Benefit of pulmonary vein isolation guided by loss of pace capture on the ablation line: results from a prospective 2-center randomized trial
Standard
Benefit of pulmonary vein isolation guided by loss of pace capture on the ablation line: results from a prospective 2-center randomized trial. / Steven, Daniel; Sultan, Arian; Reddy, Vivek; Luker, Jakob; Altenburg, Manuel; Hoffmann, Boris; Rostock, Thomas; Servatius, Helge; Stevenson, William G; Willems, Stephan; Michaud, Gregory F.
In: J AM COLL CARDIOL, Vol. 62, No. 1, 02.07.2013, p. 44-50.Research output: SCORING: Contribution to journal › SCORING: Journal article › Research › peer-review
Harvard
APA
Vancouver
Bibtex
}
RIS
TY - JOUR
T1 - Benefit of pulmonary vein isolation guided by loss of pace capture on the ablation line: results from a prospective 2-center randomized trial
AU - Steven, Daniel
AU - Sultan, Arian
AU - Reddy, Vivek
AU - Luker, Jakob
AU - Altenburg, Manuel
AU - Hoffmann, Boris
AU - Rostock, Thomas
AU - Servatius, Helge
AU - Stevenson, William G
AU - Willems, Stephan
AU - Michaud, Gregory F
N1 - Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
PY - 2013/7/2
Y1 - 2013/7/2
N2 - OBJECTIVES: This study was conducted to determine if an additional procedural endpoint of unexcitability (UE) to pacing along the ablation line reduces recurrence of atrial fibrillation (AF) or atrial tachycardia (AT) after radiofrequency catheter ablation.BACKGROUND: AF/AT recurrence is common after pulmonary vein isolation (PVI).METHODS: We included 102 patients from 2 centers (age 63 ± 10 years; 33 women; left atrium 38 ± 7 mm; left ventricular ejection fraction 61 ± 6%) with symptomatic paroxysmal AF. A 3-dimensional mapping system and circumferential mapping catheter were used in all patients for PVI. In group 1 (n = 50), the procedural endpoint was bidirectional block across the ablation line. In group 2 (n = 52), additional UE to bipolar pacing at an output of 10 mA and 2-ms pulse width was required. The primary endpoint was freedom from any AF/AT (>30 s) after discontinuation of antiarrhythmic drugs.RESULTS: Procedural endpoints were successfully achieved in all patients. Procedure duration was significantly longer in group 2 (185 ± 58 min vs. 139 ± 57 min; p < 0.001); however, fluoroscopy times were not different (23 ± 9 min vs. 23 ± 9 min; p = 0.49). After a follow-up of 12 months in all patients, 26 patients (52%) in group 1 versus 43 (82.7%) in group 2 were free from any AF/AT (p = 0.001) after a single procedure. No major complications occurred.CONCLUSIONS: The use of pacing to ensure UE along the PVI line markedly improved near-term single-procedure success, compared with demonstration of bidirectional block alone. This additional endpoint significantly improved patient outcomes after PVI. (Unexcitability Along the Ablation as an Endpoint for Atrial Fibrillation Ablation; NCT01724437).
AB - OBJECTIVES: This study was conducted to determine if an additional procedural endpoint of unexcitability (UE) to pacing along the ablation line reduces recurrence of atrial fibrillation (AF) or atrial tachycardia (AT) after radiofrequency catheter ablation.BACKGROUND: AF/AT recurrence is common after pulmonary vein isolation (PVI).METHODS: We included 102 patients from 2 centers (age 63 ± 10 years; 33 women; left atrium 38 ± 7 mm; left ventricular ejection fraction 61 ± 6%) with symptomatic paroxysmal AF. A 3-dimensional mapping system and circumferential mapping catheter were used in all patients for PVI. In group 1 (n = 50), the procedural endpoint was bidirectional block across the ablation line. In group 2 (n = 52), additional UE to bipolar pacing at an output of 10 mA and 2-ms pulse width was required. The primary endpoint was freedom from any AF/AT (>30 s) after discontinuation of antiarrhythmic drugs.RESULTS: Procedural endpoints were successfully achieved in all patients. Procedure duration was significantly longer in group 2 (185 ± 58 min vs. 139 ± 57 min; p < 0.001); however, fluoroscopy times were not different (23 ± 9 min vs. 23 ± 9 min; p = 0.49). After a follow-up of 12 months in all patients, 26 patients (52%) in group 1 versus 43 (82.7%) in group 2 were free from any AF/AT (p = 0.001) after a single procedure. No major complications occurred.CONCLUSIONS: The use of pacing to ensure UE along the PVI line markedly improved near-term single-procedure success, compared with demonstration of bidirectional block alone. This additional endpoint significantly improved patient outcomes after PVI. (Unexcitability Along the Ablation as an Endpoint for Atrial Fibrillation Ablation; NCT01724437).
KW - Aged
KW - Atrial Fibrillation/diagnosis
KW - Cardiac Pacing, Artificial/methods
KW - Catheter Ablation/instrumentation
KW - Female
KW - Follow-Up Studies
KW - Humans
KW - Male
KW - Middle Aged
KW - Pilot Projects
KW - Prospective Studies
KW - Pulmonary Veins/physiology
KW - Treatment Outcome
U2 - 10.1016/j.jacc.2013.03.059
DO - 10.1016/j.jacc.2013.03.059
M3 - SCORING: Journal article
C2 - 23644091
VL - 62
SP - 44
EP - 50
JO - J AM COLL CARDIOL
JF - J AM COLL CARDIOL
SN - 0735-1097
IS - 1
ER -