Clinical evaluation and computed tomography scan analysis of screw tracts after percutaneous insertion of pedicle screws in the lumbar spine.
Standard
Clinical evaluation and computed tomography scan analysis of screw tracts after percutaneous insertion of pedicle screws in the lumbar spine. / Wiesner, L; Kothe, R; Schulitz, K P; Rüther, Wolfgang.
In: SPINE, Vol. 25, No. 5, 5, 2000, p. 615-621.Research output: SCORING: Contribution to journal › SCORING: Journal article › Research › peer-review
Harvard
APA
Vancouver
Bibtex
}
RIS
TY - JOUR
T1 - Clinical evaluation and computed tomography scan analysis of screw tracts after percutaneous insertion of pedicle screws in the lumbar spine.
AU - Wiesner, L
AU - Kothe, R
AU - Schulitz, K P
AU - Rüther, Wolfgang
PY - 2000
Y1 - 2000
N2 - An examination of the accuracy of percutaneous pedicle screw placement in the lumbar spine. Using computed tomography scan analysis after implant removal, the screw tracts could be analyzed regarding the degree and direction of screw dislocation.
AB - An examination of the accuracy of percutaneous pedicle screw placement in the lumbar spine. Using computed tomography scan analysis after implant removal, the screw tracts could be analyzed regarding the degree and direction of screw dislocation.
M3 - SCORING: Zeitschriftenaufsatz
VL - 25
SP - 615
EP - 621
JO - SPINE
JF - SPINE
SN - 0362-2436
IS - 5
M1 - 5
ER -