Doppler Ultrasound Triggering for Cardiovascular MRI at 3T in a Healthy Volunteer Study

Standard

Doppler Ultrasound Triggering for Cardiovascular MRI at 3T in a Healthy Volunteer Study. / Kording, Fabian; Yamamura, Jin; Lund, Gunnar; Ueberle, Friedrich; Jung, Caroline; Adam, Gerhard; Schoennagel, Bjoern Philip.

In: MAGN RESON MED, Vol. 16, No. 2, 10.04.2017, p. 98-108.

Research output: SCORING: Contribution to journalSCORING: Journal articleResearchpeer-review

Harvard

APA

Vancouver

Bibtex

@article{e1a23928cd174dce9630b098df46c9fe,
title = "Doppler Ultrasound Triggering for Cardiovascular MRI at 3T in a Healthy Volunteer Study",
abstract = "PURPOSE: Electrocardiogram (ECG) triggering for cardiac magnetic resonance (CMR) may be influenced by electromagnetic interferences with increasing magnetic field strength. The aim of this study was to evaluate the performance of Doppler ultrasound (DUS) as an alternative trigger technique for CMR in comparison to ECG and pulse oximetry (POX) at 3T and using different sequence types.METHODS: Balanced turbo field echo two-dimensional (2D) short axis cine CMR and 2D phase-contrast angiography of the ascending aorta was performed in 11 healthy volunteers at 3T using ECG, DUS, and POX for cardiac triggering. DUS and POX triggering were compared to the reference standard of ECG in terms of trigger quality (trigger detection and temporal variability), image quality [endocardial blurring (EB)], and functional measurements [left ventricular (LV) volumetry and aortic blood flow velocimetry].RESULTS: Trigger signal detection and temporal variability did not differ significantly between ECG/DUS (I = 0.6) and ECG/POX (P = 0.4). Averaged EB was similar for ECG, DUS, and POX (pECG/DUS = 0.4, pECG/POX = 0.9). Diastolic EB was significantly decreased for DUS in comparison to ECG (P = 0.02) and POX (P = 0.04). The LV function assessment and aortic blood flow were not significantly different.CONCLUSION: This study demonstrated the feasibility of DUS for gating human CMR at 3T. The magnetohydrodynamic effect did not significantly disturb ECG triggering in this small healthy volunteer study. DUS showed a significant improvement in diastolic EB but could not be identified as a superior trigger method. The potential benefit of DUS has to be evaluated in a larger clinical patient population.",
author = "Fabian Kording and Jin Yamamura and Gunnar Lund and Friedrich Ueberle and Caroline Jung and Gerhard Adam and Schoennagel, {Bjoern Philip}",
year = "2017",
month = apr,
day = "10",
doi = "10.2463/mrms.mp.2015-0104",
language = "English",
volume = "16",
pages = "98--108",
journal = "MAGN RESON MED",
issn = "0740-3194",
publisher = "John Wiley and Sons Inc.",
number = "2",

}

RIS

TY - JOUR

T1 - Doppler Ultrasound Triggering for Cardiovascular MRI at 3T in a Healthy Volunteer Study

AU - Kording, Fabian

AU - Yamamura, Jin

AU - Lund, Gunnar

AU - Ueberle, Friedrich

AU - Jung, Caroline

AU - Adam, Gerhard

AU - Schoennagel, Bjoern Philip

PY - 2017/4/10

Y1 - 2017/4/10

N2 - PURPOSE: Electrocardiogram (ECG) triggering for cardiac magnetic resonance (CMR) may be influenced by electromagnetic interferences with increasing magnetic field strength. The aim of this study was to evaluate the performance of Doppler ultrasound (DUS) as an alternative trigger technique for CMR in comparison to ECG and pulse oximetry (POX) at 3T and using different sequence types.METHODS: Balanced turbo field echo two-dimensional (2D) short axis cine CMR and 2D phase-contrast angiography of the ascending aorta was performed in 11 healthy volunteers at 3T using ECG, DUS, and POX for cardiac triggering. DUS and POX triggering were compared to the reference standard of ECG in terms of trigger quality (trigger detection and temporal variability), image quality [endocardial blurring (EB)], and functional measurements [left ventricular (LV) volumetry and aortic blood flow velocimetry].RESULTS: Trigger signal detection and temporal variability did not differ significantly between ECG/DUS (I = 0.6) and ECG/POX (P = 0.4). Averaged EB was similar for ECG, DUS, and POX (pECG/DUS = 0.4, pECG/POX = 0.9). Diastolic EB was significantly decreased for DUS in comparison to ECG (P = 0.02) and POX (P = 0.04). The LV function assessment and aortic blood flow were not significantly different.CONCLUSION: This study demonstrated the feasibility of DUS for gating human CMR at 3T. The magnetohydrodynamic effect did not significantly disturb ECG triggering in this small healthy volunteer study. DUS showed a significant improvement in diastolic EB but could not be identified as a superior trigger method. The potential benefit of DUS has to be evaluated in a larger clinical patient population.

AB - PURPOSE: Electrocardiogram (ECG) triggering for cardiac magnetic resonance (CMR) may be influenced by electromagnetic interferences with increasing magnetic field strength. The aim of this study was to evaluate the performance of Doppler ultrasound (DUS) as an alternative trigger technique for CMR in comparison to ECG and pulse oximetry (POX) at 3T and using different sequence types.METHODS: Balanced turbo field echo two-dimensional (2D) short axis cine CMR and 2D phase-contrast angiography of the ascending aorta was performed in 11 healthy volunteers at 3T using ECG, DUS, and POX for cardiac triggering. DUS and POX triggering were compared to the reference standard of ECG in terms of trigger quality (trigger detection and temporal variability), image quality [endocardial blurring (EB)], and functional measurements [left ventricular (LV) volumetry and aortic blood flow velocimetry].RESULTS: Trigger signal detection and temporal variability did not differ significantly between ECG/DUS (I = 0.6) and ECG/POX (P = 0.4). Averaged EB was similar for ECG, DUS, and POX (pECG/DUS = 0.4, pECG/POX = 0.9). Diastolic EB was significantly decreased for DUS in comparison to ECG (P = 0.02) and POX (P = 0.04). The LV function assessment and aortic blood flow were not significantly different.CONCLUSION: This study demonstrated the feasibility of DUS for gating human CMR at 3T. The magnetohydrodynamic effect did not significantly disturb ECG triggering in this small healthy volunteer study. DUS showed a significant improvement in diastolic EB but could not be identified as a superior trigger method. The potential benefit of DUS has to be evaluated in a larger clinical patient population.

U2 - 10.2463/mrms.mp.2015-0104

DO - 10.2463/mrms.mp.2015-0104

M3 - SCORING: Journal article

C2 - 27001390

VL - 16

SP - 98

EP - 108

JO - MAGN RESON MED

JF - MAGN RESON MED

SN - 0740-3194

IS - 2

ER -