Designs of colonoscopic adenoma detection trials: more positive results with tandem than with parallel studies - an analysis of studies on imaging techniques and mechanical devices

Standard

Designs of colonoscopic adenoma detection trials: more positive results with tandem than with parallel studies - an analysis of studies on imaging techniques and mechanical devices. / Zimmermann-Fraedrich, Katharina; Pohl, Heiko; Rösch, Thomas; Rex, Douglas K; Hassan, Cesare; Dekker, Evelien; Kaminski, Michal Filip; Bretthauer, Michael; de Heer, Jocelyn; Werner, Yuki; Schachschal, Guido; Groth, Stefan.

In: GUT, Vol. 70, No. 2, 02.2021, p. 268-275.

Research output: SCORING: Contribution to journalSCORING: Journal articleResearchpeer-review

Harvard

APA

Vancouver

Bibtex

@article{c68d522ef8bc4eb6bb01130c16d3ef2a,
title = "Designs of colonoscopic adenoma detection trials: more positive results with tandem than with parallel studies - an analysis of studies on imaging techniques and mechanical devices",
abstract = "BACKGROUND AND AIMS: Adenoma detection rate (ADR) has been shown to correlate with interval cancers after screening colonoscopy and is commonly used as surrogate parameter for its outcome quality. ADR improvements by various techniques have been studied in randomised trials using either parallel or tandem methodololgy.METHODS: A systematic literature search was done on randomised trials (full papers, English language) on tandem or parallel studies using either adenoma miss rates (AMR) or ADR as main outcome to test different novel technologies on imaging (new endoscope generation, narrow band imaging, iScan, Fujinon intelligent chromoendoscopy/blue laser imaging and wide angle scopes) and mechanical devices (transparent caps, endocuff, endorings and balloons). Available meta analyses were also screened for randomised studies.RESULTS: Overall, 24 randomised tandem trials with AMR (variable definitions and methodology) and 42 parallel studies using ADR (homogeneous methodology) as primary outcome were included. Significant differences in favour of the new method were found in 66.7% of tandem studies (8222 patients) but in only 23.8% of parallel studies (28 059 patients), with higher rates of positive studies for mechanical devices than for imaging methods. In a random-effects model, small absolute risk differences were found, but these were double in magnitude for tandem as compared with parallel studies (imaging: tandem 0.04 (0.01, 0.07), parallel 0.02 (0.00, 0.04); mechanical devices: tandem 0.08 (0.00, 0.15), parallel 0.04 (0.01, 0.07)). Nevertheless, 94.2% of missed adenomas in the tandem studies were small (<1 cm) and/or non-advanced.CONCLUSIONS: A tandem study is more likely to yield positive results than a simple parallel trial; this may be due to the use of different parameters, variable definitions and methodology, and perhaps also a higher likelihood of bias. Therefore, we suggest to accept positive results of tandem studies only if accompanied by positive results from parallel trials.",
author = "Katharina Zimmermann-Fraedrich and Heiko Pohl and Thomas R{\"o}sch and Rex, {Douglas K} and Cesare Hassan and Evelien Dekker and Kaminski, {Michal Filip} and Michael Bretthauer and {de Heer}, Jocelyn and Yuki Werner and Guido Schachschal and Stefan Groth",
note = "{\textcopyright} Author(s) (or their employer(s)) 2021. No commercial re-use. See rights and permissions. Published by BMJ.",
year = "2021",
month = feb,
doi = "10.1136/gutjnl-2020-320984",
language = "English",
volume = "70",
pages = "268--275",
journal = "GUT",
issn = "0017-5749",
publisher = "BMJ PUBLISHING GROUP",
number = "2",

}

RIS

TY - JOUR

T1 - Designs of colonoscopic adenoma detection trials: more positive results with tandem than with parallel studies - an analysis of studies on imaging techniques and mechanical devices

AU - Zimmermann-Fraedrich, Katharina

AU - Pohl, Heiko

AU - Rösch, Thomas

AU - Rex, Douglas K

AU - Hassan, Cesare

AU - Dekker, Evelien

AU - Kaminski, Michal Filip

AU - Bretthauer, Michael

AU - de Heer, Jocelyn

AU - Werner, Yuki

AU - Schachschal, Guido

AU - Groth, Stefan

N1 - © Author(s) (or their employer(s)) 2021. No commercial re-use. See rights and permissions. Published by BMJ.

