Comparative evaluation of Narcotrend, Bispectral Index, and classical electroencephalographic variables during induction, maintenance, and emergence of a propofol/remifentanil anesthesia.

Standard

Comparative evaluation of Narcotrend, Bispectral Index, and classical electroencephalographic variables during induction, maintenance, and emergence of a propofol/remifentanil anesthesia. / Schmidt, Gunter Niels; Bischoff, Petra; Standl, Thomas; Lankenau, Gunnar; Hilbert, Mathias; Jochen, Schulte Am Esch.

In: ANESTH ANALG, Vol. 98, No. 5, 5, 2004, p. 1346-1353.

Research output: SCORING: Contribution to journalSCORING: Journal articleResearchpeer-review

Harvard

APA

Vancouver

Bibtex

@article{57706962ed744a898314602625e297ae,
title = "Comparative evaluation of Narcotrend, Bispectral Index, and classical electroencephalographic variables during induction, maintenance, and emergence of a propofol/remifentanil anesthesia.",
abstract = "In the present study, we sought to compare the abilities of Narcotrend (NT) with the Bispectral Index (BIS) electroencephalographic system to monitor depth of consciousness immediately before induction of anesthesia until extubation during a standardized anesthetic. We investigated 26 patients undergoing laminectomy. Investigated states of anesthesia were: awake, loss of response, loss of eyelash reflex, steady-state anesthesia, first reaction, and extubation during emergence. NT, BIS, spectral edge frequency, median frequency, relative power in delta, theta, alpha, beta, and hemodynamics were recorded simultaneously. The ability of all variables to distinguish between awake versus loss of response, awake versus loss of eyelash reflex, awake versus steady-state anesthesia, steady-state anesthesia versus first reaction and extubation were analyzed with the prediction probability. Effects of remifentanil during propofol infusion were investigated with Friedman's and post hoc with Wilcoxon's test. Only NT and BIS were able to distinguish all investigated states accurately with a prediction probability >0.95. After start of remifentanil infusion, only hemodynamics changed statistically significantly (P <0.05). NT and BIS are more reliable indicators for the assessment of anesthetic states than classical electroencephalographic variables and hemodynamics, whereas the analgesic potency of depth of anesthesia could not be detected by NT and BIS. IMPLICATIONS: The modern electroencephalographic monitoring systems Narcotrend and Bispectral Index are more reliable indicators for the assessment of anesthetic states than classical electroencephalographic and hemodynamic variables to predict anesthetic conditions from before induction of anesthesia until extubation during a standardized anesthetic regime with propofol and remifentanil. The analgesic potency of depth of anesthesia could not be detected by Narcotrend and Bispectral Index.",
author = "Schmidt, {Gunter Niels} and Petra Bischoff and Thomas Standl and Gunnar Lankenau and Mathias Hilbert and Jochen, {Schulte Am Esch}",
year = "2004",
language = "Deutsch",
volume = "98",
pages = "1346--1353",
journal = "ANESTH ANALG",
issn = "0003-2999",
publisher = "Lippincott Williams and Wilkins",
number = "5",

}

RIS

TY - JOUR

T1 - Comparative evaluation of Narcotrend, Bispectral Index, and classical electroencephalographic variables during induction, maintenance, and emergence of a propofol/remifentanil anesthesia.

AU - Schmidt, Gunter Niels

AU - Bischoff, Petra

AU - Standl, Thomas

AU - Lankenau, Gunnar

AU - Hilbert, Mathias

AU - Jochen, Schulte Am Esch

PY - 2004

Y1 - 2004

N2 - In the present study, we sought to compare the abilities of Narcotrend (NT) with the Bispectral Index (BIS) electroencephalographic system to monitor depth of consciousness immediately before induction of anesthesia until extubation during a standardized anesthetic. We investigated 26 patients undergoing laminectomy. Investigated states of anesthesia were: awake, loss of response, loss of eyelash reflex, steady-state anesthesia, first reaction, and extubation during emergence. NT, BIS, spectral edge frequency, median frequency, relative power in delta, theta, alpha, beta, and hemodynamics were recorded simultaneously. The ability of all variables to distinguish between awake versus loss of response, awake versus loss of eyelash reflex, awake versus steady-state anesthesia, steady-state anesthesia versus first reaction and extubation were analyzed with the prediction probability. Effects of remifentanil during propofol infusion were investigated with Friedman's and post hoc with Wilcoxon's test. Only NT and BIS were able to distinguish all investigated states accurately with a prediction probability >0.95. After start of remifentanil infusion, only hemodynamics changed statistically significantly (P <0.05). NT and BIS are more reliable indicators for the assessment of anesthetic states than classical electroencephalographic variables and hemodynamics, whereas the analgesic potency of depth of anesthesia could not be detected by NT and BIS. IMPLICATIONS: The modern electroencephalographic monitoring systems Narcotrend and Bispectral Index are more reliable indicators for the assessment of anesthetic states than classical electroencephalographic and hemodynamic variables to predict anesthetic conditions from before induction of anesthesia until extubation during a standardized anesthetic regime with propofol and remifentanil. The analgesic potency of depth of anesthesia could not be detected by Narcotrend and Bispectral Index.

AB - In the present study, we sought to compare the abilities of Narcotrend (NT) with the Bispectral Index (BIS) electroencephalographic system to monitor depth of consciousness immediately before induction of anesthesia until extubation during a standardized anesthetic. We investigated 26 patients undergoing laminectomy. Investigated states of anesthesia were: awake, loss of response, loss of eyelash reflex, steady-state anesthesia, first reaction, and extubation during emergence. NT, BIS, spectral edge frequency, median frequency, relative power in delta, theta, alpha, beta, and hemodynamics were recorded simultaneously. The ability of all variables to distinguish between awake versus loss of response, awake versus loss of eyelash reflex, awake versus steady-state anesthesia, steady-state anesthesia versus first reaction and extubation were analyzed with the prediction probability. Effects of remifentanil during propofol infusion were investigated with Friedman's and post hoc with Wilcoxon's test. Only NT and BIS were able to distinguish all investigated states accurately with a prediction probability >0.95. After start of remifentanil infusion, only hemodynamics changed statistically significantly (P <0.05). NT and BIS are more reliable indicators for the assessment of anesthetic states than classical electroencephalographic variables and hemodynamics, whereas the analgesic potency of depth of anesthesia could not be detected by NT and BIS. IMPLICATIONS: The modern electroencephalographic monitoring systems Narcotrend and Bispectral Index are more reliable indicators for the assessment of anesthetic states than classical electroencephalographic and hemodynamic variables to predict anesthetic conditions from before induction of anesthesia until extubation during a standardized anesthetic regime with propofol and remifentanil. The analgesic potency of depth of anesthesia could not be detected by Narcotrend and Bispectral Index.

M3 - SCORING: Zeitschriftenaufsatz

VL - 98

SP - 1346

EP - 1353

JO - ANESTH ANALG

JF - ANESTH ANALG

SN - 0003-2999

IS - 5

M1 - 5