Combining B-mode ultrasound with pulsed wave Doppler for the assessment of tubal patency.

Standard

Combining B-mode ultrasound with pulsed wave Doppler for the assessment of tubal patency. / Kleinkauf-Houcken, A; Hüneke, Bernd; Lindner, C; Braendle, W.

In: HUM REPROD, Vol. 12, No. 11, 11, 1997, p. 2457-2460.

Research output: SCORING: Contribution to journalSCORING: Journal articleResearchpeer-review

Harvard

Kleinkauf-Houcken, A, Hüneke, B, Lindner, C & Braendle, W 1997, 'Combining B-mode ultrasound with pulsed wave Doppler for the assessment of tubal patency.', HUM REPROD, vol. 12, no. 11, 11, pp. 2457-2460. <http://www.ncbi.nlm.nih.gov/pubmed/9436684?dopt=Citation>

APA

Vancouver

Kleinkauf-Houcken A, Hüneke B, Lindner C, Braendle W. Combining B-mode ultrasound with pulsed wave Doppler for the assessment of tubal patency. HUM REPROD. 1997;12(11):2457-2460. 11.

Bibtex

@article{e5b7ccae7c7f4589b1a13ed7be2904bd,
title = "Combining B-mode ultrasound with pulsed wave Doppler for the assessment of tubal patency.",
abstract = "This study was conducted to determine whether the additional use of pulsed wave Doppler improves the diagnostic capacity in assessing tubal patency by hysterosalpingo contrast sonography (HyCoSy). A total of 210 women with a history of infertility were included in this study. HyCoSy was performed after intrauterine injection of Echovist 200. For the assessment of tubal patency B-mode scanning and pulsed wave Doppler ultrasound were performed in the proximal and distal tubal segments. With the combined sonographic procedure 297 tubes (74%) were rated patent, 35 (8%) incompletely obstructed and 70 (18%) completely obstructed. A total of 252 tubes were additionally examined by laparoscopy for reference purposes. Concordant results for both methods were found in 92% of tubes, nine had been rated false negative and 10 tubes appeared to have been rated false positive. The combined sonographic specificity was found to be 85% with a sensitivity of 95%. Peritubal adhesions detected by laparoscopy were found to be the reason for false positive sonographic results in 60% of cases. In conclusion, the combined B-mode and pulsed wave Doppler examination appears to be a non-invasive and low-cost test for the assessment of tubal patency, which should be performed during diagnostic work-up for infertility.",
author = "A Kleinkauf-Houcken and Bernd H{\"u}neke and C Lindner and W Braendle",
year = "1997",
language = "Deutsch",
volume = "12",
pages = "2457--2460",
journal = "HUM REPROD",
issn = "0268-1161",
publisher = "Oxford University Press",
number = "11",

}

RIS

TY - JOUR

T1 - Combining B-mode ultrasound with pulsed wave Doppler for the assessment of tubal patency.

AU - Kleinkauf-Houcken, A

AU - Hüneke, Bernd

AU - Lindner, C

AU - Braendle, W

PY - 1997

Y1 - 1997

N2 - This study was conducted to determine whether the additional use of pulsed wave Doppler improves the diagnostic capacity in assessing tubal patency by hysterosalpingo contrast sonography (HyCoSy). A total of 210 women with a history of infertility were included in this study. HyCoSy was performed after intrauterine injection of Echovist 200. For the assessment of tubal patency B-mode scanning and pulsed wave Doppler ultrasound were performed in the proximal and distal tubal segments. With the combined sonographic procedure 297 tubes (74%) were rated patent, 35 (8%) incompletely obstructed and 70 (18%) completely obstructed. A total of 252 tubes were additionally examined by laparoscopy for reference purposes. Concordant results for both methods were found in 92% of tubes, nine had been rated false negative and 10 tubes appeared to have been rated false positive. The combined sonographic specificity was found to be 85% with a sensitivity of 95%. Peritubal adhesions detected by laparoscopy were found to be the reason for false positive sonographic results in 60% of cases. In conclusion, the combined B-mode and pulsed wave Doppler examination appears to be a non-invasive and low-cost test for the assessment of tubal patency, which should be performed during diagnostic work-up for infertility.

AB - This study was conducted to determine whether the additional use of pulsed wave Doppler improves the diagnostic capacity in assessing tubal patency by hysterosalpingo contrast sonography (HyCoSy). A total of 210 women with a history of infertility were included in this study. HyCoSy was performed after intrauterine injection of Echovist 200. For the assessment of tubal patency B-mode scanning and pulsed wave Doppler ultrasound were performed in the proximal and distal tubal segments. With the combined sonographic procedure 297 tubes (74%) were rated patent, 35 (8%) incompletely obstructed and 70 (18%) completely obstructed. A total of 252 tubes were additionally examined by laparoscopy for reference purposes. Concordant results for both methods were found in 92% of tubes, nine had been rated false negative and 10 tubes appeared to have been rated false positive. The combined sonographic specificity was found to be 85% with a sensitivity of 95%. Peritubal adhesions detected by laparoscopy were found to be the reason for false positive sonographic results in 60% of cases. In conclusion, the combined B-mode and pulsed wave Doppler examination appears to be a non-invasive and low-cost test for the assessment of tubal patency, which should be performed during diagnostic work-up for infertility.

M3 - SCORING: Zeitschriftenaufsatz

VL - 12

SP - 2457

EP - 2460

JO - HUM REPROD

JF - HUM REPROD

SN - 0268-1161

IS - 11

M1 - 11

ER -