Comparison of the CytoSorb® 300 mL and Jafron HA380 hemoadsorption devices: an in vitro study
Standard
Comparison of the CytoSorb® 300 mL and Jafron HA380 hemoadsorption devices: an in vitro study. / Nierhaus, Axel; Morales, Jesus; Wendt, Daniel; Scheier, Jörg; Gutzler, Dominik; Jarczak, Dominik; Born, Frank; Hagl, Christian; Deliargyris, Efthymios; Mehta, Yatin.
In: MINIM INVASIV THER, Vol. 31, No. 7, 10.2022, p. 1058-1065.Research output: SCORING: Contribution to journal › SCORING: Journal article › Research › peer-review
Harvard
APA
Vancouver
Bibtex
}
RIS
TY - JOUR
T1 - Comparison of the CytoSorb® 300 mL and Jafron HA380 hemoadsorption devices: an in vitro study
AU - Nierhaus, Axel
AU - Morales, Jesus
AU - Wendt, Daniel
AU - Scheier, Jörg
AU - Gutzler, Dominik
AU - Jarczak, Dominik
AU - Born, Frank
AU - Hagl, Christian
AU - Deliargyris, Efthymios
AU - Mehta, Yatin
PY - 2022/10
Y1 - 2022/10
N2 - INTRODUCTION: We performed an analysis of two blood purification systems to determine their performance for removing interleukins (ILs)-6 and 10, tumor necrosis factor (TNF)-α and monocyte chemoattractant protein (MCP)-1 from blood.MATERIAL AND METHODS: An in vitro hemoperfusion blood recirculation circuit was used to compare the CytoSorb® 300 mL (CytoSorbents Inc., Princeton, NJ) and Jafron HA 380 (Jafron Biomedical Co., Ltd., Zhuhai City, China) devices. The removal of purified recombinant human IL-6, IL-10, TNFα and MCP-1 by the adsorbers was compared at various timepoints. Three runs were completed and removal was evaluated as the mean area under the curve (AUC).RESULTS: Both devices showed effective removal of the tested cytokines. IL-6, IL-10, TNFα and MCP-1 were removed faster and to a higher extent by the CytoSorb® 300 mL device. At maximal time of 12 h, overall removal according to AUC of remaining concentrations was significantly lower with CytoSorb® 300 mL compared with HA 380 (IL-6: 1075.5 ± 665.9 vs. 4345.1 ± 1499.3 (p = 0.01), IL-10: 5065.7 ± 882.5 vs. 11,939.7 ± 4523.1 (p = 0.03), TNF-α: 6519.9 ± 997.6 vs. 10,303.7 ± 2347.0 (p = 0.03) and MCP-1: 278.9 ± 40.7 vs. 607.3 ± 84.4 (p = 0.001)).CONCLUSIONS: Both the CytoSorb® and the Jafron HA 380 devices are capable of removing cytokines from blood in a benchtop model. The CytoSorb® 300 device was significantly more efficient achieving the bulk of the removal in the first 120 min.
AB - INTRODUCTION: We performed an analysis of two blood purification systems to determine their performance for removing interleukins (ILs)-6 and 10, tumor necrosis factor (TNF)-α and monocyte chemoattractant protein (MCP)-1 from blood.MATERIAL AND METHODS: An in vitro hemoperfusion blood recirculation circuit was used to compare the CytoSorb® 300 mL (CytoSorbents Inc., Princeton, NJ) and Jafron HA 380 (Jafron Biomedical Co., Ltd., Zhuhai City, China) devices. The removal of purified recombinant human IL-6, IL-10, TNFα and MCP-1 by the adsorbers was compared at various timepoints. Three runs were completed and removal was evaluated as the mean area under the curve (AUC).RESULTS: Both devices showed effective removal of the tested cytokines. IL-6, IL-10, TNFα and MCP-1 were removed faster and to a higher extent by the CytoSorb® 300 mL device. At maximal time of 12 h, overall removal according to AUC of remaining concentrations was significantly lower with CytoSorb® 300 mL compared with HA 380 (IL-6: 1075.5 ± 665.9 vs. 4345.1 ± 1499.3 (p = 0.01), IL-10: 5065.7 ± 882.5 vs. 11,939.7 ± 4523.1 (p = 0.03), TNF-α: 6519.9 ± 997.6 vs. 10,303.7 ± 2347.0 (p = 0.03) and MCP-1: 278.9 ± 40.7 vs. 607.3 ± 84.4 (p = 0.001)).CONCLUSIONS: Both the CytoSorb® and the Jafron HA 380 devices are capable of removing cytokines from blood in a benchtop model. The CytoSorb® 300 device was significantly more efficient achieving the bulk of the removal in the first 120 min.
U2 - 10.1080/13645706.2022.2104617
DO - 10.1080/13645706.2022.2104617
M3 - SCORING: Journal article
C2 - 35913784
VL - 31
SP - 1058
EP - 1065
JO - MINIM INVASIV THER
JF - MINIM INVASIV THER
SN - 1364-5706
IS - 7
ER -