Concomitant surgical atrial fibrillation ablation and event recorder implantation: better monitoring, better outcome?

Standard

Concomitant surgical atrial fibrillation ablation and event recorder implantation: better monitoring, better outcome? / Pecha, Simon; Schäfer, Timm; Hartel, Friederike; Ahmadzade, Teymour; Subbotina, Irina; Reichenspurner, Hermann; Wagner, Florian Matthias.

In: INTERACT CARDIOV TH, Vol. 16, No. 4, 04.2013, p. 465-469.

Research output: SCORING: Contribution to journalSCORING: Journal articleResearchpeer-review

Harvard

APA

Vancouver

Bibtex

@article{8b58ccb1b750451a98cf72e057e0c075,
title = "Concomitant surgical atrial fibrillation ablation and event recorder implantation: better monitoring, better outcome?",
abstract = "OBJECTIVES: Concomitant ablation is an established therapy in cardiac surgical patients with atrial fibrillation (AF). Post-discharge care seems to be an essential factor for clinical outcome. We analysed the influence of event recorder (ER) implantation and therapy guidance by the results of continuous rhythm monitoring of consecutive postoperative follow-up by our department of electrophysiology.METHODS: Between July 2003 and August 2010, 401 cardiac surgical patients underwent concomitant surgical AF ablation therapy. Since August 2009, an ER (REVEAL XT, Medtronic, Inc., Minneapolis, MN, USA) was implanted in 98 patients intraoperatively. ER interrogation was performed by our department of electrophysiology 3, 6 and 12 months postoperatively. Results and outcomes were compared with a matched cohort of patients with ablation and no ER implantation. In those patients, rhythm follow-up was obtained by 24-h Holter ECG. Primary end-point of the study was sinus rhythm rate after 12 months.RESULTS: Mean patient's age was 67.0 ± 9.7 years, and 68.4% were male. No major ablation-related complications occurred. The overall sinus rhythm rate was 65.3% after 1-year follow-up. The sinus rhythm rate off antiarrhythmic drugs was 60.3%. The conversion rate tended to be higher in patients with an implanted ER (69.3 vs 60.1%, respectively; P = 0.098). Also, the sinus rhythm rate of anti-arrhythmic drugs was higher in the ER group (64.3 vs 56.2). Patients with ER were seen more often by a cardiologist in the first postoperative year (3.1 ± 0.8 vs 1.5 ± 0.9; P < 0.05) and received significantly more additional procedures, like electrical cardioversion or additional catheter-based ablation (16.1 vs 4.3%; P < 0.001; 11.2 vs 3.1%; P < 0.001).CONCLUSIONS: Implantation of an ER with link-up to a cardiology and/or electrophysiology provides optimized anti-arrhythmic drug management and higher rates of consecutive procedures like cardioversion or additional catheter-based ablation. As a result, a trend to higher sinus rhythm conversion rate was observed after 1-year follow-up.",
keywords = "Aged, Anti-Arrhythmia Agents/therapeutic use, Atrial Fibrillation/diagnosis, Catheter Ablation/adverse effects, Chi-Square Distribution, Electrocardiography, Ambulatory, Equipment Design, Female, Humans, Logistic Models, Male, Middle Aged, Multivariate Analysis, Predictive Value of Tests, Recurrence, Retrospective Studies, Signal Processing, Computer-Assisted, Telemetry/methods, Time Factors, Treatment Outcome",
author = "Simon Pecha and Timm Sch{\"a}fer and Friederike Hartel and Teymour Ahmadzade and Irina Subbotina and Hermann Reichenspurner and Wagner, {Florian Matthias}",
year = "2013",
month = apr,
doi = "10.1093/icvts/ivs564",
language = "English",
volume = "16",
pages = "465--469",
journal = "INTERACT CARDIOV TH",
issn = "1569-9293",
publisher = "European Association for Cardio-Thoracic Surgery",
number = "4",

}

RIS

TY - JOUR

T1 - Concomitant surgical atrial fibrillation ablation and event recorder implantation: better monitoring, better outcome?

