Current CT practice in Germany: Results and implications of a nationwide survey

Standard

Current CT practice in Germany: Results and implications of a nationwide survey. / Schegerer, Alexander A; Nagel, Hans-Dieter; Stamm, Georg; Adam, Gerhard; Brix, Gunnar.

In: EUR J RADIOL, Vol. 90, 05.2017, p. 114-128.

Research output: SCORING: Contribution to journalSCORING: Journal articleResearchpeer-review

Harvard

APA

Vancouver

Bibtex

@article{f71a18591b1b4b0d9adf3b45b64458c1,
title = "Current CT practice in Germany: Results and implications of a nationwide survey",
abstract = "PURPOSE: To assess patient doses and relative frequencies of standard CT examinations performed in Germany in 2013/14 as well as the effect of modern CT technology on patient exposure.METHODS: All known CT facilities in Germany were requested to complete a questionnaire on the frequency of 34 examinations and the respective parameter settings used. Taking into account type-specific properties of each scanner, effective doses were estimated for each reported examination. The mean and the percentiles of the CT dose index, scan length, dose length product, and effective dose were determined for each type of examination.RESULTS: According to the data provided for about 11% of all medical CT scanners operated in 2013/14, the effective dose was 4.6/5.9mSv per scan/examination. The effective dose was significantly reduced by about 15% compared to the CT practice before 2010. Modern CT technology, such as tube current modulation and iterative image reconstruction reduced the effective dose significantly by 6% and 13%, respectively. The mean effective dose applied at scanners produced by different manufacturers differed by 25%, at maximum.CONCLUSION: Patient exposure was reduced substantially in recent years. There is, however, still a considerable potential for further dose reduction by adapting scan protocols to the medical purpose and by a consequent exploitation of modern CT technologies.",
keywords = "Journal Article",
author = "Schegerer, {Alexander A} and Hans-Dieter Nagel and Georg Stamm and Gerhard Adam and Gunnar Brix",
note = "Copyright {\textcopyright} 2017 Elsevier B.V. All rights reserved.",
year = "2017",
month = may,
doi = "10.1016/j.ejrad.2017.02.021",
language = "English",
volume = "90",
pages = "114--128",
journal = "EUR J RADIOL",
issn = "0720-048X",
publisher = "Elsevier",

}

RIS

TY - JOUR

T1 - Current CT practice in Germany: Results and implications of a nationwide survey

AU - Schegerer, Alexander A

AU - Nagel, Hans-Dieter

AU - Stamm, Georg

AU - Adam, Gerhard

AU - Brix, Gunnar

N1 - Copyright © 2017 Elsevier B.V. All rights reserved.

PY - 2017/5

Y1 - 2017/5

N2 - PURPOSE: To assess patient doses and relative frequencies of standard CT examinations performed in Germany in 2013/14 as well as the effect of modern CT technology on patient exposure.METHODS: All known CT facilities in Germany were requested to complete a questionnaire on the frequency of 34 examinations and the respective parameter settings used. Taking into account type-specific properties of each scanner, effective doses were estimated for each reported examination. The mean and the percentiles of the CT dose index, scan length, dose length product, and effective dose were determined for each type of examination.RESULTS: According to the data provided for about 11% of all medical CT scanners operated in 2013/14, the effective dose was 4.6/5.9mSv per scan/examination. The effective dose was significantly reduced by about 15% compared to the CT practice before 2010. Modern CT technology, such as tube current modulation and iterative image reconstruction reduced the effective dose significantly by 6% and 13%, respectively. The mean effective dose applied at scanners produced by different manufacturers differed by 25%, at maximum.CONCLUSION: Patient exposure was reduced substantially in recent years. There is, however, still a considerable potential for further dose reduction by adapting scan protocols to the medical purpose and by a consequent exploitation of modern CT technologies.

AB - PURPOSE: To assess patient doses and relative frequencies of standard CT examinations performed in Germany in 2013/14 as well as the effect of modern CT technology on patient exposure.METHODS: All known CT facilities in Germany were requested to complete a questionnaire on the frequency of 34 examinations and the respective parameter settings used. Taking into account type-specific properties of each scanner, effective doses were estimated for each reported examination. The mean and the percentiles of the CT dose index, scan length, dose length product, and effective dose were determined for each type of examination.RESULTS: According to the data provided for about 11% of all medical CT scanners operated in 2013/14, the effective dose was 4.6/5.9mSv per scan/examination. The effective dose was significantly reduced by about 15% compared to the CT practice before 2010. Modern CT technology, such as tube current modulation and iterative image reconstruction reduced the effective dose significantly by 6% and 13%, respectively. The mean effective dose applied at scanners produced by different manufacturers differed by 25%, at maximum.CONCLUSION: Patient exposure was reduced substantially in recent years. There is, however, still a considerable potential for further dose reduction by adapting scan protocols to the medical purpose and by a consequent exploitation of modern CT technologies.

KW - Journal Article

U2 - 10.1016/j.ejrad.2017.02.021

DO - 10.1016/j.ejrad.2017.02.021

M3 - SCORING: Journal article

C2 - 28583622

VL - 90

SP - 114

EP - 128

JO - EUR J RADIOL

JF - EUR J RADIOL

SN - 0720-048X

ER -