PY - 2021/2

Y1 - 2021/2

N2 - BACKGROUND AND AIMS: Adenoma detection rate (ADR) has been shown to correlate with interval cancers after screening colonoscopy and is commonly used as surrogate parameter for its outcome quality. ADR improvements by various techniques have been studied in randomised trials using either parallel or tandem methodololgy.METHODS: A systematic literature search was done on randomised trials (full papers, English language) on tandem or parallel studies using either adenoma miss rates (AMR) or ADR as main outcome to test different novel technologies on imaging (new endoscope generation, narrow band imaging, iScan, Fujinon intelligent chromoendoscopy/blue laser imaging and wide angle scopes) and mechanical devices (transparent caps, endocuff, endorings and balloons). Available meta analyses were also screened for randomised studies.RESULTS: Overall, 24 randomised tandem trials with AMR (variable definitions and methodology) and 42 parallel studies using ADR (homogeneous methodology) as primary outcome were included. Significant differences in favour of the new method were found in 66.7% of tandem studies (8222 patients) but in only 23.8% of parallel studies (28 059 patients), with higher rates of positive studies for mechanical devices than for imaging methods. In a random-effects model, small absolute risk differences were found, but these were double in magnitude for tandem as compared with parallel studies (imaging: tandem 0.04 (0.01, 0.07), parallel 0.02 (0.00, 0.04); mechanical devices: tandem 0.08 (0.00, 0.15), parallel 0.04 (0.01, 0.07)). Nevertheless, 94.2% of missed adenomas in the tandem studies were small (<1 cm) and/or non-advanced.CONCLUSIONS: A tandem study is more likely to yield positive results than a simple parallel trial; this may be due to the use of different parameters, variable definitions and methodology, and perhaps also a higher likelihood of bias. Therefore, we suggest to accept positive results of tandem studies only if accompanied by positive results from parallel trials.

AB - BACKGROUND AND AIMS: Adenoma detection rate (ADR) has been shown to correlate with interval cancers after screening colonoscopy and is commonly used as surrogate parameter for its outcome quality. ADR improvements by various techniques have been studied in randomised trials using either parallel or tandem methodololgy.METHODS: A systematic literature search was done on randomised trials (full papers, English language) on tandem or parallel studies using either adenoma miss rates (AMR) or ADR as main outcome to test different novel technologies on imaging (new endoscope generation, narrow band imaging, iScan, Fujinon intelligent chromoendoscopy/blue laser imaging and wide angle scopes) and mechanical devices (transparent caps, endocuff, endorings and balloons). Available meta analyses were also screened for randomised studies.RESULTS: Overall, 24 randomised tandem trials with AMR (variable definitions and methodology) and 42 parallel studies using ADR (homogeneous methodology) as primary outcome were included. Significant differences in favour of the new method were found in 66.7% of tandem studies (8222 patients) but in only 23.8% of parallel studies (28 059 patients), with higher rates of positive studies for mechanical devices than for imaging methods. In a random-effects model, small absolute risk differences were found, but these were double in magnitude for tandem as compared with parallel studies (imaging: tandem 0.04 (0.01, 0.07), parallel 0.02 (0.00, 0.04); mechanical devices: tandem 0.08 (0.00, 0.15), parallel 0.04 (0.01, 0.07)). Nevertheless, 94.2% of missed adenomas in the tandem studies were small (<1 cm) and/or non-advanced.CONCLUSIONS: A tandem study is more likely to yield positive results than a simple parallel trial; this may be due to the use of different parameters, variable definitions and methodology, and perhaps also a higher likelihood of bias. Therefore, we suggest to accept positive results of tandem studies only if accompanied by positive results from parallel trials.

U2 - 10.1136/gutjnl-2020-320984

DO - 10.1136/gutjnl-2020-320984

M3 - SCORING: Journal article

C2 - 32409588

VL - 70

SP - 268

EP - 275

JO - GUT

JF - GUT

SN - 0017-5749

IS - 2