Condylar position analysis with a new electronic condylar position measuring instrument E-CPM: influence of different examiners and a working bite on reproducibility.

Standard

Condylar position analysis with a new electronic condylar position measuring instrument E-CPM: influence of different examiners and a working bite on reproducibility. / Vahle-Hinz, K; Rybczynski, A; Jakstat, H; Ahlers, Oliver.

In: INT J COMPUT DENT, Vol. 12, No. 3, 3, 2009, p. 235-246.

Research output: SCORING: Contribution to journalSCORING: Journal articleResearchpeer-review

Harvard

APA

Vancouver

Bibtex

@article{3b8dfacef3464aa5a6a18f0fbc5955b4,
title = "Condylar position analysis with a new electronic condylar position measuring instrument E-CPM: influence of different examiners and a working bite on reproducibility.",
abstract = "Condylar position analysis facilitates a quantitative comparison of the condylar position with and without a bite record, different records and changed influencing factors. Handling by the examiner when positioning the model is a significant factor with regard to the accuracy of the examination. Measurement accuracy could be improved when positioning the models by using special working bites, hence the objective of the experiments described in this study consisted in examining the extent to which the measuring results are influenced by different examiners and by using working bites.",
author = "K Vahle-Hinz and A Rybczynski and H Jakstat and Oliver Ahlers",
year = "2009",
language = "Deutsch",
volume = "12",
pages = "235--246",
journal = "INT J COMPUT DENT",
issn = "1463-4201",
publisher = "Quintessenz Verlags-GmbH",
number = "3",

}

RIS

TY - JOUR

T1 - Condylar position analysis with a new electronic condylar position measuring instrument E-CPM: influence of different examiners and a working bite on reproducibility.

AU - Vahle-Hinz, K

AU - Rybczynski, A

AU - Jakstat, H

AU - Ahlers, Oliver

PY - 2009

Y1 - 2009

N2 - Condylar position analysis facilitates a quantitative comparison of the condylar position with and without a bite record, different records and changed influencing factors. Handling by the examiner when positioning the model is a significant factor with regard to the accuracy of the examination. Measurement accuracy could be improved when positioning the models by using special working bites, hence the objective of the experiments described in this study consisted in examining the extent to which the measuring results are influenced by different examiners and by using working bites.

AB - Condylar position analysis facilitates a quantitative comparison of the condylar position with and without a bite record, different records and changed influencing factors. Handling by the examiner when positioning the model is a significant factor with regard to the accuracy of the examination. Measurement accuracy could be improved when positioning the models by using special working bites, hence the objective of the experiments described in this study consisted in examining the extent to which the measuring results are influenced by different examiners and by using working bites.