Comprehensive ultrahigh resolution whole brain in vivo MRI dataset as a human phantom

Standard

Comprehensive ultrahigh resolution whole brain in vivo MRI dataset as a human phantom. / Lüsebrink, Falk; Mattern, Hendrik; Yakupov, Renat; Acosta-Cabronero, Julio; Ashtarayeh, Mohammad; Oeltze-Jafra, Steffen; Speck, Oliver.

In: SCI DATA, Vol. 8, No. 1, 25.05.2021, p. 138.

Research output: SCORING: Contribution to journalSCORING: Journal articleResearchpeer-review

Harvard

Lüsebrink, F, Mattern, H, Yakupov, R, Acosta-Cabronero, J, Ashtarayeh, M, Oeltze-Jafra, S & Speck, O 2021, 'Comprehensive ultrahigh resolution whole brain in vivo MRI dataset as a human phantom', SCI DATA, vol. 8, no. 1, pp. 138. https://doi.org/10.1038/s41597-021-00923-w

APA

Lüsebrink, F., Mattern, H., Yakupov, R., Acosta-Cabronero, J., Ashtarayeh, M., Oeltze-Jafra, S., & Speck, O. (2021). Comprehensive ultrahigh resolution whole brain in vivo MRI dataset as a human phantom. SCI DATA, 8(1), 138. https://doi.org/10.1038/s41597-021-00923-w

Vancouver

Lüsebrink F, Mattern H, Yakupov R, Acosta-Cabronero J, Ashtarayeh M, Oeltze-Jafra S et al. Comprehensive ultrahigh resolution whole brain in vivo MRI dataset as a human phantom. SCI DATA. 2021 May 25;8(1):138. https://doi.org/10.1038/s41597-021-00923-w

Bibtex

@article{0787dcdde6c846518431d9f2213dc45d,
title = "Comprehensive ultrahigh resolution whole brain in vivo MRI dataset as a human phantom",
abstract = "Here, we present an extension to our previously published structural ultrahigh resolution T1-weighted magnetic resonance imaging (MRI) dataset with an isotropic resolution of 250 µm, consisting of multiple additional ultrahigh resolution contrasts. Included are up to 150 µm Time-of-Flight angiography, an updated 250 µm structural T1-weighted reconstruction, 330 µm quantitative susceptibility mapping, up to 450 µm structural T2-weighted imaging, 700 µm T1-weighted back-to-back scans, 800 µm diffusion tensor imaging, one hour continuous resting-state functional MRI with an isotropic spatial resolution of 1.8 mm as well as more than 120 other structural T1-weighted volumes together with multiple corresponding proton density weighted acquisitions collected over ten years. All data are from the same participant and were acquired on the same 7 T scanner. The repository contains the unprocessed data as well as (pre-)processing results. The data were acquired in multiple studies with individual goals. This is a unique and comprehensive collection comprising a {"}human phantom{"} dataset. Therefore, we compiled, processed, and structured the data, making them publicly available for further investigation.",
author = "Falk L{\"u}sebrink and Hendrik Mattern and Renat Yakupov and Julio Acosta-Cabronero and Mohammad Ashtarayeh and Steffen Oeltze-Jafra and Oliver Speck",
year = "2021",
month = may,
day = "25",
doi = "10.1038/s41597-021-00923-w",
language = "English",
volume = "8",
pages = "138",
journal = "SCI DATA",
issn = "2052-4463",
publisher = "NATURE PUBLISHING GROUP",
number = "1",

}

RIS

TY - JOUR

T1 - Comprehensive ultrahigh resolution whole brain in vivo MRI dataset as a human phantom

AU - Lüsebrink, Falk

AU - Mattern, Hendrik

AU - Yakupov, Renat

AU - Acosta-Cabronero, Julio

AU - Ashtarayeh, Mohammad

AU - Oeltze-Jafra, Steffen

AU - Speck, Oliver

PY - 2021/5/25

Y1 - 2021/5/25

N2 - Here, we present an extension to our previously published structural ultrahigh resolution T1-weighted magnetic resonance imaging (MRI) dataset with an isotropic resolution of 250 µm, consisting of multiple additional ultrahigh resolution contrasts. Included are up to 150 µm Time-of-Flight angiography, an updated 250 µm structural T1-weighted reconstruction, 330 µm quantitative susceptibility mapping, up to 450 µm structural T2-weighted imaging, 700 µm T1-weighted back-to-back scans, 800 µm diffusion tensor imaging, one hour continuous resting-state functional MRI with an isotropic spatial resolution of 1.8 mm as well as more than 120 other structural T1-weighted volumes together with multiple corresponding proton density weighted acquisitions collected over ten years. All data are from the same participant and were acquired on the same 7 T scanner. The repository contains the unprocessed data as well as (pre-)processing results. The data were acquired in multiple studies with individual goals. This is a unique and comprehensive collection comprising a "human phantom" dataset. Therefore, we compiled, processed, and structured the data, making them publicly available for further investigation.

AB - Here, we present an extension to our previously published structural ultrahigh resolution T1-weighted magnetic resonance imaging (MRI) dataset with an isotropic resolution of 250 µm, consisting of multiple additional ultrahigh resolution contrasts. Included are up to 150 µm Time-of-Flight angiography, an updated 250 µm structural T1-weighted reconstruction, 330 µm quantitative susceptibility mapping, up to 450 µm structural T2-weighted imaging, 700 µm T1-weighted back-to-back scans, 800 µm diffusion tensor imaging, one hour continuous resting-state functional MRI with an isotropic spatial resolution of 1.8 mm as well as more than 120 other structural T1-weighted volumes together with multiple corresponding proton density weighted acquisitions collected over ten years. All data are from the same participant and were acquired on the same 7 T scanner. The repository contains the unprocessed data as well as (pre-)processing results. The data were acquired in multiple studies with individual goals. This is a unique and comprehensive collection comprising a "human phantom" dataset. Therefore, we compiled, processed, and structured the data, making them publicly available for further investigation.

U2 - 10.1038/s41597-021-00923-w

DO - 10.1038/s41597-021-00923-w

M3 - SCORING: Journal article

C2 - 34035308

VL - 8

SP - 138

JO - SCI DATA

JF - SCI DATA

SN - 2052-4463

IS - 1

ER -