AU - Pecha, Simon

AU - Schäfer, Timm

AU - Hartel, Friederike

AU - Ahmadzade, Teymour

AU - Subbotina, Irina

AU - Reichenspurner, Hermann

AU - Wagner, Florian Matthias

PY - 2013/4

Y1 - 2013/4

N2 - OBJECTIVES: Concomitant ablation is an established therapy in cardiac surgical patients with atrial fibrillation (AF). Post-discharge care seems to be an essential factor for clinical outcome. We analysed the influence of event recorder (ER) implantation and therapy guidance by the results of continuous rhythm monitoring of consecutive postoperative follow-up by our department of electrophysiology.METHODS: Between July 2003 and August 2010, 401 cardiac surgical patients underwent concomitant surgical AF ablation therapy. Since August 2009, an ER (REVEAL XT, Medtronic, Inc., Minneapolis, MN, USA) was implanted in 98 patients intraoperatively. ER interrogation was performed by our department of electrophysiology 3, 6 and 12 months postoperatively. Results and outcomes were compared with a matched cohort of patients with ablation and no ER implantation. In those patients, rhythm follow-up was obtained by 24-h Holter ECG. Primary end-point of the study was sinus rhythm rate after 12 months.RESULTS: Mean patient's age was 67.0 ± 9.7 years, and 68.4% were male. No major ablation-related complications occurred. The overall sinus rhythm rate was 65.3% after 1-year follow-up. The sinus rhythm rate off antiarrhythmic drugs was 60.3%. The conversion rate tended to be higher in patients with an implanted ER (69.3 vs 60.1%, respectively; P = 0.098). Also, the sinus rhythm rate of anti-arrhythmic drugs was higher in the ER group (64.3 vs 56.2). Patients with ER were seen more often by a cardiologist in the first postoperative year (3.1 ± 0.8 vs 1.5 ± 0.9; P < 0.05) and received significantly more additional procedures, like electrical cardioversion or additional catheter-based ablation (16.1 vs 4.3%; P < 0.001; 11.2 vs 3.1%; P < 0.001).CONCLUSIONS: Implantation of an ER with link-up to a cardiology and/or electrophysiology provides optimized anti-arrhythmic drug management and higher rates of consecutive procedures like cardioversion or additional catheter-based ablation. As a result, a trend to higher sinus rhythm conversion rate was observed after 1-year follow-up.

AB - OBJECTIVES: Concomitant ablation is an established therapy in cardiac surgical patients with atrial fibrillation (AF). Post-discharge care seems to be an essential factor for clinical outcome. We analysed the influence of event recorder (ER) implantation and therapy guidance by the results of continuous rhythm monitoring of consecutive postoperative follow-up by our department of electrophysiology.METHODS: Between July 2003 and August 2010, 401 cardiac surgical patients underwent concomitant surgical AF ablation therapy. Since August 2009, an ER (REVEAL XT, Medtronic, Inc., Minneapolis, MN, USA) was implanted in 98 patients intraoperatively. ER interrogation was performed by our department of electrophysiology 3, 6 and 12 months postoperatively. Results and outcomes were compared with a matched cohort of patients with ablation and no ER implantation. In those patients, rhythm follow-up was obtained by 24-h Holter ECG. Primary end-point of the study was sinus rhythm rate after 12 months.RESULTS: Mean patient's age was 67.0 ± 9.7 years, and 68.4% were male. No major ablation-related complications occurred. The overall sinus rhythm rate was 65.3% after 1-year follow-up. The sinus rhythm rate off antiarrhythmic drugs was 60.3%. The conversion rate tended to be higher in patients with an implanted ER (69.3 vs 60.1%, respectively; P = 0.098). Also, the sinus rhythm rate of anti-arrhythmic drugs was higher in the ER group (64.3 vs 56.2). Patients with ER were seen more often by a cardiologist in the first postoperative year (3.1 ± 0.8 vs 1.5 ± 0.9; P < 0.05) and received significantly more additional procedures, like electrical cardioversion or additional catheter-based ablation (16.1 vs 4.3%; P < 0.001; 11.2 vs 3.1%; P < 0.001).CONCLUSIONS: Implantation of an ER with link-up to a cardiology and/or electrophysiology provides optimized anti-arrhythmic drug management and higher rates of consecutive procedures like cardioversion or additional catheter-based ablation. As a result, a trend to higher sinus rhythm conversion rate was observed after 1-year follow-up.

KW - Aged

KW - Anti-Arrhythmia Agents/therapeutic use

KW - Atrial Fibrillation/diagnosis

KW - Catheter Ablation/adverse effects

KW - Chi-Square Distribution

KW - Electrocardiography, Ambulatory

KW - Equipment Design

KW - Female

KW - Humans

KW - Logistic Models

KW - Male

KW - Middle Aged

KW - Multivariate Analysis

KW - Predictive Value of Tests

KW - Recurrence

KW - Retrospective Studies

KW - Signal Processing, Computer-Assisted

KW - Telemetry/methods

KW - Time Factors

KW - Treatment Outcome

U2 - 10.1093/icvts/ivs564

DO - 10.1093/icvts/ivs564

M3 - SCORING: Journal article

C2 - 23325063

VL - 16

SP - 465

EP - 469

JO - INTERACT CARDIOV TH

JF - INTERACT CARDIOV TH

SN - 1569-9293

IS - 4

ER -