Comparative evaluation of the Datex-Ohmeda S/5 Entropy Module and the Bispectral Index monitor during propofol-remifentanil anesthesia.

Standard

Comparative evaluation of the Datex-Ohmeda S/5 Entropy Module and the Bispectral Index monitor during propofol-remifentanil anesthesia. / Schmidt, Gunter Niels; Bischoff, Petra; Standl, Thomas; Hellstern, Angelika; Teuber, Olaf; Jochen, Schulte Esch.

In: ANESTHESIOLOGY, Vol. 101, No. 6, 6, 2004, p. 1283-1290.

Research output: SCORING: Contribution to journalSCORING: Journal articleResearchpeer-review

Harvard

APA

Vancouver

Bibtex

@article{13941a591540465f9718e9b78335d841,
title = "Comparative evaluation of the Datex-Ohmeda S/5 Entropy Module and the Bispectral Index monitor during propofol-remifentanil anesthesia.",
abstract = "BACKGROUND: Different analytical concepts were introduced to quantify the changes of the electroencephalogram. The Datex-Ohmeda S/5 Entropy Module (Datex-Ohmeda Division, Instrumentarium Corp., Helsinki, Finland) was the first commercial monitor based on the entropy generating two indices, the state entropy (SE) and the response entropy (RE). The aim of the current study was to compare the accuracy of SE and RE with the Bispectral Index(R) monitor (BIS(R); Aspect Medical Systems, Newton, MA) during propofol-remifentanil anesthesia. METHODS: The authors investigated 20 female patients during minor gynecologic surgery. SE, RE, BIS, mean arterial blood pressure, heart rate, and sedation level were recorded every 20 s during stepwise increase (target-controlled infusion, 0.5 microg/ml) of propofol until the patients lost response. Five minutes after loss of response, remifentanil infusion (0.4 microg . kg(-1) . min(-1)) was started. Spearman correlation coefficient and prediction probability were calculated for sedation levels with SE, RE, BIS, mean arterial blood pressure, and heart rate. The ability of the investigated parameters to distinguish between the anesthesia steps awake versus loss of response, awake versus anesthesia, anesthesia versus first reaction, and anesthesia versus extubation was analyzed with the prediction probability. RESULTS: SE correlates best with sedation levels, but no significant differences of the prediction probability values among SE, RE, and BIS were found. The prediction probability for all investigated steps of anesthesia did not show significant differences among SE, RE, and BIS. SE, RE, and BIS were superior to mean arterial blood pressure and heart rate. CONCLUSION: SE, RE, and BIS revealed similar information about the level of sedation and allowed the authors to distinguish between different steps of anesthesia. Both monitors provided useful additional information for the anesthesiologist.",
author = "Schmidt, {Gunter Niels} and Petra Bischoff and Thomas Standl and Angelika Hellstern and Olaf Teuber and Jochen, {Schulte Esch}",
year = "2004",
language = "Deutsch",
volume = "101",
pages = "1283--1290",
journal = "ANESTHESIOLOGY",
issn = "0003-3022",
publisher = "Lippincott Williams and Wilkins",
number = "6",

}

RIS

TY - JOUR

T1 - Comparative evaluation of the Datex-Ohmeda S/5 Entropy Module and the Bispectral Index monitor during propofol-remifentanil anesthesia.

AU - Schmidt, Gunter Niels

AU - Bischoff, Petra

AU - Standl, Thomas

AU - Hellstern, Angelika

AU - Teuber, Olaf

AU - Jochen, Schulte Esch

PY - 2004

Y1 - 2004

N2 - BACKGROUND: Different analytical concepts were introduced to quantify the changes of the electroencephalogram. The Datex-Ohmeda S/5 Entropy Module (Datex-Ohmeda Division, Instrumentarium Corp., Helsinki, Finland) was the first commercial monitor based on the entropy generating two indices, the state entropy (SE) and the response entropy (RE). The aim of the current study was to compare the accuracy of SE and RE with the Bispectral Index(R) monitor (BIS(R); Aspect Medical Systems, Newton, MA) during propofol-remifentanil anesthesia. METHODS: The authors investigated 20 female patients during minor gynecologic surgery. SE, RE, BIS, mean arterial blood pressure, heart rate, and sedation level were recorded every 20 s during stepwise increase (target-controlled infusion, 0.5 microg/ml) of propofol until the patients lost response. Five minutes after loss of response, remifentanil infusion (0.4 microg . kg(-1) . min(-1)) was started. Spearman correlation coefficient and prediction probability were calculated for sedation levels with SE, RE, BIS, mean arterial blood pressure, and heart rate. The ability of the investigated parameters to distinguish between the anesthesia steps awake versus loss of response, awake versus anesthesia, anesthesia versus first reaction, and anesthesia versus extubation was analyzed with the prediction probability. RESULTS: SE correlates best with sedation levels, but no significant differences of the prediction probability values among SE, RE, and BIS were found. The prediction probability for all investigated steps of anesthesia did not show significant differences among SE, RE, and BIS. SE, RE, and BIS were superior to mean arterial blood pressure and heart rate. CONCLUSION: SE, RE, and BIS revealed similar information about the level of sedation and allowed the authors to distinguish between different steps of anesthesia. Both monitors provided useful additional information for the anesthesiologist.

AB - BACKGROUND: Different analytical concepts were introduced to quantify the changes of the electroencephalogram. The Datex-Ohmeda S/5 Entropy Module (Datex-Ohmeda Division, Instrumentarium Corp., Helsinki, Finland) was the first commercial monitor based on the entropy generating two indices, the state entropy (SE) and the response entropy (RE). The aim of the current study was to compare the accuracy of SE and RE with the Bispectral Index(R) monitor (BIS(R); Aspect Medical Systems, Newton, MA) during propofol-remifentanil anesthesia. METHODS: The authors investigated 20 female patients during minor gynecologic surgery. SE, RE, BIS, mean arterial blood pressure, heart rate, and sedation level were recorded every 20 s during stepwise increase (target-controlled infusion, 0.5 microg/ml) of propofol until the patients lost response. Five minutes after loss of response, remifentanil infusion (0.4 microg . kg(-1) . min(-1)) was started. Spearman correlation coefficient and prediction probability were calculated for sedation levels with SE, RE, BIS, mean arterial blood pressure, and heart rate. The ability of the investigated parameters to distinguish between the anesthesia steps awake versus loss of response, awake versus anesthesia, anesthesia versus first reaction, and anesthesia versus extubation was analyzed with the prediction probability. RESULTS: SE correlates best with sedation levels, but no significant differences of the prediction probability values among SE, RE, and BIS were found. The prediction probability for all investigated steps of anesthesia did not show significant differences among SE, RE, and BIS. SE, RE, and BIS were superior to mean arterial blood pressure and heart rate. CONCLUSION: SE, RE, and BIS revealed similar information about the level of sedation and allowed the authors to distinguish between different steps of anesthesia. Both monitors provided useful additional information for the anesthesiologist.

M3 - SCORING: Zeitschriftenaufsatz

VL - 101

SP - 1283

EP - 1290

JO - ANESTHESIOLOGY

JF - ANESTHESIOLOGY

SN - 0003-3022

IS - 6

M1 - 6

ER -