be changed before an improvement in adenoma detection rate (ADR) becomes obvious, such as with changing from one instrument generation to the next but one. We wanted to evaluate whether such an effect can also be observed in a private-practice screening setting.METHODS:  In a randomized study, we compared the latest generation colonoscopes from one company (Olympus Exera III, 190) with the next to last one (Olympus 165), including only patients presenting for screening colonoscopy. The primary outcome was ADR achieved with 190 colonoscopes (190-C) in comparison with 165 colonoscopes (165-C).RESULTS:  1221 patients (46.1 % men; mean age 62.2 years, standard deviation 6.6) were included (599 screened with the Olympus Exera III, 190). The ADR difference in favor of the 190-C instrument (32 % [95 % confidence interval (CI) 26 % to 39 %] vs. 28 % [95 %CI 22 % to 34 %] in the 165-C group) failed to reach statistical significance (P = 0.10); only the rate of small (< 5 mm) adenomas was significantly increased at 22.5 % (95 %CI 19 % to 26 %) vs. 15.6 % (95 %CI 13 % to 18 %; P = 0.002). Furthermore, significantly more adenomas were found in the 190-C group, with an adenoma rate (all adenomas/all patients) of 0.57 (95 %CI 0.53 to 0.61) vs. 0.47 (95 %CI 0.43 to 0.51; P < 0.001).CONCLUSIONS:  This randomized comparative trial in a private-practice screening setting only partially confirmed the results of prior studies that, with multiple imaging improvements achieved over two instrument generations, an increase in overall adenoma number becomes measurable.",
keywords = "Clinical Trial",
author = "Katharina Zimmermann-Fraedrich and Stefan Groth and Susanne Sehner and Stefan Schubert and Jens Aschenbeck and Michael Mayr and Alireza Aminalai and Andreas Schr{\"o}der and Jens-Peter Bruhn and Michael Bl{\"a}ker and Thomas R{\"o}sch and Guido Schachschal",
note = "{\textcopyright} Georg Thieme Verlag KG Stuttgart · New York.",
year = "2018",
month = sep,
doi = "10.1055/a-0607-2636",
language = "English",
volume = "50",
pages = "878--885",
journal = "ENDOSCOPY",
issn = "0013-726X",
publisher = "Georg Thieme Verlag KG",
number = "9",

}

RIS

TY - JOUR

T1 - Effects of two instrument-generation changes on adenoma detection rate during screening colonoscopy: results from a prospective randomized comparative study

AU - Zimmermann-Fraedrich, Katharina

AU - Groth, Stefan

AU - Sehner, Susanne

AU - Schubert, Stefan

AU - Aschenbeck, Jens

AU - Mayr, Michael

AU - Aminalai, Alireza

AU - Schröder, Andreas

AU - Bruhn, Jens-Peter

AU - Bläker, Michael

AU - Rösch, Thomas

AU - Schachschal, Guido

N1 - © Georg Thieme Verlag KG Stuttgart · New York.

PY - 2018/9

Y1 - 2018/9

N2 - BACKGROUND:  Previous studies have shown that multiple colonoscope features have to be changed before an improvement in adenoma detection rate (ADR) becomes obvious, such as with changing from one instrument generation to the next but one. We wanted to evaluate whether such an effect can also be observed in a private-practice screening setting.METHODS:  In a randomized study, we compared the latest generation colonoscopes from one company (Olympus Exera III, 190) with the next to last one (Olympus 165), including only patients presenting for screening colonoscopy. The primary outcome was ADR achieved with 190 colonoscopes (190-C) in comparison with 165 colonoscopes (165-C).RESULTS:  1221 patients (46.1 % men; mean age 62.2 years, standard deviation 6.6) were included (599 screened with the Olympus Exera III, 190). The ADR difference in favor of the 190-C instrument (32 % [95 % confidence interval (CI) 26 % to 39 %] vs. 28 % [95 %CI 22 % to 34 %] in the 165-C group) failed to reach statistical significance (P = 0.10); only the rate of small (< 5 mm) adenomas was significantly increased at 22.5 % (95 %CI 19 % to 26 %) vs. 15.6 % (95 %CI 13 % to 18 %; P = 0.002). Furthermore, significantly more adenomas were found in the 190-C group, with an adenoma rate (all adenomas/all patients) of 0.57 (95 %CI 0.53 to 0.61) vs. 0.47 (95 %CI 0.43 to 0.51; P < 0.001).CONCLUSIONS:  This randomized comparative trial in a private-practice screening setting only partially confirmed the results of prior studies that, with multiple imaging improvements achieved over two instrument generations, an increase in overall adenoma number becomes measurable.

AB - BACKGROUND:  Previous studies have shown that multiple colonoscope features have to be changed before an improvement in adenoma detection rate (ADR) becomes obvious, such as with changing from one instrument generation to the next but one. We wanted to evaluate whether such an effect can also be observed in a private-practice screening setting.METHODS:  In a randomized study, we compared the latest generation colonoscopes from one company (Olympus Exera III, 190) with the next to last one (Olympus 165), including only patients presenting for screening colonoscopy. The primary outcome was ADR achieved with 190 colonoscopes (190-C) in comparison with 165 colonoscopes (165-C).RESULTS:  1221 patients (46.1 % men; mean age 62.2 years, standard deviation 6.6) were included (599 screened with the Olympus Exera III, 190). The ADR difference in favor of the 190-C instrument (32 % [95 % confidence interval (CI) 26 % to 39 %] vs. 28 % [95 %CI 22 % to 34 %] in the 165-C group) failed to reach statistical significance (P = 0.10); only the rate of small (< 5 mm) adenomas was significantly increased at 22.5 % (95 %CI 19 % to 26 %) vs. 15.6 % (95 %CI 13 % to 18 %; P = 0.002). Furthermore, significantly more adenomas were found in the 190-C group, with an adenoma rate (all adenomas/all patients) of 0.57 (95 %CI 0.53 to 0.61) vs. 0.47 (95 %CI 0.43 to 0.51; P < 0.001).CONCLUSIONS:  This randomized comparative trial in a private-practice screening setting only partially confirmed the results of prior studies that, with multiple imaging improvements achieved over two instrument generations, an increase in overall adenoma number becomes measurable.

KW - Clinical Trial

U2 - 10.1055/a-0607-2636

DO - 10.1055/a-0607-2636

M3 - SCORING: Journal article

C2 - 30036893

VL - 50

SP - 878

EP - 885

JO - ENDOSCOPY

JF - ENDOSCOPY

SN - 0013-726X

IS - 9

ER -